Rinnai CIN020MB Скачать руководство пользователя страница 1

Multi Split Type Air Conditioner

Installation Manual

REFRIGERANT

R32

Rinnai Inverter Multi Split System Models

Outdoor

Indoor Wall

Indoor Ducted

Indoor Cassette

MON3H07B

HINRP20M

DINSD26MB

CIN020MB

MON4H09B

HINRP26M

DINSD35MB

CIN026MB

MON5H11B

HINRP35M

DINSD50MB

CIN035MB

HINRP50M

DINSD70MB

CIN050MB

HINRP60M

HINRP70M

Содержание CIN020MB

Страница 1: ...GERANT R32 Rinnai Inverter Multi Split System Models Outdoor Indoor Wall Indoor Ducted Indoor Cassette MON3H07B HINRP20M DINSD26MB CIN020MB MON4H09B HINRP26M DINSD35MB CIN026MB MON5H11B HINRP35M DINSD50MB CIN035MB HINRP50M DINSD70MB CIN050MB HINRP60M HINRP70M ...

Страница 2: ...ith the manufacturer s instructions REFRIGERANT R32 The design and specifications are subject to change without prior notice for product improvement Consult with the Dealer or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version IMPORTANT Read this manual and SAFETY MANUAL carefully before installing or operating your new ai...

Страница 3: ...ns 15 REFRIGERANT PIPING CONNECTION 16 Outdoor Unit Dimensions 16 Connection Instructions Refrigerant Piping 17 WIRING 20 Outdoor Unit Wiring 21 Wiring Figure 22 Outdoor Wiring Diagram 3 Head models 23 Outdoor Wiring Diagram 4 Head models 24 Outdoor Wiring Diagram 5 Head models 25 AIR EVACUATION 27 Preparations and Precautions 27 Note on Adding Refrigerant 28 Safety and Leakage Check 29 TEST RUN 3...

Страница 4: ...ions to avoid electric shock fire or injury Do not insert fingers rods or other objects into the air inlet or outlet This may cause injury since the fan may be rotating at high speeds Do not use flammable sprays such as hair spray lacquer or paint near the unit This may cause fire or combustion Do not operate the air conditioner in places near or around combustible gases Emitted gas may collect ar...

Страница 5: ...ectrical work follow all local and national wiring standards regulations and the Installation Manual Connect cables tightly and clamp them securely to prevent external forces also cause shock All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units All wiring must be properly arranged to ensure that the control boa...

Страница 6: ...ter damage to your home and property Safety Precautions 2 Installation must be performed according to the installation instructions Improper installation 3 Contact an authorised service technician for repair or maintenance of this unit This appliance shall be installed in accordance with national wiring regulations Note about Fluorinated Gases 1 type of gas and the amount please refer to the relev...

Страница 7: ...on facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take back the old appliance free of charge Sell the appliance to certified scrap metal dealers Special notice Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment Hazardous substances may leak into the gro...

Страница 8: ...trol Operating Range Cooling C 16 32 Heating 0 30 Wi Fi Compatibility Standard MULTI OUTDOOR UNIT MON3H07B MON4H09B MON5H11B Number of Indoor Units Qty 3 4 5 Power Supply To Outdoor Unit V Ph Hz 220 240 1 50 Cooling Rated Capacity Range kW 7 5 1 7 9 8 9 15 1 7 11 5 12 0 1 7 12 3 Rated Input Power kW 1 98 2 38 3 42 Rated Input Current A 8 90 10 09 15 65 AEER W W 3 79 3 84 3 51 Heating Rated Capacit...

Страница 9: ...MB CIN35RMB CIN50RMB Fascia Panel Model No CINFASM Power Supply V Ph Hz 220 240 1 50 Cooling Rated Capacity kW 2 1 2 6 3 5 5 2 Rated Input Power W 40 40 40 102 Rated Input Current A 0 18 0 18 0 18 0 44 Heating Rated Capacity kW 2 3 2 9 4 1 5 4 Rated Input Power W 40 40 40 102 Rated Input Current A 0 18 0 18 0 18 0 44 Airflow Hi Med Lo L s 580 500 450 580 500 450 569 485 389 680 584 479 Sound Press...

