- 8 -
7 Assembly
7.1 Pay attention before the assembly
·
Danger of injuries!
·
Disconnect the drive before carrying out any work on the coupling!
·
Secure the drive against unintentional re-start and rotation!
·
Incorrectly tightened bolts can cause serious personal injuries and
property damages!
·
Assemble the coupling outside of the danger zone. Take care that
suitable transportation means are at disposal and that the transpor-
tation ways are free of obstacles.
·
In compliance with accident prevention regulations, you are
obliged to protect all freely rotating parts by means of permanently
installed guards/ covers against unintentional contact and falling
down objects.
·
To avoid sparks, the covers for couplings used should be made of
stainless steel!
·
As a minimum, the covers have to fulfil the requirements of protec-
tion type IP2X.
·
The covers have to be designed to prevent dust from depositing on
the coupling.
·
The cover must not contact the coupling or impair the proper
function of the coupling.
·
Make sure that the intended rotational speeds and torques as well as the ambient
tem-peratures do not exceed the values indicated in “6 Technical Data”.
·
The maximum permissible borehole diameter must not be exceeded.
·
Check whether the shaft hub connections can safely transmit the occurring operating
torques.
·
The standard RINGFEDER
®
TNM tolerance for the finished boreholes is fit H7.
·
Standard parallel key slot is according to DIN 6885 page 1.
·
Check the dimensions and tolerances of shafts, hub boreholes, parallel key and slot.
·
Adjust setscrews as required.
RINGFEDER
®
TNM GBT, TNM GTW
BAWN 006-
GBR