Quick Guide 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

DS1000Z-E Series Digital 

Oscilloscope 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

Aug. 2019 

RIGOL

 (SUZHOU) TECHNOLOGIES INC.

Содержание DS1000Z-E Series

Страница 1: ...Quick Guide DS1000Z E Series Digital Oscilloscope Aug 2019 RIGOL SUZHOU TECHNOLOGIES INC...

Страница 2: ......

Страница 3: ...lication is subject to change without notice RIGOL shall not be liable for either incidental or consequential losses in connection with the furnishing use or performance of this manual as well as any...

Страница 4: ...electrostatic impact 16 Handle with caution Safety Notices and Symbols Safety Notices in this Manual WARNING Indicates a potentially hazardous situation or practice which if not avoided will result in...

Страница 5: ...easurements performed in the building installation Examples are measurements on distribution boards circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixe...

Страница 6: ...rbolt can reach the product or else the operator might expose to danger of electric shock Installation Overvoltage Category Definitions Installation overvoltage category I refers to signal level which...

Страница 7: ...ounded Product Care and Cleaning Care Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time Cleaning Clean the instrument regularly according to its...

Страница 8: ...ion Document Overview This manual is used to guide users to quickly get familiar with the front panel rear panel user interface and basic operation method of DS1000Z E series digital oscilloscope You...

Страница 9: ...ITION Vertical Position Knob TRIGGER LEVEL Trigger Level Knob Content Conventions in this Manual DS1000Z E series includes the following models Unless otherwise noted this manual takes DS1202Z E as an...

Страница 10: ...pearance and Dimensions 2 To Prepare for Operation 3 To Adjust the Supporting Legs 3 To Connect to AC Power Supply 3 Turn on Checkout 4 To Connect the Probe 4 Function Inspection 5 Probe Compensation...

Страница 11: ...shall be liable for the damage to the instrument resulting from shipment RIGOL would not be responsible for free maintenance rework or replacement of the instrument 2 Inspect the instrument In case of...

Страница 12: ...RIGOL 2 DS1000Z E Quick Guide Appearance and Dimensions Figure 1 Front View Unit mm Figure 2 Top View Unit mm...

Страница 13: ...nt of the oscilloscope as well as better operation and observation Figure 3 To Adjust the Supporting Legs To Connect to AC Power Supply This oscilloscope can accept 100 240 V 45 440 Hz AC power supply...

Страница 14: ...ion and remaining trial time of the option currently installed To Connect the Probe RIGOL provides passive probe for DS1000Z E series For the model of the probes please refer to DS1000Z E Series Datas...

Страница 15: ...mal condition the display should be a square waveform as shown in the figure below Figure 7 Square Waveform 6 Use the same method to test the other channels If the square waveforms actually shown do n...

Страница 16: ...probe compensation procedures are as follows 1 Perform Step 1 2 3 and 4 specified in Function Inspection 2 Check the displayed waveforms and compare them with the waveforms in the following figure Fig...

Страница 17: ...t 2 LCD 11 Power Key 3 Function Menu Softkeys 12 USB Host Interface 4 Multifunction Knob 13 Analog Channel Input 5 Common Operation Keys 14 VERTICAL Control Area 6 CLEAR 15 HORIZONTAL Control Area 7 A...

Страница 18: ...n connect the oscilloscope to a PictBridge printer or PC via this interface When a PC is connected users can send SCPI commands using the PC software or control the oscilloscope via user defined progr...

Страница 19: ...please use the specified fuse 250V T2A The operation method is as follows a Turn off the instrument disconnect the power and then remove the power cord b Insert a small straight screwdriver into the s...

Страница 20: ...turn counterclockwise to decrease During the modification the waveform would move up and down and the position message e g at the lower left corner of the screen would change accordingly Press down t...

Страница 21: ...rms of all the channels will be displayed in expanded or compressed mode and the time base message e g at the upper side of the screen would change accordingly Press down this knob to quickly switch t...

Страница 22: ...uto setting function requires that the frequency of sine is no lower than 41 Hz the duty cycle should be greater than 1 and the amplitude must be at least 20 mVpp for square Otherwise the Waveform aut...

Страница 23: ...is key to open the measurement setting menu You can set the measurement source turn on or off the frequency counter all measure statistic function and etc Press MENU at the left of the screen to switc...

Страница 24: ...s the pass fail test waveform record etc are also supported Print Press this key to print the screen or save the screen to a USB storage device If a PictBridge printer is connected currently and the p...

Страница 25: ...MENU continuously to switch between the horizontal and vertical parameters 2 Status Available states include RUN STOP T D triggered WAIT and AUTO 3 Horizontal Time Base Represent the time per grid on...

Страница 26: ...s are displayed when different trigger sources are selected and the color of the trigger parameter area will change accordingly For example denotes that CH1 is selected as the trigger source 10 Trigge...

Страница 27: ...s detected will be displayed 16 Operation Menu Press any softkey to activate the corresponding menu The following symbols might be displayed in the menu Denote that you can rotate the multifunction kn...

Страница 28: ...er all the value input rotate the knob to select the desired unit press down the knob to finish your input Figure 12 Numeric Keyboard To Use the Security Lock If needed you can use the security lock p...

Страница 29: ...the help interface and press again to close the interface The help interface mainly consists of two parts The left is Help Options and the right is Help Display Area Figure 14 Help Information You ca...

Страница 30: ...locate the problem 3 Resample the signal 3 The voltage amplitude measured is greater or smaller than the actual value note that this failure usually only occurs when probe is used Check whether the p...

Страница 31: ...Check whether the USB cable is correctly connected to the instrument and PC 3 Check whether the USB cable is in good condition If needed restart the oscilloscope 8 The USB storage device cannot be re...