2 | Product description
46 / 148
User and maintenance manual
2.9.1
BMS default thresholds
Designation
Value
Description
Final charging voltage
3.65 V The moment the first cell reaches this voltage, charging is temporar-
ily suspended.
Final discharge voltage
2.60 V The moment the first cell reaches this voltage, SOC is set to zero;
the vehicle stops.
Final battery charge
3.56 V As soon as all cells reach this voltage, charging is terminated.
Balanced start voltage
3.54 V As soon as one cell exceeds this limit, the electrical energy fed to
that cell during charging is converted into heat.
Minimum temperature
-10 °C As soon as the temperature at one temperature sensor reaches this
limit, error "Undertemperature" is triggered. Driving and charging is
no longer permitted.
Minimum temperature for
charging
0 °C
As soon as the temperature at one temperature sensor reaches this
limit, charging is no longer permitted.
Maximum temperature
60 °C
As soon as the temperature at one temperature sensor reaches this
limit, error "Overtemperature" is triggered. Driving and charging is
no longer permitted.