徐州睿德电器有限公司
XUZHOU RINGDER ELECTRICAL EQUIPMENT CO., LTD.
E-mail:
TEL: 86-516-66656756
; FAX: 86-516-87764448
Website: http://www.ringder.com; http://ringder.en.alibaba.com/
Huarun Industrial Park, Huarun Road, Tongshan District, Xuzhou City, Jiangsu Province, China. Zip code: 221142
OYTM-5S USER MANAUL
1.
DESCRIPTION
Totally micro-controlled, OYTM-5S monitors and indicates the temperature of 5 distinct points.
It is a tool of great versatility, which is excellent to measure the temperature in central, automotive or window air-conditioning, freezers,
check of overheating or over freezing in cold rooms, mean temperature inside environments, equipment in general and liquids.
It is also can be used at medical-hospital equipment.
Exclusive resources
Automatic or manual selection of 5sensors
Maximum and minimum temperature controls
HOLD Function (locking of instantaneous, maximum and minimum indications)
Offset in the indications
Low battery indicator
Indication of damaged sensor or temperature out of range
Indication of differential temperature
Indication of average temperature
Selection of temperature unit (°C or °F)
Auto power off (Programmable time)
2.
TECHNICAL SPECIFICATIONS
Power supply: two AAA battery
Temperature range: -50.0 to 105.0°C/-58.0 to 221 °F
Operating temperature : 0 to 50°C / 32 to 122°F
Resolution: 0.1 °C between 50.0 to 105.0°C/0.1°F between 58.0 to 199.9 °F/1°F between 200 to 221°F
Accuracy: ±0.3% f.s.
Number of sensors: 5
Sensors cable: diameter 2.8mm
Length: 1.5M
3.
DISPLAY INDICATIONS
Low battery, Minimum and maximum, Hold of display indication,
Average temperature, Differential temperature, Chosen
temperature unit, Chosen sensor
4.
USE INSTRUCTIONS
Press the key for 2 seconds to turn on the instrument.
The temperature measured in sensor NO.1 will be displayed and the respective indication will be blinking on the display.
To turn off the instrument hold pressing the key for 2 seconds.
4.1-Sensor selection
The selection of sensors is done pressing the key
To activate the automatic sensors selection just keep the key pressed for 3 seconds until the indication appears.
In the automatic selection mode the temperature of each sensor is shown for 3 seconds and the corresponding indication blinks faster (2
times per second).
To shut down the automatic selection, press the key again for 3 seconds until the indication is displayed.
The selection of the sensors occurs in the following order
:
---------------------------------------------
The symbols of each sensor used in the calculation of average temperature will be displayed
together with the average temperature value, as configured in the function.
The S1 and S2 symbols will be displayed together with the differential temperature value.
4.2-Hold function