Operating Manual
Breite: 170
Höhe:8,15
Oben Links
278,5 20
RIFOX - Hans Richter GmbH Spezialarmaturen Fon: +49 (0) 421 499 75 - 0 Internet: www.rifox.de
Bertha-von-Suttner-Str. 9 D-28207 Bremen Fax: +49 (0) 421 499 75 - 40 Email: [email protected]
Page 1 of 5
10/2020
-Di.
Subject to modifi
ca
tions
Model: 1101-N
Model: 1180-N
Float-Controlled Condensate Trap, PN 25
1
Safety instructions
1.1
Proper use
Any improper use, intervention in the design and deviation from the design data automatically lead to termination of the
warranty. The fl oat-controlled condensate trap is designed for the discharge of condensate from steam, compressed air and
pressure gas systems. Any other usage is not permitted. The manufacturer is not liable for damage resulting from any other
usage. The user or operator bears the risk in this case. This also applies analogously to incorrect assembly, start-up, use and
maintenance.
1.2
Warnings and symbols
■
Personal risk due to escaping operating medium because of pressure, temperature and weight. Failure to comply with
these warnings results in the risk of accidents.
■
Follow the instructions in this operating manual.
■
The operator must ensure that this operating manual and, if necessary, other relevant documents are available on site.
■
Only trained or instructed personnel may be assigned to handling this equipment.
■
Any mode of operation that may impair safety must be avoided.
2
General description and usage
2.1
Design of the condensate trap
13
4
5
2
7
9
8
12
6
3
10
1
14
11
14
7
9
5
1
3
2
13
6
10
12
8
Picture 1: Model 1101-N
Picture 2: Model 1180-N
01
Upper part of housing
08
Supporting body assembly
02
Housing gasket
09
Float
03
Lower part of housing
10
Supporting screw
04
Control valve
11
Control Screw
05
Set screw with nuts
12
Gasket
06
Screw plug
13
Gasket
07
Float control assembly
14
Gasket