1 Introduction

Glass break detector «Zvon-1» ver. 1 (hereinafter, the Detector) is 

designed to provide the following tasks performance:

- detecting destruction of construction glass: common and laminated 

with polymer film, installed in structural units (openings) and/or interior 
elements of closed spaces;

- generates alarm messages by «ALARM» contacts opening;
- generates tamper message by «TAMP» contacts opening;
- possibility of wall or ceiling installation, as well as installation at 

partition between secured glass and a curtain.

2 Specifications

Table 1

Parameter

Value

Maximal detection range, not less than:

- at minimum monitored glass area 0,1 m

2

- at minimum monitored glass area 1 m

2

6 m

10 m

Power supply

9 … 17 V DC

Warm up time

3 sec

Alarm message duration, not less than

2 sec

Operating temperature

minus 20 … +45 

о

С

Permissible relative humidity at temperature 20 

о

C

90 %

IP rating

IP30

Consumption current, not more than

23 mА

Dimensions, not more than

80 х 47 х 29 mm

Mass, not more than

0.06 kg

Average service life, not less

8 years

* – Area of visible (opened) surface of a glass (glass unit), installed into a 

window frame

3 Informational Content

Table 2

Status

LED Indicator

Contects

Red

Yellow

Green

AL

TAMPER

«Norm»

OFF

OFF

OFF

Closed

Closed

«Alarm»

ON

*

*

Opened

*

«Switching ON»

«Low Power 

Supply»

«Interference on the  

1-st Frequency»

*

ON

*

*

*

«Interference on the  

2-nd Frequency»

*

*

ON

*

*

«Adjustment»

*

*

ON (at 1 Hz 

frequency)

*

*

«Tamper»

*

*

*

*

Opened

* – without changes

4 Detection Zone Pattern

GLASS BREAK 

DETECTOR

«ZVON-1» ver. 1

Installation Guide

Figure 2 – The Detector without Cover 

PCB  comprises  marked  terminals  (11)  for  connection  with  control 

panel, anti tamper switch (4), three LED indicators (8), microphone (10) 
and jumpers (7) for the Detector adjustment.

6.2 For the Detector installation act as follows:
- insert a flat screwdriver into the slot at the side wall of the cover, 

push the latch (5) and put off the cover;

- fasten the base with the PCB by the screw to the mounting surface 

at the chosen place of installation;

- open the necessary quantity oh holes (12) in the sidewall of the 

base, insert and pull wires through them;

- connect the Detector to the control panel in accordance with it’s 

manual.

7 Switching ON and Adjustment

Install jumpers MODE and IND, remove SENS jumper.
Energize the Detector. At this moment red LED indicator should light 

up for 3 sec and get out, what is indicating the Detector turnover to 
standby mode. If indication displays interferences presence, eliminate 
it cause if possible.

Fulfill the Detector adjustment as follows:
- remove the MODE jumper (mode «Adjustment»);

-  suspend  a  steel  ball  21  –  22  mm  in  diameter  on  a  35  cm  long 

thread near the farthest part of the monitored glass, deflect it at an 

angle of 30 – 70° (see Table 4). Deliver a blow to the most distant place 

of the secured glass. If red indicator is not lighting after test blows, the 
Detector sensitivity should be increased by installation of SENS jumper;

- check adjustment correctness of the Detector with the closed cover.

Changeover of the Detector from «Adjustment» to «Normal» mode 

is  fulfilled  by  MODE  jumper  installation  (see  Table  3)  or  in  15  min 

automatically.

For monitoring the Detector availability, it is allowed to use electronic 

glass break simulator during adjustment.

Table 4

Glass thickness, mm

<3 

3...4

4...5

5...6

6...7

>7

Ball deflection angle for ordinary, 

armed and ornamental glass, 

0

30

35

40

45

50

55

Ball deflection angle for, 

hardened and laminated glass, 

0

45

50

55

60

65

70

- it is recommended to install the Detector at least 2 m height (see 

examples of installation in Figures

 

3 – 6);

- during joint operation with an active ultrasonic Detector, distance 

between Detectors must be not less than 1 m;

- the entire surface of the monitored glass should be available within 

the direct visibility of the Detector;

- distance (L) between the Detector and the farthest point of the 

monitored glass should not exceed 10 m;

- the Detector operation mode is set in accordance with Table 3.
Table 3

JUMPER

REMOVED

INSTALLED

SENS

MINIMUM

MAXIMUM

MODE

ADJUST

NORMAL

IND

OFF

ON

6 Installing the Detector

6.1 The Detector comprises cover and base (1) with installed printed 

circuit board (PCB) (3). Cover is fixed on a base by two lugs (9) and 
a latch (5). The base design includes openable holes (12) for wiring 
and a hole (2) for fastening a base to the mounting surface. PCB is 

fastened to the base by lugs (9) and screw (6).

Top view

Side view

L

L

90

о

45

о

120

о

6 m

6 m

Figure 1

5 Choosing the Detector Location

Before  installing  the  Detector,  get  acquainted  with  the  following 

requirements:

10 m

10 m

1

3

5

6

2

2

7

8

9

9

10

Jumper

Removed

Installed

Min

Max

Adjust

Normal

OFF

ON

SENS

MODE

IND

  SENS  MODE  IND

 +12V-

   Alarm   Tamp

11

12