![Rinnai REU-V1616WF Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/rinnai/reu-v1616wf/reu-v1616wf_service-manual_1463120042.webp)
Infinity REU-V1616WF
- 37 -
Issue 1 -
21/11/03
©Rinnai
• Manifold (Assembly)
c. Remove the combustion chamber Front panel (6
screws).
d. Remove screws from the burner unit (2 screws)
e. Take out the burner unit.
f. Remove the damper. (3 screws).
7) Removal of the Gas Control
a. Remove the manifold. Refer 6.
b. Take out the back pressure tube.
c. Remove gas connection and gas control screws. (4
screws).
d. Remove the gas control (1 screw).
e. Take out the gas control from body and remove
connector of modulation valve, (Pink-Pink).
• Main valve (Pink-Blk).
• Solenoid valve 1 (Blue-Blk) and solenoid valve 2
(Ylw-Blk).
• Gas Control (Assy).
Содержание REU-V1616WF
Страница 19: ...Infinity REU V1616WF 14 Issue 1 21 11 03 Rinnai 7 Cutaway Diagram ...
Страница 20: ...Infinity REU V1616WF 15 Issue 1 21 11 03 Rinnai 8 Operational Flow Chart ...
Страница 25: ...Infinity REU V1616WF 20 Issue 1 21 11 03 Rinnai 12 Wiring Diagram ...
Страница 47: ...Infinity REU V1616WF 42 Issue 1 21 11 03 Rinnai 20 Exploded Diagram ...
Страница 48: ...Infinity REU V1616WF 43 Issue 1 21 11 03 Rinnai ...
Страница 49: ...Infinity REU V1616WF 44 Issue 1 21 11 03 Rinnai ...
Страница 50: ...Infinity REU V1616WF 45 Issue 1 21 11 03 Rinnai ...
Страница 54: ...Infinity REU V1616WF Issue 1 21 11 03 Rinnai Notes ...