Rinnai HINRP26M Скачать руководство пользователя страница 1

Models

System

Indoor

Outdoor

HSNRP26 HINRP26M HONRP26
HSNRP35 HINRP35M HONRP35
HSNRP50 HINRP50M HONRP50
HSNRP60 HINRP60M HONRP60
HSNRP70 HINRP70M HONRP70
HSNRP80 HINRP80

HONRP80

Installation guide

Pro Series High Wall Split Heat Pump / Air Conditioner

Содержание HINRP26M

Страница 1: ...door HSNRP26 HINRP26M HONRP26 HSNRP35 HINRP35M HONRP35 HSNRP50 HINRP50M HONRP50 HSNRP60 HINRP60M HONRP60 HSNRP70 HINRP70M HONRP70 HSNRP80 HINRP80 HONRP80 Installation guide Pro Series High Wall Split Heat Pump Air Conditioner ...

Страница 2: ...sed person Warning Improper installation adjustment alteration service and maintenance can cause property damage personal injury or loss of life For more information about buying using and servicing of Rinnai appliances call 0800 RINNAI 0800 746 624 Rinnai New Zealand Limited 105 Pavilion Drive Mangere Auckland PO Box 53177 Auckland Airport Auckland 2150 Phone 09 257 3800 Email info rinnai co nz W...

Страница 3: ...itioning and clearances indoor unit 8 Positioning and clearances outdoor unit 9 Indoor installation 10 Outdoor installation 13 Refrigerant piping connection 15 Evacuation 17 Electrical and gas leak checks 18 Test run 19 Installation checklist 20 Appendix 1 Mounting plate dimensions 21 Appendix 2 Error code summary 22 Contents ...

Страница 4: ...lass 1 electrical appliance Make sure the live wire neutral wire and earth wire in the power socket are properly connected Inadequate or incorrect electrical connections may cause fire or electric shock The yellow green wire in the air conditioner is the earthing wire which cannot be used for any other purpose Improper earthing may cause electric shock The unit must be earthed in accordance with l...

Страница 5: ...zes Please ensure that these room sizes are adhered to for standard installations up to 10 m pipe length If larger refrigerant charges than standard are used then please consult AS NZS 60335 2 40 to determine the safe minimum floor area for the installation Make sure the area has been made safe by having suitable ventilation and is free from ignition sources before charging or releasing the charge...

Страница 6: ...et Gross Weight kg 8 0 10 3 8 5 11 1 8 5 11 1 11 1 14 4 11 1 14 4 13 3 17 0 13 3 17 0 Cooling Heating 2 0kW Outdoor 2 6kW Outdoor 3 5kW Outdoor 5 0kW Outdoor 6 0kW Outdoor 7 0kW Outdoor 8 0kW Outdoor 54 57 57 65 66 65 67 53 55 5 55 5 59 5 59 5 61 61 Dimension W x H x D 765x303x555 805x330x554 805x330x554 890x342x673 890x342x673 890x342x673 890x342x673 Packing W x H x D 887x337x610 915x370x615 915x...

Страница 7: ...e Signal cable Refrigerant piping Remote Remote holder Outdoor unit power cable Select installation location Determine wall hole position Attach mounting plate Drill hole in wall Connect piping Connect wiring Prepare drain hose Wrap pipe and cable Mount indoor unit 1 2 3 4 5 6 7 8 9 2000 mm 120 mm 150 mm 120 mm ...

Страница 8: ...be ample room for a hole for the signal cable and refrigerant piping that connects the indoor and outdoor units The default position for all piping is to the right side of the indoor unit while facing the unit However the unit can accommodate piping to the left and right Ensure the following 5 Good air circulation 5 Convenient drainage 5 Noise from the unit will not disturb others 5 Firm and solid...

Страница 9: ...cessive dust 6 Near an obstacle that will block the air inlets and outlets 6 Near animals or plants that will be harmed by hot air discharge 6 Where it will be exposed to sea wind salt spray as this will reduce durability Special considerations for extreme weather If the unit is exposed to strong prevailing winds install the unit so that the air outlet fan is at a 90 degree angle to the direction ...

Страница 10: ...is will ensure the water drains properly Place the protective wall cuff in the hole This protects the edges of the hole and will help seal it when the installation is finished Prepare refrigerant piping The refrigerant piping is inside an insulating sleeve which is attached to the back of the unit You must prepare the piping before passing it through the hole in the wall Based on the position of t...

Страница 11: ...les Before performing any electrical or wiring work turn off the mains power to the system All wiring must be performed in accordance with the wiring diagram located on the back of the indoor unit s front panel The signal cable enables communication between the indoor and outdoor units You must choose the right cable size before preparing it for connection The size of the power supply cable signal...

Страница 12: ...is hooked firmly by applying slight pressure to the left and right hand sides of the unit The unit should not move 4 Using even pressure push down on the bottom half of the unit Keep pushing down until the unit snaps onto hooks along the bottom of the mounting plate Check that the unit is firmly mounted If the refrigerant piping is already embedded in the wall do the following 1 Hook the top of th...

Страница 13: ...do the following Mark the positions for the four expansion bolts based on the model Pre drill holes for the expansion bolts Place a nut on the end of each expansion bolt Hammer the expansion bolts into the pre drilled holes Remove the nuts from the expansion bolts and place the outdoor unit on the bolts Put a washer on each expansion bolt then replace the nuts Using a wrench tighten each nut until...

Страница 14: ... strip the rubber jacket from both ends of the cable to reveal approximately 40 mm of the wires inside Strip the insulation from the ends of the wires Using a crimper crimp u lugs on the ends of the wires While crimping make sure to clearly distinguish the live wire from the other wires 2 Unscrew the electrical wiring cover and remove it 3 Unscrew the cable clamp below the terminal block and place...

Страница 15: ...Sheath the pipe with insulating material 3 Place flare nuts on both ends of the pipe Make sure they are facing in the right direction You can t put them on or change their direction after flaring 4 Remove PVC tape from ends of pipe when ready to perform flaring work 5 Clamp flare form on the end of the pipe The end of the pipe must extend beyond the edge of the flare form in accordance with the di...

Страница 16: ...use excessive torque excessive force can break the nut or damage the refrigerant piping Outer diam of pipe mm Tightening torque N m Flare dimension B mm Ø 6 35 Ø 0 25 18 20 180 200 kgf cm 8 4 8 7 0 33 0 34 Ø 9 52 Ø 0 375 32 39 320 390 kgf cm 13 2 13 5 0 52 0 53 Ø 12 7 Ø 0 5 49 59 490 590 kgf cm 16 2 16 5 0 64 0 65 Ø 16 Ø 0 63 57 71 570 710 kgf cm 19 2 19 7 0 76 0 78 Ø 19 Ø 0 75 67 101 670 1010 kgf...

Страница 17: ...se the low pressure side of the manifold gauge and turn off the vacuum pump 7 Wait five minutes then check that there has been no change in system pressure If there is a change in system pressure refer to gas leak checks on next page If there is no change unscrew the cap from the high pressure valve and using a hexagonal wrench open the valve by a quarter turn clockwise Listen for gas exiting the ...

Страница 18: ... visual detection and with a grounding resistance tester Grounding resistance must be less than 0 1 Ω During test run check for electrical leakage During the test run use a multimeter to perform a comprehensive electrical leakage test If electrical leakage is detected turn off the unit immediately and call a licensed electrician to find and resolve the cause of the leakage Gas leak checks There ar...

Страница 19: ...grounded 5 All electrical terminals properly covered 5 Indoor and outdoor units installed correctly 5 All pipe connections do not leak 5 Water drains properly from the drain hose 5 All piping is properly insulated 5 COOL function performs correctly 5 HEAT function performs correctly 5 Indoor unit louvres rotate properly 5 Indoor unit remote operates correctly During operation the pressure of the r...

Страница 20: ...xtension Condensation F Is the drainage secure Water leakage F Electric wires installed correctly No cooling or heating may cause electrical shock or fire F Wiring in accordance within the specifications Operation failure electrical fire F Inlets outlets of the indoor and outdoor unit free of any obstructions No cooling or heating F Are the stop valves open No cooling or heating F Are the pipes de...

Страница 21: ... 55 338 54 173 5 0 kW and 6 0 kW 7 0 kW and 8 0 kW 973 65 Left rear hole Right rear hole 65 527 165 106 247 139 37 48 318 48 29 Model D 65 Left rear hole Right rear hole 65 805 403 230 190 297 47 53 36 121 231 Model B The Pro Series mounting plates differ to those represented in the dimension diagrams below they look like this ...

Страница 22: ...or has short circuited eh 60 Indoor room temperature sensor T1 is in an open circuit or has short circuited eh 61 Evapourator coil temperature sensor T2 is in an open circuit or has short circuited ec 07 The outdoor fan speed is operating outside the normal range eh 0b Indoor PCB display board communication error eh 0c Refrigerant leak detected pc 00 IPM malfunction or IGBT over strong current pro...

Страница 23: ...sure protection pc 31 Low pressure protection pc ol Outdoor ambient temperature too low ph 90 Evapourator coil temperature over high protection ph 91 Evapourator coil temperature over low protection lc 01 Frequency limit caused by T3 lc 02 Frequency limit caused by TP lc 03 Frequency limit caused by over current lc 05 Frequency limit caused by voltage lc 06 Frequency limit caused by PFC LH 00 Freq...

Страница 24: ...Tel 0800 746 624 http www youtube com rinnainz http facebook com rinnainz Rinnai co nz Pro Series installation guide 14093 A I 01 22 ...