RIGOL
2-104
User’s Guide for DSA1000 Series
2.6.3
Preset
Restores the analyzer to a specified status. This may change all parameters related to
the sweep, the measurement function and the system.
Key Points:
Press System
Reset
Preset Type to select Factory or User.
Press Preset to load Factory settings (except for items marked with “**”) listed
in the following table or User-defined settings.
Table 2-65 Factory Default
Parameter
Default
Frequency
Center Freq
1.5 GHz
Start Freq
0 Hz
Stop Freq
3 GHz
CF Step
Auto, 300 MHz
Signal Track
Off
Span
Span
3 GHz
Amplitude
Ref Level
0 dBm
Ref Offset
0 dB
Scale/Div
10 dB
Input Atten
Auto, 10 dB
Scale Type
Log
Units
dBm
RF Preamp***
Off
MaxMixL
-10 dBm
Corr
Corrections
Off
Detector
Detector Type
Pos Peak
Demod
Demod
Off
Speaker
Off
Содержание DSA1030
Страница 1: ...RIGOL User s Guide DSA1000 Series Spectrum Analyzer Sept 2014 RIGOL Technologies Inc...
Страница 2: ......
Страница 22: ......
Страница 179: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 3 Figure 3 1 Measuring a Sine signal...
Страница 181: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 5 Figure 3 2 Use the frequency counter to measure...
Страница 186: ...RIGOL Measurement Examples 3 10 User s Guide for DSA1000 Series Figure 3 4 Phase noise measurement...
Страница 188: ...RIGOL Measurement Examples 3 12 User s Guide for DSA1000 Series Figure 3 5 N dB bandwidth measurement result...
Страница 190: ...RIGOL Measurement Examples 3 14 User s Guide for DSA1000 Series Figure 3 6 Time domain power measurement...
Страница 192: ...RIGOL Measurement Examples 3 16 User s Guide for DSA1000 Series Figure 3 7 Adjacent channel power measurement result...
Страница 194: ...RIGOL Measurement Examples 3 18 User s Guide for DSA1000 Series Figure 3 8 Channel power measurement result...
Страница 196: ...RIGOL Measurement Examples 3 20 User s Guide for DSA1000 Series Figure 3 9 Occupied bandwidth measurement result...
Страница 198: ...RIGOL Measurement Examples 3 22 User s Guide for DSA1000 Series Figure 3 10 Emission bandwidth measurement result...
Страница 200: ...RIGOL Measurement Examples 3 24 User s Guide for DSA1000 Series Figure 3 11 C N Ratio measurement result...
Страница 204: ...RIGOL Measurement Examples 3 28 User s Guide for DSA1000 Series Figure 3 13 Harmonic Distortion measurement result...
Страница 211: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 35 Figure 3 17 Amplitude correction...
Страница 213: ...Measurement Examples RIGOL User s Guide for DSA1000 Series 3 37 Figure 3 18 The frequency response of a filter...
Страница 214: ......