64
Rinnai I
-
Series Condensing Boiler Combi Manual
Devices such as the room thermostat, outdoor temperature sensor, zones pumps, and relay
controls are connected to the boiler PC Board.
□
Confirm that the electricity is supplied from a 120 VAC, 60 Hz power source and is in a
properly grounded circuit.
□
Confirm that an extension cord or adapter plug has NOT been used with the boiler.
□
Confirm connection terminals are connected correctly.
PC Board
❼
❻
❹
❺
❽
Item #
Connection Item
Note
Internal Pump Connection
120 VAC
External Pump Connection 2
120 VAC, Max 2.0 A
External Pump Connection 1
120 VAC, Max 2.0 A
T/T 1 Connection
T/T 2 Connection
LWCO (High Limit or Other
Safety Switch)
Included Jumper
from Factory
Outdoor Temperature Sensor
24V AC for External Output
Max 0.7 A
❶
❷
❸
❹
❺
❻
❼
❽
❶
❷
❸
•
Rinnai recommends the use of spade connectors or
similar components for wiring to the screw terminals.
•
Ensure that the insulation of the wire is not exposed
to contact any other components besides the
terminal.
•
If exposed wiring contacts to any other exposed
wiring or metal components, an electrical short may
occur and cause damage to the PCB or other
connected components.
•
Use proper size of screwdriver for preventing the
screw on the terminal from breaking.
•
Do not use an electric or torque screwdriver for
wiring on the PC Board.
•
Wiring should pass through the grommets provided
at the bottom of the boiler.
•
Use proper diameter and size of wiring.
CAUTION
Содержание I Series
Страница 124: ...124 Rinnai I Series Condensing Boiler Combi Manual ...
Страница 125: ...Rinnai I Series Condensing Boiler Combi Manual 125 ...
Страница 134: ...134 Rinnai I Series Condensing Boiler Combi Manual ...
Страница 135: ...Rinnai I Series Condensing Boiler Combi Manual 135 ...
Страница 136: ...136 Rinnai I Series Condensing Boiler Combi Manual 800000111 3 2019 ...