Страница 10: ...ll rooms 60 197 80 262 80 262 Max length for one indoor unit 30 98 35 115 35 115 15 49 15 49 15 49 10 33 10 33 10 33 NOTE For the units adopt quick connectors no more than two pipes can be connected and the Max length for each pipe is 7 5 metres Specifications Specifications When installing multiple indoor units with a single outdoor unit ensure that the length of the refrigerant pipe and the drop...

Страница 11: ...dance on selecting a suitable remote controller The air conditioning system comes with the following accessories Use all of the installation parts and accessories to install the air conditioner Improper installation may result in water leakage electrical shock and fire or cause the equipment to fail The items are not included with the air conditioner must be purchased separately Varies by model Se...

Страница 12: ...NSTRUCTIONS Installation Summary Installation Summary INSTALLATION ORDER L N 1 2 3 MC MC 4 5 Install the outdoor unit Evacuate the refrigeration system Connect the wires Connect the refrigerant pipes Perform a test run Installation Summary L1 L2 ...

Страница 13: ... H Installation Safety Precautions plate Clip anchor CAUTION locate studs A minimum pipe run of 3 metres is required to minimise vibration excessive noise Two of the A B and C air circulation pathways must be free from obstructions at all times Refrigerant pipe Remote controller holder NOTE The installation must be performed in accordance with the requirement of local and national standards The in...

Страница 14: ... from extremely heavy winds See Figures below Strong wind Strong wind Strong wind If the unit is frequently exposed to heavy rain or snow Build a shelter above the unit to protect it from the rain or snow Be careful not to obstruct air flow around the unit If the unit is frequently exposed to salty air seaside Use outdoor unit that is specially designed to resist corrosion Wind Baffle Protected fr...

Страница 15: ... unit only Before bolting the outdoor unit in place you must install the drain joint at the bottom of the unit Note that there are two different types of drain joints depending on the type of outdoor unit If the drain joint comes with a rubber seal see Fig A do the following 1 Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit 2 Insert the drain joint into the ...

Страница 16: ...ole and helps seal it when you finish the installation process Size Outdoor Unit Dimensions mm Mounting Dimensions mm kW W x D x H Distance A Distance B 7 890 x 342 x 673 663 354 9 11 946 x 410 x 810 673 403 Rows of series installation The relations between H A and L are as follows L A L 1 2H 25 cm or more L H 1 2H L H 30 cm or more L H Can not be installed L H 300 cm or more 150 cm mo 60 cm A or ...

Страница 17: ...ter cut the pipe a little longer than the measured distance 3 Make sure that the pipe is cut at a perfect 90 angle DO NOT DEFORM PIPE WHILE CUTTING Be extra careful not to damage dent or deform the pipe while cutting This will drastically reduce the heating efficiency of the unit Step 3 Flare pipe ends Proper flaring is essential to achieve an airtight seal 1 After removing burrs from cut pipe sea...

Страница 18: ...Align the center of the two pipes that you will connect Indoor unit tubing Flare nut Pipe 3 Tighten the flare nut as tightly as possible by hand 4 Using a spanner grip the nut on the unit tubing 5 While firmly gripping the nut use a torque wrench to tighten the flare nut according to the torque values in above table NOTE Use both a spanner and a torque wrench when connecting or disconnecting pipes...

Страница 19: ... other wires While bundling these items together do not intertwine or cross the signal cable with any other wiring 7 Thread this pipeline through the wall and connect it to the outdoor unit 8 Insulate all the piping including the valves of the outdoor unit 9 Open the stop valves of the outdoor unit to start the flow of the refrigerant between the indoor and outdoor unit CAUTION Check to make sure ...

Страница 20: ...f 32 ohms 15 No other equipment should be connected to the same power circuit 16 Connect the outdoor wires before connecting the indoor wires 9 10 11 12 Every wire must be firmly connected Loose wiring can cause the terminal to overheat resulting in product malfunction and possible fire Do not let wires touch or rest against refrigerant tubing the compressor or any moving parts within the unit If ...

Страница 21: ...and 25 2 5 25 and 32 4 32 and 40 6 Using a wire crimper crimp u lugs on the ends b Using wire strippers strip the rubber jacket from both ends of the signal cable to reveal approximately 15cm of wire c Strip the insulation from the ends NOTE When connecting the wires strictly follow the wiring diagram found inside the electrical box cover CHOOSE THE RIGHT CABLE SIZE NOTE Choose the cable type acco...

Страница 22: ... the terminal block of the indoor and outdoor units For example Terminal L1 A of the outdoor unit must connect with terminal L1 1 on the indoor unit The outdoor unit can match different types of indoor unit the numbers on the terminal block of the indoor unit may be slightly different Please pay special attention while connecting the wire OPTIONAL 2 Cover Screw Remove the electric cover of the out...

Страница 23: ...Rinnai 23 Multi Split Type AC WIRING Outdoor Unit Wiring Diagram 3 Head models 3 Heads outdoor unit ...

Страница 24: ...Rinnai 24 Multi Split Type AC WIRING Outdoor Unit Wiring Diagram 4 Head models 4 Heads outdoor unit ...

Страница 25: ...Rinnai 25 Multi Split Type AC WIRING Outdoor Unit Wiring Diagram 5 Head models 5 Heads outdoor unit ...

Страница 26: ...ssing terminals all supply circuits must be disconnected Disconnection from a power supply must be incorporated into the fixed wiring It must have an air gap contact separation of at least 3mm in each active phase conductors Model K L P P U S R E W O P Y TO A TO B TO D TO E TO C NAL Wiring the circuit diagram posted on the inside of the control cover transporation Because loose screws may cause wi...

Страница 27: ...he system then close the valve after 5 seconds Flare nut Cap Valve body Valve stem 9 WatchthePressureGaugeforoneminutetomake surethatthereisnochangeinpressure Itshould readslightlyhigherthantheatmosphericpressure 10 Remove the charge hose from the service port 11 Using hexagonal wrench fully open both the high pressure and low pressure valves OPEN VALVE STEMS GENTLY When opening valve stems turn t...

Страница 28: ...efrigerant model make sure the conditions within the area have been made N 3 3 Head models N 4 4 Head models N 5 5 Head models Depending on the length of connective piping or the pressure of the evacuated system you made need to add refrigerant Refer to table below for refrigerant amounts to be added NOTE The standard pipe length is 10m Connective Pipe Length m Air Purging Method Additional Refrig...

Страница 29: ... only The actual order of A B C D and E on the machine may be slightly different from the unit you purchased but the general shape will remain the same Indoor unit check point Outdoor unit check point A B C D are points for the 4 Head model A B C D and E are points for the 5 Head model Page 40 solutions until the unit operates properly 1 Insulated resistance The insulated resistance must be more t...

Страница 30: ...em is unimpeded and draining smoothly g Ensure there is no vibration or abnormal noise during operation 5 For the Outdoor Unit a Check to see if the refrigeration system is leaking b Make sure there is no vibration or abnormal noise during operation c Ensure the wind noise and water generated by the unit do not disturb your neighbors or pose a safety hazard Test Run NOTE If the unit malfunctions o...

Страница 31: ...g error is corrected and all wiring piping is properly connected How To Activate This Function 1 Check that outside temperature is above 5 This function does not work when outside temperature is not above 5 2 Check that the stop valves of the liquid pipe and gas pipe are open 3 Turn on the breaker and wait at least 2 minutes 4 Press the check switch on the outdoor PCB board unit LED display C E Co...

Страница 32: ...are free For further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your appliance requires service please call our National Help Line Rinnai recommends that this appliance be serviced once a year With our policy of continuous impro...