Electrical connection
The Compact 2 is fitted with a 1.5 m power
cord. The electrical connection can exit the
appliance from the lower left or right hand
side, or from the rear.
Direct wired installations
A qualified electrician will need to
be consulted where a direct wired
installation is required.
Installation must comply with the
requirements of AS/NZS 5601.1, AS/NZS 3000
and any other relevant local regulations.
Using existing externally mounted power
points on inbuilt installations
If there is an existing wall plug located outside
of the intended fireplace or enclosure you can
redirect the power cord and plug assembly
through the front panel. With the frame
assembly removed, redirect the cord and plug
assembly (with grommet) underneath the
heater to the front of the unit—either left or
right hand side.
Carefully remove the pre-punched metal
knock-out section on either the left or right
hand side of the frame assembly. Refit the
cord and plug assembly to the frame assembly
ensuring the grommet is fitted to the sheet
metal. Excess cord may be left in the cavity
BELOW the unit. DO NOT coil the excess cord.
IMPORTANT
Compact 2 power cord position - exiting rear of the
appliance
Compact 2 frame assembly - highlighting position of
metal knock-out tab
If a power point is used it must be 230 V, rated 10 A, and must be earthed. The
power point MUST NOT be located above the heater. Alternatively the appliance
can be direct wired if the power supply is to be concealed.