FLOORING AND HEARTH MATERIAL SELECTION
The temperature in front of the fire (200-350 mm x 400 mm wide) can reach up to 40 °C above ambient, therefore
material selection is important. Some guidelines are detailed below. For example, vinyl planks are often only rated
for ambient temperatures. Consequently, the heater would not be suitable for installation directly on that flooring
type.
E
D
F
F
G
I
50 mm (min)
H
C
A
B
Non-combustible
hearth
B
A
Front
Side view
Dim.
Description
Non-combustible materials or
materials rated to 60 °C or higher
above ambient
Materials rated to a
maximum of 50 °C
above ambient
Unrated materials,
anything up to 20 °C
above ambient
A
Overhang
No restriction as long as materials
within 400 mm to the side (D) are of
the same rating
•
Not suitable if B is under 250 mm
•
No restrictions if B is greater than 1000 mm
•
If B is 300-1000, refer page 9
B
Clearance above
50 mm min.
100 mm min.
200 mm min
C
Side overhang
No restrictions
No restrictions if D is greater than 400 mm
D
Side clearance
50 mm min.
50 mm min.
100 mm min.
E
In front
No restrictions
150 mm max.
100 mm max.
F
Clearance to floor
No restrictions
150 mm min.
240 mm min.
G
Hearth depth
No restrictions
400 mm min. of non-
combustible material
450 mm min. of non-
combustible material
H
Directly on floor
No restrictions
Not suitable for heat sensitive materials
I
Flue clearance
25 mm min.
50 mm min.
The shaded cells above denote measurements A, B, C, and D. These figures are dependent on each other and the type
of installation. These dimensions may be refined with some specific calculations. These calculations are based on figures
obtained during in-house temperature testing. For more information refer to the next page.
Even if a material is rated above 60 °C it may still be subject to deterioration when exposed to heat cycles. Always
refer to the materials supplier for suitability. The temperatures given assume the heater is operating in a room
temperature of 25 °C or less. Operation in higher ambient temperatures may result in higher surface temperatures.
WARNING
RINNAI DOES NOT TAKE ANY RESPONSIBILITY FOR ANY DAMAGE OCCURRING
TO ANY ITEMS INSTALLED IN THE VICINITY OF THE HEATER.
GENERAL INSTALLATION INFORMATION