background image

RP-2009 Pump for the GX-2009

 

 

Product Warranty

 

RIKEN

 

KEIKI.

 

warranties

 

gas

 

alarm

 

equipment

 

sold

 

by

 

us

 

to

 

be

 

free

 

from

 

defects

 

in

 

materials,

 

workmanship,

 

and

 

performance

 

for

 

a

 

period

 

of

 

one

 

year

 

from

 

date

 

of

 

shipment

 

from

 

RIKEN

 

KEIKI.

 

Any

 

parts

 

found

 

defective

 

within

 

that

 

period

 

will

 

be

 

repaired

 

or

 

replaced,

 

at

 

our

 

option,

 

free

 

of

 

charge.

 

This

 

warranty

 

does

 

not

 

apply

 

to

 

those

 

items

 

which

 

by

 

their

 

nature

 

are

 

subject

 

to

 

deterioration

 

or

 

consumption

 

in

 

normal

 

service,

 

and

 

which

 

must

 

be

 

cleaned,

 

repaired,

 

or

 

replaced

 

on

 

a

 

routine

 

basis.

 

Examples

 

of

 

such

 

items

 

are:

 

 

a) Absorbent cartridges 

d) Batteries 

b) Pump diaphragms and valves 

e) Filter elements 

c) Fuses 

 

Warranty

 

is

 

voided

 

by

 

abuse

 

including

 

mechanical

 

damage,

 

alteration,

 

rough

 

handling,

 

or

 

repair

 

procedures

 

not

 

in

 

accordance

 

with

 

the

 

operator’s

 

manual.

 

This

 

warranty

 

indicates

 

the

 

full

 

extent

 

of

 

our

 

liability,

 

and

 

we

 

are

 

not

 

responsible

 

for

 

removal

 

or

 

replacement

 

costs,

 

local

 

repair

 

costs,

 

transportation

 

costs,

 

or

 

contingent

 

expenses

 

incurred

 

without

 

our

 

prior

 

approval.

 

THIS

 

WARRANTY

 

IS

 

EXPRESSLY

 

IN

 

LIEU

 

OF

 

ANY

 

AND

 

ALL

 

OTHER

 

WARRANTIES

 

AND

 

REPRESENTATIONS,

 

EXPRESSED

 

OR

 

IMPLIED,

 

AND

 

ALL

 

OTHER

 

OBLIGATIONS

 

OR

 

LIABILITIES

 

ON

 

THE

 

PART

 

OF

 

RIKEN

 

KEIKI.,

 

INCLUDING

 

BUT

 

NOT

 

LIMITED

 

TO,

 

THE

 

WARRANTY

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE.

 

IN

 

NO

 

EVENT

 

SHALL

 

RIKEN

 

KEIKI.

 

BE

 

LIABLE

 

FOR

 

INDIRECT,

 

INCIDENTAL,

 

OR

 

CONSEQUENTIAL

 

LOSS

 

OR

 

DAMAGE

 

OF

 

ANY

 

KIND

 

CONNECTED

 

WITH

 

THE

 

USE

 

OF

 

ITS

 

PRODUCTS

 

OR

 

FAILURE

 

OF

 

ITS

 

PRODUCTS

 

TO

 

FUNCTION

 

OR

 

OPERATE

 

PROPERLY.

 

This

 

warranty

 

covers

 

instruments

 

and

 

parts

 

sold

 

to

 

users

 

by

 

authorized

 

distributors,

 

dealers,

 

and

 

representatives

 

as

 

appointed

 

by

 

RIKEN

 

KEIKI.

 

We

 

do

 

not

 

assume

 

indemnification

 

for

 

any

 

accident

 

or

 

damage

 

caused

 

by

 

the

 

operation

 

of

 

this

 

gas

 

monitor,

 

and

 

our

 

warranty

 

is

 

limited

 

to

 

the

 

replacement

 

of

 

parts

 

or

 

our

 

complete

 

goods.

 

Содержание PT9E-0137

Страница 1: ...PT9E 0137 RP 2009 Pump for the GX 2009 Operating Manual...

Страница 2: ...to 50 C Electrical data Powered by an AA size alkaline battery model LR6 by TOSHIBA Certificate numbers IECEx Certificate number IECEx DEK 12 0066 ATEX Certificate number DEKRA 12ATEX0209 List of stan...

Страница 3: ...y indicates the full extent of our liability and we are not responsible for removal or replacement costs local repair costs transportation costs or contingent expenses incurred without our prior appro...

Страница 4: ...t Filter 12 Replacing the Hydrophobic Disk Filter and Wire Mesh Disk 13 Parts List 14 WARNING Understand manual before operating and for proper battery type Substitution of components may impair intri...

Страница 5: ...specifications for the RP 2009 pump Table 1 Specifications Power Supply 1 ea AA size alkaline Operating Time 8 hours minimum at 25 C Operating Temperature Humidity 20 C to 50 C 0 85 Relative Humidity...

Страница 6: ...mple nipple Sensor Adapter Power LED Top Instrument Release Indicator Low Flow LED Power Button Filter Holder Rubber Sample Nipple OPEN RELEASE POWER LOW FLOW RESET LOCK RP 2009 POW ER Instrument Lock...

Страница 7: ...unit The exhaust fitting is located under the battery cap tab A POWER button a power indication LED and a low flow LED are located along the middle front of the pump unit The power LED is on when the...

Страница 8: ...r some other access to an enclosed area to sample the environment Optional Hose Probe When desired the rubber sample nipple may be removed and a sample hose and probe with GX 7 fittings optional acces...

Страница 9: ...nstall the GX 2009 onto the RP 2009 without rotating the battery cap to RELEASE Installing the GX 2009 onto the RP 2009 with the battery cap in the LOCK position may result in damage to the RP 2009 3...

Страница 10: ...h the GX 2009 Be sure that the RP 2009 is fully engaged on the instrument When fully engaged the GX 2009 should not move around at all CAUTION If the RP 2009 is not fully engaged the unit will not res...

Страница 11: ...5 Secure the GX 2009 in the RP 2009 by pushing down on the battery cap and rotating it an 1 8 turn clockwise so that the indicator tab on the battery cap is next to LOCK Indicator Tab PUSH LOCK Figur...

Страница 12: ...turns green about 2 seconds WARNING While the GX 2009 is installed in the RP 2009 the pump must be on for the GX 2009 to function as a gas detection monitor 9 Go to the area to be sampled If the rubbe...

Страница 13: ...2009 pump does have a hydrophobic filter built in the optional probe does not have a hydrophobic filter It has a dust filter only 10 Monitor the GX 2009 display for the gas readings and take appropria...

Страница 14: ...ckwise so that the indicator tab on the battery cap is next to RELEASE Indicator Tab RELEASE Figure 6 Releasing the Battery Cap WARNING Do not remove the GX 2009 from the RP 2009 without rotating the...

Страница 15: ...OWER Figure 7 GX 2009 Removal Low Flow Alarm When pump unit experiences a low flow condition the low flow LED starts flashing and the pump stops operating Check the rubber sample nipple and filters to...

Страница 16: ...cap over the battery onto the pump unit push it down and turn it clockwise unit is stops beneath the instrument release tab Replacing the Cotton Dust Filter 1 Locate the clear plastic filter holder at...

Страница 17: ...located in the pump unit and are retained by a rubber gasket Pull out the rubber gasket with needle nose pliers Hydrophobic Disk Filter Cotton Dust Filter Rubber Gasket Filter Holder Wire Mesh Disk In...

Страница 18: ...kwise until it snaps into place Parts List Table 2 lists replacement parts and accessories for the RP 2009 pump Table 2 Parts List Part Number Description 4181 5430 10 Gasket filter screen retaining 1...

Страница 19: ......

Отзывы: