GENERAL INFORMATION

 

GENERAL INFORMATION

GENERAL INFORMATION

1.1 

General Safety Information

 

9

The boiler is delivered in separate crates. Check that it is 

complete, undamaged and as ordered as soon as you re-

ceive it. Report any discrepancies or damage to the dealer 

who sold it.

 

9

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to the 

highest standards in compliance with the instructions pro-

vided by 

R

 in this instruction manual, and that it con-

forms to all applicable laws and standards.

 

9

This product must only be used for the purpose for which it 

is designed and made, as specified by 

R

R

 declines 

all responsibility, contractual or other, for damage to prop-

erty or injury to persons or animals caused by improper in-

stallation, adjustment, maintenance or use.

 

9

If you notice any water leaking from the boiler, disconnect it 

immediately from the mains electricity supply, shut off the 

water supply, and notify your local 

R

’s Technical Assis-

tance Service or a qualified heating engineer immediately.

 

9

Periodically check that operating pressure in the water cir-

cuit is over 1 bar but below the maximum limit specified for 

the boiler. If this is not the case, contact Technical Assistance 

Service 

R

 or a professionally qualified heating engineer.

 

9

If the boiler is not going to be used for an extended pe-

riod of time, contact 

R

’s Technical Assistance Service or 

a qualified heating engineer to have it prepared for shut-

down as follows

 

− Switch the boiler OFF at the control panel

 

− Turn the main system switch "off"

 

− Close the fuel cock and heating circuit water cock

 

− Drain the central heating circuit if there is any risk of 

freezing.

 

9

The boiler must be serviced at least once a year.

 

9

This instruction manual is an integral part of the boiler. It 

must be kept safe and must ALWAYS accompany the boiler, 

even if it is sold to another owner or transferred to another 

user or to another installation. If you damage or lose this 

manual, order a replacement immediately from your local 

R

’s Technical Assistance Service.

1.2 

Precautions

The operation of any appliance that uses fuel, electrical power 

and water demands that a number of fundamental safety pre-

cautions be respected:

 

0

It is forbidden to use electrical devices or equipment, such 

as switches, appliances, etc. if there is a smell of gas or un-

burnt products. If so:

 

− Ventilate the room, opening doors and windows

 

− Close the fuel shut-off cock

 

− Report the fault immediately to the 

R

's Technical As-

sistance Service or a professionally qualified heating en-

gineer.

 

0

Do not touch the boiler while barefoot or wet.

 

0

Never clean or service the boiler without first disconnect-

ing it from the mains electricity supply by turning the main 

power switch and the control panel switch OFF.

 

0

Do not tamper with or adjust the safety or control devices 

without prior authorisation and instructions from the man-

ufacturer.

 

0

Do not plug or block the condensate drain outlet.

 

0

Never pull, disconnect, or twist the electrical cables coming 

from the appliance even if it is disconnected from the mains 

electricity supply.

 

0

Do not obstruct or restrict the vents in the room where the 

boiler is installed. Adequate ventilation is essential for cor-

rect combustion.

 

0

Do not expose the boiler to the elements. It is designed to 

work indoors.

 

0

Do not switch the boiler off if outdoor temperature drops 

below ZERO (risk of freezing).

 

0

Do  not  store  containers  of  flammable  substances  in  the 

room where the boiler is installed.

 

0

Do not allow children or persons with reduced physical, 

sensorial or mental abilities or with insufficient experience 

and knowledge to operate this system without proper su-

pervision from the person responsible for its safe use.

 

0

Do not dispose of packaging material into the environment, 

or leave it within the reach of children, since it can become 

a potential hazard. Dispose of packaging material in com-

pliance with applicable legislation.

General information

Содержание TAU 2100 N

Страница 1: ...cod Doc 0096458 rev 0 10 2019 TAU 2100 2600 N EN INSTALLATION TECHNICAL ASSISTANCE SERVICE AND SYSTEM MANAGEMENT MANUAL...

Страница 2: ...are specially trained to keep your boiler efficient and cheap to run They also stock any original spare parts that might be required This instruction manual contains important instructions and precaut...

Страница 3: ...11 2 5 Useful information 12 3 INSTALLER 13 3 1 Unpacking the product 13 3 2 Overall dimensions and weights 14 3 3 Handling 15 3 4 Installation premises 16 3 5 Positioning of sensor sockets 17 3 5 1 W...

Страница 4: ...nd must ALWAYS accompany the boiler even if it is sold to another owner or transferred to another user or to another installation If you damage or lose this manual order a replacement immediately from...

Страница 5: ...trol panels of the RIELLOtech range which take into account the dif ferent operating functions the needs of the heating system and the various devices used on them Note for additional information see...

Страница 6: ...n window with pressure meas urement fitting 3 Door 4 Body interior inspection flange 5 Outlet 6 Safety device fitting 7 Heating return high temperature 8 Combustion chamber 9 Heating return low temper...

Страница 7: ...20164364 20163867 RLS 410 M MX 20087649 x 20163867 RLS 310 E MX 20087643 x 20164364 20163867 RLS 410 E MX 20087645 x 20163867 GAS PREMIX RX 2500 S E 20148881 x 20164364 20163866 RX 3000 S E 20148882...

Страница 8: ...burner s own manual RS gas RLS gas Light oil burner RX premix burner If you are installing a new boiler but re using an old burner always perform the following checks Make sure that the performance o...

Страница 9: ...ow tem perature mode n1 with return 30 C GCV NCV 97 9 97 9 108 7 108 7 Losses from stack for sensible heat Qmax 1 5 Losses from casing with burner on 0 3 Constant pressure drop P max 0 2 Flue gas temp...

Страница 10: ...ust the timer thermostat if installed or the tempera ture control to the desired temperature 20 C Turn the boiler s mains power switch ON Turn the control panel power switch ON and make sure that the...

Страница 11: ...gents 0 0Never clean the boilerwithout first disconnecting it from the mains electricity supply by turning the mains power switch and the control panel switch OFF 9 9The combustion chamber and flue pi...

Страница 12: ...information Seller Mr Address Tel Technical Assistance Service Mr Address Tel Installer Mr Address Tel Date Work done Fuel oil supplier Mr Address Tel Date Quantity supplied Date Quantity supplied Da...

Страница 13: ...velope H containing Instruction manual Technical data plate adhesive to be applied to the panelling when installing the boiler Hydraulic test certificate Conventional warranty conditions 9 9The instru...

Страница 14: ...LER INSTALLER 3 2 Overall dimensions and weights P P1 H1 H L1 L DESCRIPTION TAU N 2100 2600 L 1750 1850 mm L1 1800 1900 mm P 4020 4425 mm P1 3612 4024 mm H 1945 2070 mm H1 1870 2128 mm Net weight 4750...

Страница 15: ...art of the boiler Proceed as follows to move the boiler and remove the packaging Remove the protective film Move the boiler to the place of installation use a crane for lifting and using only the lift...

Страница 16: ...the front door opened without having to remove the burner 9 9For Belgium boilers must be installed according to the NBN D51 003 standard the NBN B61 001 standard output 70 kW 9 9When installing the b...

Страница 17: ...Flow sensor socket connector 1 2 70mm 150mm 70mm 150mm 2 Overtemperature protection 1 2 120mm 190mm 120mm 190mm 3 Return sensor socket connector 1 2 120mm 150mm 120mm 150mm 4 Flue gases sensor socket...

Страница 18: ...60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 TAU N 2100 TAU N 2600 Flow rate m3 h The curves refer to a density of 9...

Страница 19: ...rst time once it is filled and the air expelled it should never need to be topped up again Systems should also be operated at maximum working tem perature the first time they are started up in order t...

Страница 20: ...all applicable legislation 9 9Circuits filled with anti freeze must be fitted with water disconnectors DESCRIPTION TAU N 2100 2600 1 System delivery DN200 PN6 DN200 PN6 DN 2 2nd return High temperatur...

Страница 21: ...9 9Domestic hot water and central heating circuits must be completed with expansion vessels of adequate capacity and suitable correctly sized safety valves The discharge of safety valves and applianc...

Страница 22: ...RN LT RETURN CENTRAL HEATING SUPPLY MAKE UP WATER 1 2 1 2 1 2 1 Boiler 2 Burner 3 Disconnect valves 4 Central heating system pump 5 Non return valves 6 Automatic vent valve 7 Boiler safety valve 8 Boi...

