:ANALyzer:CURRent:THRE?
<
ch>,<type>
Description
Sets or queries the limit value of positive/negative pulse for the pulse current analysis
function.
Parameter
Name
Type
Range
Default
<ch>
Discrete
{CH1|CH2}
-
<type>
Discrete
{UP|LOW}
-
<bool>
Bool
{0|1|ON|OFF}
OFF
<val>
Real
0 to 3.15 A
Positive: 1 A
Negative: 0.1 A
Remarks
•
UP sets <val> for positive pulse. In the analysis process, the analyzer records the
number of pulses above the threshold and the most recent pulse width beyond
this upper threshold.
•
LOW sets <val> for negative pulse. In the analysis process, the analyzer records
the number of pulses below the threshold and the most recent pulse width
below this threshold.
Return Format
The query returns the on/off state of the upper or lower limit and the specific limit
value for the selected channel. For example, the query may return 1,1.000.
Examples
:ANALyzer:CURRent:THRE CH1,UP,ON,1 /*Sets the positive pulse
threshold to 1 A for CH1 pulse current analysis.*/
:ANALyzer:CURRent:THRE? CH1,UP /*Queries the positive pulse
threshold for CH1 pulse current analysis. The query returns
1,1.000.*/
4.1.4
:ANALyzer:SAVE:ROUTe
Syntax
:ANALyzer:SAVE:ROUTe
<
dest>
:ANALyzer:SAVE:ROUTe?
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
15
Содержание DP900 Series
Страница 1: ......
Страница 133: ...d Exit Programming Examples Copyright RIGOL TECHNOLOGIES CO LTD All rights reserved 125 ...
Страница 141: ......