31
INSTALLER
INSTALLER
3.15
Fitting the casing panels
To mount the panelling, proceed as follows:
− Open the pre-cut slots on the side panel (3) or (4) (de-
pending on which side you want to install the control
panel), in correspondence with the “oval” cable glands
of the control panel.
− Perforate the membranes of the control panel cable
grommets. Route the electrical cables through them and
insert the sensors in their sockets.
− Fasten the control panel (A) to the panelling using the
screws supplied.
4
A
3
− Fit the side panels (1, 2, 3, 4, 5, 6, 7 and 8) over the boiler's
top profiles.
4
6
8
2
3
1
5
7
− Screw the four screws (used as fixing points) into the
holes on the back of panels (7) and (8) (two per panel).
4
6
8
2
3
1
5
7
− Fit the upper panels (9, 10, 11, 12) and tighten eight screws
(used as fixing points) in the front part of the panels (two
per panel).