Страница 23: ...AL HEATING SUPPLY 1 2 1 2 1 Boiler 2 Burner 3 Disconnect valves 4 Central heating system pump 5 Non return valves 6 Automatic vent valve 7 Boiler safety valve 8 Boiler drain cock 9 Y filter 10 Pressur...

Страница 24: ...N LT CENTRAL HEATING RETURN CENTRAL HEATING SUPPLY 1 2 1 2 1 2 1 Boiler 2 Burner 3 Disconnect valves 4 Central heating system pump 5 Non return valves 6 Automatic vent valve 7 Boiler safety valve 8 Bo...

Страница 25: ...1 2 1 2 1 2 COLD WATER INLET 1 Boiler 2 Burner 3 Disconnect valves 4 Central heating system pump 5 Non return valves 6 Automatic vent valve 7 Boiler safety valve 8 Boiler drain cock 9 Y filter 10 Pre...

Страница 26: ...top fitting H2 O L 3 10 Neutralising the condensate TYPE N3 NEUTRALISATION KIT The TYPE N3 neutralisation units were designed for systems equipped with the central heating plant condensate outlet trap...

Страница 27: ...he boiler condensate drain fitting using the flexible hose C supplied This condensate drain hose is specially made to prevent combustion fumes escaping into the atmosphere The outlet fitting B of the...

Страница 28: ...e condensate boiler condensate at discharge or neutralisation of condensate 9 9The stack must guarantee the minimum draught specified by applicable technical standards assuming zero pressure at the co...

Страница 29: ...y If you need to reverse the direction of opening remove the boil er s side panel and proceed as follows 9 9Check that the main locking screws 1 are fully tightened 1 Remove the snap ring 2 and the th...

Страница 30: ...y a connection point is pro vided in the centre of the frame to be connected to an effective earthing system Proceed as follows Unscrew the nut and washer 1 from the earth terminal Attach the earth ca...

Страница 31: ...l panel cable grommets Route the electrical cables through them and insert the sensors in their sockets Fasten the control panel A to the panelling using the screws supplied 4 A 3 Fit the side panels...

Страница 32: ...e lower profile of the rear panel 14 hook the profile to the pro vided pins and fix it with two self threading screws 14 Fit the central rear panels 15 16 inserting them from the sides to hook them to...

Страница 33: ...on en condensafvoerleidingen MINSTENS EENMAAL PER JAAR volgens de aanwijzingen in de handleiding voor gebruik en onderhoud Controlar y limpiar el sif n y las tuber as de evacuaci n condensaci n ANUALM...

Страница 34: ...ly bled The condensate discharge siphon has been filled with water The mains power connections to the boiler and its ac cessories burner pump control panel thermostats etc have been properly made 9 9T...

Страница 35: ...formed properly Check that all the electrical connections shown on the control panel wiring diagrams have been performed properly 4 3 Checks during and after initial start up Once the boiler has start...

Страница 36: ...ch OFF Close all the gas cocks Door opening To open the door simply completely unscrew the main locking nuts 1 that support themselves on the structure 1 To avoid dangerous leaks of combustion gases t...

Страница 37: ...racket B If one of these two conditions is not met proceed with the ad justment operations described on the following pages 2 1 B 9 9The pin 1 must not be used as a handle to close the door Door balan...

Страница 38: ...eted tighten the nut 8 completely Check the correct opening closing of the door 8 9 8 Door seal adjustment Loosen the screws 10 of the upper and lower hinge and adjust the position of the door until t...

Страница 39: ...ket wrench A 9 9Make sure that there are no leaks around the boiler door seal If you detect any leakage of fumes increase the tight ening of the door fixing bolts 9 9Make sure that the door is properl...

Страница 40: ...sumption Open the front door 1 Remove the turbulators 2 check their state of wear and the opening of the fins replace if necessary Clean the internal surfaces of the combustion chamber and the flue g...

Страница 41: ...trically disconnected Suitable personal protection equipment The water and fuel shut off valves closed In order to inspect the upper part of the boiler partially empty the boiler before opening inspec...

Страница 42: ...Air in the circuit Check the circuit pressure Check the vent valve The generator is at temperature but the heating system is cold Air in the circuit Bleed the circuit Pump malfunctioning Check unseize...

Страница 43: ...43 TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE...

Страница 44: ...lo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liabl...

Отзывы: