RIGOL
DS4000E Programming Guide
2-215
:TRIGger:RUNT:WUPPer
Syntax
:TRIGger:RUNT:WUPPer <width>
:TRIGger:RUNT:WUPPer?
Description
Sets or queries the maximum pulse width (i.g. upper limit of the pulse width) of Runt trigger when the
trigger condition is "LESS" or "GLESs" (refer to the :TRIGger:RUNT:WHEN command).
Parameter
Name
Type
Range
Default
<width>
Discrete
The range of <width> is from 4 ns to 4 s when the trigger
condition is "LESS".
The range of <width> is from 12 ns to 4 s when the
trigger condition is "GLESs".
2 us
Remarks
If the trigger condition is "GLESs" (refer to the :TRIGger:RUNT:WHEN command), the maximum pulse
width must be greater than the current minimum pulse width (refer to the :TRIGger:RUNT:WLOWer
command).
Return Format
The query returns the maximum pulse width in scientific notation.