Parameter
Description
Range
Default
1
Key
1 = Zero key
2 = Tare key
3 = Gross/net key
4 = Function 1 key
5 = Function 2 key
6 = Function 3 key
-
2
Duration of key press
0 = Short press
1 = Long press
0 (short press)
Example
Command
Answer
Description
S01;
Select unit 1
FPL?;
"0476003F088100000000000000000000"CRLF
Get current display buffer
FPL1;
0 CRLF
Simulate short press of the zero key
FPL2,0;
0 CRLF
Simulate short press of the tare key
FPL3,1;
0 CRLF
Simulate long press of the gross/net key (enter
setup)
21.3.22
IAD: Scale Build
Set the scale build parameters including max1,e1,max2,e2,decimal point etc.
General
No. of parameters
7
Save changes
With
TDD1
Increment Trade Counter
Yes
Parameter Details
Parameter
Description
Range
Default
1
Range
1 .. 2
1
2
Maximum Load
(max1 or max2)
100 .. 999999
Range 1: 3000
Range 2: 6000
3
Number of right side digits
(decimal point position)
0 .. 5
0
4
Resolution (e1 or e2)
1 = 1
2 = 2
3 = 5
4 = 10
5 = 20
6 = 50
7 = 100
Range 1: 1
Range 2: 2
5
x10 mode
0 = Off
1 = On
0
6
Additive Tare
0 .. full scale
0
7
Sense line check
0 = Off
1 = On
1
Note
The full scale weight of the instrument is set to nominal load 1 for single range
installations, and nominal load 2 for dual-range and dual-interval installations. In
single range installations nominal load 2 is not used.
Example
135
C500-600-2.0.3
Содержание C500 series
Страница 1: ...C500 Series Digital Indicator Reference Manual ...
Страница 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Страница 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Страница 120: ...Select C500 and click create Enter the module name description and IP address then click change 115 C500 600 2 0 3 ...
Страница 123: ...118 C500 600 2 0 3 ...
Страница 182: ...177 C500 600 2 0 3 ...