Rigol PR7080S Скачать руководство пользователя страница 40

RIGOL 

10 

RP7000S User’s Guide 

To Connect to the Oscilloscope 

 
After RP7000S is connected correctly to a 

RIGOL

 DS6000 or DS4000 series 

oscilloscope, the oscilloscope recognizes the probe automatically and provides 
both power and offset voltage to the probe. You can adjust the offset voltage 
(refer to To Adjust Offset Voltage) and calibrate the probe (refer to To 
Calibrate the Probe
)
 by the front panel menu of the oscilloscope. 
 
Please connect the probe to the oscilloscope following the steps below: 
 

1.

 

Connect the probe head (in the figure, taking a hand-held differential 
probe head for example) with the active probe amplifier. If single-ended 
probe head is used, during the connection, pay attention to their polarities.   

 

2.

 

Connect the other end of the active probe amplifier to the channel input or 
external trigger input connector of the oscilloscope and make sure the 
connection is tight.   

 

Содержание PR7080S

Страница 1: ...R RI IG GO OL L RP7000S 2013 11 RIGOL Technologies Inc...

Страница 2: ......

Страница 3: ...RIGOL RP7000S I 2013 RIGOL UGE21001 1110 RIGOL RIGOL RIGOL ISO9001 2008 ISO14001 2004 RIGOL service rigol com www rigol com...

Страница 4: ...RIGOL RP7000S II...

Страница 5: ...RIGOL RP7000S III RP7000S RP7000S PR7150S 1 5GHz RP7080S 800MHz RP7000S RP7000S...

Страница 6: ...RIGOL RP7000S IV I II III RP7000S 1 2 2 3 4 6 7 RP7000S 9 10 12 13 13 14 15 16 17...

Страница 7: ...RIGOL RP7000S 1 RP7000S RP7000S...

Страница 8: ...RIGOL RP7000S 2 RP7000S RP7000S RP7000S RIGOL DS6000 DS4000 BNC RP7000S 1 RIGOL 2 RIGOL 3 RIGOL...

Страница 9: ...RIGOL RP7000S 3 1 RP7000S 1...

Страница 10: ...000S RIGOL RP7150S RP7150S 1 1 RP7080S RP7080S 2 2 1 RP7150S RP7150S PCK100 PCK100 1 RP7150S RP7S 0150 1 RP7S 0205 1 91 RP7 0405 9 RP7 0501 2 RP7 0502 2 RP7 0503 2 RP7 0504 2 RP 0203 8 RP7S 0601 1 RP7...

Страница 11: ...RIGOL RP7000S 5 2 RP7080S RP7080S PCK100 PCK100 1 RP7080S RP7S 0080 1 RP7S 0205 1 91 RP7 0405 9 RP7 0501 2 RP7 0502 2 RP7 0503 2 RP7 0504 2 RP 0203 8 RP7S 0601 1 RP7 0602 1 RP7 0603 1...

Страница 12: ...RIGOL RP7000S 6 2 1 5GHz DS6000 DS4000 2...

Страница 13: ...RIGOL RP7000S 7 RP7000S 3 3 4 5 RP7000S 5 a b c d 4...

Страница 14: ...RIGOL RP7000S 8 a 5...

Страница 15: ...RIGOL RP7000S 9 RP7000S RP7000S RP7000S...

Страница 16: ...RIGOL RP7000S 10 RP7000S RIGOL DS6000 DS4000 1 2...

Страница 17: ...RIGOL RP7000S 11 3 4 BNC...

Страница 18: ...RIGOL RP7000S 12 1 5GHz 6 6 RP7S 0205 91 RP7 0405 0mm 5mm RP7 0501...

Страница 19: ...RIGOL RP7000S 13 1 2 3 RIGOL DS6000 DS4000 RP7000S 1 RP7000S DS6000 DS4000 CH1 2 DS6000 DS4000 CH1...

Страница 20: ...RIGOL RP7000S 14 RP7000S PCK100 RP7000S 1 1 BNC SMA BNC BNC SMA 1 2 RP7000S CH1 CH4 CH1 3 CH1 1 BNC BNC Trig Out Calibration 4 5 40 50 RP7000S CH1...

Страница 21: ...RIGOL RP7000S 15 1 2...

Страница 22: ...RIGOL RP7000S 16 RIGOL RIGOL RIGOL RIGOL RIGOL RIGOL...

Страница 23: ...RIGOL RP7000S 17 RP7150S RP7080S 1 5GHz 800MHz 265ps 465ps 1GHz DS6104 DS6102 800MHz DS6104 DS6102 1pF 100k 2 6 25V 10 1 2 1 30mV 5mV 12V 1 3 1 70mVpp 7ns 30V Peak CAT I 2 8kV...

Страница 24: ...RIGOL RP7000S 18 5 C 40 C 40 C 70 C 0 RH 80 RH 0 RH 90 RH 4600m 15300m 1 2W N A 132 10g 3 1305 50g 4 1 4m 1 2 CAT I CAT II I II II III 3 RP7000S 4 RP7000S...

Страница 25: ...R RI IG GO OL L User s Guide RP7000S Series Single Ended Active Probe Nov 2013 RIGOL Technologies Inc...

Страница 26: ......

Страница 27: ...not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any part of this documen...

Страница 28: ...r practices that could result in damage to this product or loss of data Terms on the Product The following terms may appear on the product DANGER indicates a hazard may immediately happen WARNING indi...

Страница 29: ...the following model Model Bandwidth PR7150S 1 5GHz PR7080S 800MHz Main topics in this manual RP7000S Series Overview This chapter gives a brief introduction of the probe including general inspection...

Страница 30: ...ion 2 General Inspection 2 Probe Dimensions 3 Accessories and Options 4 Active Probe Amplifier 6 Probe Head 7 To Use RP7000S Series 9 To Connect to the Oscilloscope 10 To Use Hand held Single ended Pr...

Страница 31: ...ries Overview This chapter guides users to quickly get familiar with the RP7000S series single ended active probe Main topics Probe Introduction General Inspection Probe Dimensions Accessories and Opt...

Страница 32: ...ction with the oscilloscope RP7000S provides various accessories and options and multiple replaceable components which make it applicable to be used in different tests and measurements General Inspect...

Страница 33: ...s according to Accessories and Options in this guide If the accessories are incomplete or damaged please contact your RIGOL sales representative Probe Dimensions Figure 1 shows the dimensions of the m...

Страница 34: ...he accessories listed inTable 2 If any accessory or option needs to be ordered separately please refer to Table 2 Table 1 Standard Accessories of RP7150S Single Ended Active Probe Kit Ordering No is R...

Страница 35: ...eld Single ended Probe Head RP7S 0205 1 91 Probe Tip RP7 0405 9 Straight Acuminate Ground Collar RP7 0501 2 Curved Acuminate Ground Collar RP7 0502 2 Straight Dentiform Ground Collar RP7 0503 2 Curved...

Страница 36: ...desired probe head Figure 2 Active Probe Amplifier When connecting a probe head to an active probe amplifier push it straight in For single ended probe when connecting them pay attention to their pol...

Страница 37: ...ith a new one refer to To Replace Probe Accessories RP7000S provides 4 kinds of single ended ground collars for different measurement requirements the structures of the ground collars are as shown in...

Страница 38: ...OL 8 RP7000S User s Guide Figure 4 Probe Tip a Straight Acuminate Ground Collar b Curved Acuminate Ground Collar c Straight Dentiform Ground Collar d Curved Dentiform Ground Collar Figure 5 Ground Col...

Страница 39: ...prolong the service life of the probe and ensure the effectiveness of the signal measurement result This chapter introduces in detail the using method of the RP7000S series single ended active probe...

Страница 40: ...probe refer to To Calibrate the Probe by the front panel menu of the oscilloscope Please connect the probe to the oscilloscope following the steps below 1 Connect the probe head in the figure taking...

Страница 41: ...nect the probe from the oscilloscope press the button on the probe as shown in the left figure below pull the connector straight out of the oscilloscope as shown in the right figure below and then rel...

Страница 42: ...ing between the single ended ground collar and probe tip can be adjusted by rotating the ground collar and the replaceable probe tip and single ended ground collar prolong the service life of the prob...

Страница 43: ...ecting the probe performance when replacing the probe head Replacing Method Disconnect the current probe head from the active probe amplifier Push the new probe head into the active probe amplifier st...

Страница 44: ...H1 of the DS6000 DS4000 oscilloscope referring to To Connect to the Oscilloscope 2 Open the probe offset voltage control menu of the DS6000 DS4000 oscilloscope front panel operation CH1 Probe Bias Vol...

Страница 45: ...middle signal line Note it is recommended to place the probe tip at the middle of the calibration board 5 Press Start and the oscilloscope starts to calibrate the probe The calibration will last for a...

Страница 46: ...om any corrosive liquid Cleaning Clean the probe and its accessories regularly according to their operation conditions using the method below 1 Disconnect the probe from the oscilloscope or voltage so...

Страница 47: ...ription please refer to RIGOL official website or the warranty card To get repair service or a complete copy of the warranty description please contact with your nearest RIGOL sales and service office...

Страница 48: ...r DS6102 Input Capacitance 1pF Input Resistance 100k 2 Input Dynamic Range 6 25V DC Attenuation 10 1 2 Zero Offset Error 1 30mV before calibration 5mV after calibration Offset Voltage Range 12V Offset...

Страница 49: ...AT II Definitions Installation Category Overvoltage Category I signal level special equipment or parts of equipment telecommunication electronic etc with smaller transient voltages than installation c...

Отзывы: