Initiation
18/56
6.4
Switching the suction system on and off at the control cabinet
In manual mode, the suction system is switched on and off via the ON/OFF button. In automatic mode
this is accomplished via a machine contact.
If the suction system does not function after it has been switched on, or runs in the wrong direction, it
must be switched off, the plug must be removed from the socket and the technical specialist staff must
be alerted.
Pos : 9. 24 /6 I nbetri ebnahme/F alsc he Drehricht ung Seit enkanal verdic ht er @ 0 \ mod_1263537345108_131.doc x @ 1390 @ 2 @ 1
6.5
Incorrect rotational direction
If the rotational direction is incorrect, drives with side-channel compressor convey the suction air in the
inverse direction, i.e. an air current is discharged from the raw air suction nozzle of the suction system.
If this is the case, the suction system must be switched off immediately, the mains plug removed from
the mains socket and the technical personnel informed, so that the phase conductors in the mains
lead can be reversed.
Pos : 9. 25 /6 I nbetri ebnahme/ Vor dem Ei nsc hal ten prüfen @ 1\ mod_1336455105494_131. doc x @ 12450 @ 2 @ 1
6.6
Check the following before switching it on:
Pos : 9. 26 /6 I nbetri ebnahme/ Spänes auger/All e Filt er müss en ric htig eingesetzt s ei n. @ 1\ mod_1336459033816_131. doc x @ 12528 @ @ 1
•
All filters must be inserted correctly.
Pos : 9. 27 /6 I nbetri ebnahme/ Spänes auger/Die Entl eer kl appe muss korrekt versc hloss en s ein. @ 1\ mod_1336458953919_131.doc x @ 12520 @ @ 1
•
The emptying flap must be closed correctly.
Pos : 9. 28 /6 I nbetri ebnahme/ Spänes auger/D er Abs augsc hlauc h und das Z ubehör bz w. die R ohrleit ung müss en korrekt ver bunden s ei n. @ 1\ mod_1336459141674_131. doc x @ 12536 @ @ 1
•
The extraction hose and the accessories or pipe lines must be connected correctly.
Pos : 9. 29 /6 I nbetri ebnahme/ Bauar t 22/ Text z u Warns ymbol, Potenti alausgleic hslei tungen prüf en @ 0 \ mod_1262875164082_131.doc x @ 1100 @ @ 1
Before commissioning, always check that the potential equalization
conductors (earthing conductors) are connected!
Pos : 10.1 /7 Betri eb, Bedienung/ Betrieb, Bedienung, Kapi tel übersc hrift @ 0\ mod_1263539997200_131. doc x @ 1414 @ 1 @ 1