background image

This appliance shall be installed in accordance with:

•  Manufacturer’s Installation Instructions

•  Current  AS/NZS 3000 

 

•  Local Regulations and Municipal Building Codes including local OH&S requirements

This appliance must be installed, maintained and removed by an Authorised Person.
For continued safety of this appliance it must be installed and maintained in 

accordance with the manufacturers instructions.

HIGH

MID

LOW

HEAT

DRY

FAN

COLL

TIMER

SLEEP

SWING

F

C

Operation Manual

Portable Room Air Conditioner

Models: RPC35WA and RPC41WA 

Содержание RPC35WA

Страница 1: ...ncluding local OH S requirements This appliance must be installed maintained and removed by an Authorised Person For continued safety of this appliance it must be installed and maintained in accordance with the manufacturers instructions HIGH MID LOW HEAT DRY FAN COLL TIMER SLEEP SWING F C Operation Manual Portable Room Air Conditioner Models RPC35WA and RPC41WA ...

Страница 2: ... AC OIM BEFORE PROCEEDING WITH THE OPERATION OF YOUR NEW RINNAI PORTABLE ROOM AIR CONDITIONER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE REQUIREMENTS FEATURES AND OPERATION OF YOUR NEW APPLIANCE ...

Страница 3: ...ation Remote Control 8 COOL 8 DRY Dehumidifying 9 FAN 9 Advanced Functions 9 Setting the Clock 9 Advanced Functions Remote Control 9 On Timer 9 OFF Timer 10 SLEEP Function 10 SWING Function 10 Care Maintenance 11 General Maintenance 11 Cleaning the air filter 11 Save A Service Call 12 When to Call for Service 12 Installation 13 Location 13 Duct assembly 13 Installation 14 Exhaust Ducting Options 1...

Страница 4: ...pabilities to sleep directly in front of this appliance DO NOT allow children to post articles into the louvres of the appliance DO NOT use power boards or double adaptors with this appliance DO NOT coil or bundle the electric cord to reduce it s length as overheating of the cord may occur which could result in a fire hazard The flexible cord and plug must not be modified If the cord or plug are d...

Страница 5: ...placement Supplier warranty claims for Rinnai products or services must be made by contacting Rinnai Australia Contact details are on the back of this document The following exclusions may cause the warranty to become void and may result in a service charge and costs of parts if required 1 Accidental damage and acts of God 2 Failure due to abuse or misuse improper maintenance failure to maintain o...

Страница 6: ... located behind grill 11 Swivel casters x4 12 Drain tray outlet 13 1 2m flexible 2 pin cord 220 240V 50Hz 10A 14 Adjustable window slide kit 15 Window exhaust duct window adapter 16 Exhaust duct extends to 1 8M 17 Duct to appliance adaptor 18 Wall exhaust adaptor 19 Wall exhaust terminal 20 Condensate drain hose HIGH MID LOW HEAT DRY FAN COLL TIMER SLEEP SWING F C 88 8 8 A P OFF ON 8 8 C MO DE CLO...

Страница 7: ...RIES Insert batteries before using the remote control The battery type used are 2x AAA 1 5 V NOTE If the LCD screen of the remote control starts to fade or fails to transmit replace the batteries When changing batteries ensure that the and terminals of the batteries are installed correctly REMOTE CONTROL CRADLE For convenience a slide in cradle is provided for fixing the remote control to a wall I...

Страница 8: ...utton 28 2 Press the mode button 24 until the DRY mode indicator is illuminated 3 Use temperature buttons 26 to select the desired temperature 16 C to 32 C 4 Press the On Off button 28 FAN 1 Press the On Off button 28 2 Press the mode button 24 until the FAN mode indicator is illuminated 3 Use fan speed buttons 22 to select the desired fan speed LOW MED or HIGH 4 Press the On Off button 28 NOTE Th...

Страница 9: ...nctions can be used the clock must be set SETTING THE CLOCK 1 Press and hold the CLOCK button 33 for five seconds the clock digits will begin to flash 2 Use the timer clock adjustment buttons to set the current time 3 When the desired time is reached press the CLOCK button 33 to lock in the time NOTE Holding down a button for approximately five seconds will increase the speed at which the time cha...

Страница 10: ...ppliance to turn OFF at a specific time then the use of a set OFF timer will allow the SLEEP timer to be over ridden and the appliance will turned OFF 2 Press the SLEEP button 36 at any time to cancel the SLEEP function operation 3 Press the On Off button 34 to stop operation SWING FUNCTION The swing function allows adjustment of the air flow by controlling the cool air outlet louvre in either a c...

Страница 11: ...om the power supply 1 Remove the grills To remove the Room Air Intake Grill 9 pull down on the top tab and un clip the grill To remove the Lower Air Intake Grill 10 use a Philips head screw driver to remove the securing screw and un clip the grill 2 Un clip the filters from each of the grills Clean the filters with a vacuum cleaner or with warm water If dirt is difficult to remove wash the filter ...

Страница 12: ...re blocked Clean air filters The set temperature is too high Adjust the set temperature to a lower temperature Drafts from open windows and doors Close windows and doors in the area you want to be cooled Other heat sources in the room Remove or turn off heat sources Cooling space too big Operate the appliance within the required cooling capacity Too noisy or vibrating Operating surface not level M...

Страница 13: ...unt when determining the location that the appliance will be operated in DUCT ASSEMBLY 1 Place the Duct to Unit Adaptor 17 over the Exhaust Outlet 5 push it downwards to ensure it engages the Exhaust Outlet tabs 2 Screw one end of the Exhaust Duct 16 into the Duct to Unit Adaptor 17 3 On the other end of the Exhaust Duct 16 fix either the Window Exhaust Duct Adaptor 15 or the Wall Exhaust Adaptor ...

Страница 14: ... aspects of this installation procedure for certain window types Minimum and maximum horizontal vertical window opening dimensions 1 Once a suitable window has been chosen fit the Adjustable Slider Kit 14 into the window areas and fix the length of the kit using the supplied slide lock nut and bolt NOTE It is recommended to place a length of foam draft sealing strip along the top and bottom edges ...

Страница 15: ...be resumed To do this 1 Place shallow tray such as an oven baking tray or similar with at least a 1 litre volume under Drain Tray Outlet 12 2 Remove the plug from Drain Tray Outlet 12 and drain out the condensate water once the condensate is drained replace the plug the appliance will now be able to then resume operation FIXED CONDENSATE DRAINAGE HOSE As an alternative to using the appliances inte...

Страница 16: ...all our National Help Line Rinnai recommends that this appliance be serviced every 1 years Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 Product Sales and Service National Phone 1300 555 545 Fax 1300 555 655 Technical Helpline and Spare Parts National Mon Fri 8am 5 30pm EST Phone 1300 555 545 Fax 1300 300 141 Cost of a local call higher from mobile or publi...