background image

5300N™ Operator 

 

2000516_A 

© 2007, Rimage Corporation 

Replace the Bin Present Sensor or the Bin Full Sensor on a Rimage 
5300N 

Use this procedure to replace the bin present sensor or the bin full sensor on a 

Rimage 5300N™

The procedures in this document should be performed only by personnel trained and authorized by Rimage. The instructions and 
content are written for mechanical and electrical service work assuming the technician has such training and authorization. The 
product warranty may become void if equipment or parts are tampered with, misused, neglected, or modified in any respect without 
the written consent of Rimage or by technicians who are not authorized or certified by Rimage. 

 

Before you begin  

1.  Stop or pause all jobs. 

2.  Power off the 

embedded control center

3.  Power off the 

5300N

4. Disconnect 

the 

power cord

#

 

Required tools

:

 

 

¼” nut driver 

 

Torx T8 screwdriver 

 

Torx T10 screwdriver 

 

 

Access the sensors 

1. Open 

the 

front door

2. Remove 

the 

nuts

 (Qty. 2) securing the sensor bracket. 

3. Remove 

the 

sensor bracket 

and 

sensors

 

4. Disconnect 

the 

sensor cables

 (Qty. 2) from the sensors. 

n

 

Caution! Some cables in this system are latched. 
Equipment damage may occur if cables are not 
disconnected appropriately. 

 

 

Sensor Bracket 

and Sensors 

Sensor Cables 

Отзывы: