Rinnai DDSTAT234 Скачать руководство пользователя страница 1

Demand Duo commercial controller (DDSTAT234)

Programming guide

Programming setup for the following Rinnai commercial systems:

•  Demand Rapid with one INFINITY and a single pump
•  Demand Duo (DD400-1000) with a single pump
•  Demand Duo (DD400-1000) with two pumps
•  Demand Duo (DD400-1000) in a circulating ring main system with two pumps

Содержание DDSTAT234

Страница 1: ...rogramming guide ProgrammingsetupforthefollowingRinnaicommercialsystems DemandRapidwithoneINFINITYandasinglepump DemandDuo DD400 1000 withasinglepump DemandDuo DD400 1000 withtwopumps DemandDuo DD400 1000 inacirculatingringmainsystemwithtwopumps ...

Страница 2: ...and repair shall be carried out only by authorised personnel Warning Improper installation adjustment alteration service and maintenance can cause property damage personal injury or loss of life For more information about buying using and servicing of Rinnai appliances call 0800 RINNAI 0800 746 624 Rinnai New Zealand Limited 105 Pavilion Drive Mangere Auckland PO Box 53177 Auckland Airport Aucklan...

Страница 3: ...DD2 1P Measure return temp1 No Continue to advanced setup BMS relay Normally open Demand Duo dual pump Model DDSTAT DD2 2P Measure return temp1 No Alternate pump operation Yes Swap pumps every 12 hours Continue to advanced setup BMS relay Normally open Left power point INFINITY Right power point pump Left power point pump 1 Right power point pump 2 3 Service mode Hold 5 down then 1 3 1 1 All syste...

Страница 4: ...ange is 60 C to 82 C factory default is 65 C 2 Tank low limit temperature range is 3 C less than the tank set temperature down to 50 C factory default is 5 C Available configurations System description Model name LH GPO RH GPO Demand Rapid with one INF and one pump DD1 Permanently active for INF Pump DD 400 1000 with a single pump DD2 1P Disabled Pump DD 400 1000 with a two pumps DD2 2P Pump 1 Pum...

Страница 5: ...ratures follow the below steps TANK SET 65 ACCEPT TEMPERATURE 1 2 3 4 5 1 2 3 Press SET Press SET to allow the tank settings to be changed Change the tank set temperature Default is 65 C to change use buttons 4 and 5 and press ACCEPT button 2 TANK LOW LIMIT 60 ACCEPT TEMPERATURE 1 2 3 4 5 Change the low limit temperature Default is 60 C 5 C less than the tank set temperature To change use buttons ...

Страница 6: ... do this make sure the controller is switched on and the system display is showing CURRENT MODEL IS EXIT CHANGE DD2 1P V1 2 1 2 3 4 5 1 PUMP IT CM ID1 1 2 3 Access factory mode Hold down button 2 and press the following buttons in quick sequence Hold 2 5 4 5 5 If done correctly the next screen below will show the current model settings Change the factory setting To change the setting from what is ...

Страница 7: ...and Duo system for a single pump ensure you have selected the DDSTAT mode by following the instructions on the previous page 3 Bypass advanced setup The default settings for advanced setup are BMS connection open Controller ID 1 In the majority of installations just select No to bypass For more information refer to p 11 Controller ID refers to the controller number you can have up to 16 4 Access t...

Страница 8: ...ID 1 In the majority of installations just select No to bypass For more information refer to p 10 Controller ID refers to the controller number you can have up to 16 CONTINUE TO NO YES ADVANCED SETUP 1 2 3 4 5 To set the Demand Duo system for two pumps ensure you have selected the DDSTAT mode by following the instructions on p 6 Measure return temperature The default setting is NO Yes is only sele...

Страница 9: ...en press 5 4 5 5 in quick succession Demand Duo with a ring main The system in this configuration should have the Demand Duo controller set to the interrupt settings shown on the next page and the ring main pump controller often purchased as an additional accessory should be left in continuous mode If the Demand Duo controller has not been set do the below steps Bypass advanced setup The default s...

Страница 10: ...pt mode breaks the power supply to the pumps for a short period of time and allows for the Rinnai INFINITY commercial units to be stopped Select interrupt and press button 2 OK There are a series of options within this feature that allow you to select when the interrupt mode activates and the length of time the power remains off Select INTERRUPT AFTER and enter 28 minutes for DDSTAT and 10 minutes...

Страница 11: ...isplay will revert back to the default screen BMS CONNECTION ACCEPT RELAY NORMALLY 1 2 3 4 5 OPEN CONTROLLER ID ACCEPT 1 1 2 3 4 5 BMS connection on PCB F1 Fuse 20x5 1A ONLY PS1 L N 24V OV ZP0552400W BMS User Panel CN1 BMS Connection CN2 USER PANEL Connection CN3 RLY2 RLY3 OC2 OC1 ACTIVE NEUTRAL MAINS OC3 OC4 OC5 OC6 ACTIVE ACTIVE NEUTRAL NEUTRAL PUMP 1 PUMP 2 Serial label Barcode label Rinnai pow...

Страница 12: ...ogramming guide 12697 C Tel 0800 746 624 http www youtube com rinnainz http facebook com rinnainz Rinnai co nz Rinnai New Zealand Limited 105 Pavilion Drive Mangere Auckland 2022 PO Box 53177 Auckland Airport Auckland 2150 ...

Отзывы: