17
20148653
GB
Installation
5.1
Notes on safety for the installation
After carefully cleaning all around the area where the burner is to
be installed, and arranging for the environment to be illuminated
correctly, proceed with the installation operations.
5.2
Handling
The burner packaging includes a wooden platform, it is therefore
possible to handle the burner (still packaged) with a pallet truck
or fork lift truck.
5.3
Preliminary checks
Checking the consignment
Checking the characteristics of the burner
Check the identification label of the burner, showing:
the model (
A
)(Fig. 8) and type of burner (
B
);
the year of manufacture, in cryptographic form (
C
);
the serial number (
D
);
the data for electrical supply and the protection level (
E
);
the absorbed electrical power (
F
);
the types of gas used and the relative supply pressures (
G
);
the data of the burner's minimum and maximum output
possibilities (
H
) (see Firing rate).
Warning.
The burner output must be within the boiler's firing
rate.
the category of the appliance/countries of destination (
I
).
light oil maximum viscosity (
L
).
5
Installation
DANGER
All the installation, maintenance and disassembly
operations must be carried out with the electricity
supply disconnected.
ATTENTION
The installation of the burner must be carried out
by qualified personnel, as indicated in this manual
and in compliance with the standards and
regulations of the laws in force.
DANGER
The combustion air inside the boiler must be free
from hazardous mixes (e.g.: chloride, fluoride,
halogen); if present, it is highly recommended to
carry out cleaning and maintenance more
frequently.
ATTENTION
Burner handling operations can be highly
dangerous if not carried out with the greatest
attention: distance unauthorised personnel, check
integrity and suitability of the means available.
Check also that the area in which you are working
is empty and that there is an adequate escape
area (i.e. a free, safe area to which you can
quickly move if the burner should fall).
When handling, keep the load at not more than
20-25cm from the ground.
After positioning the burner near the installation
point, correctly dispose of all residual packaging,
separating the various types of material.
CAUTION
Before proceeding with the installation operations,
carefully clean all around the area where the
burner will be installed.
CAUTION
After removing all the packaging, check the
integrity of the contents. In the event of doubt, do
not use the burner; contact the supplier.
The packaging elements (wooden cage or
cardboard box, nails, clips, plastic bags, etc.)
must not be abandoned as they are potential
sources of danger and pollution; they should be
collected and disposed of in the appropriate
places.
ATTENTION
A burner label that has been tampered with,
removed or is missing, along with anything else
that prevents the definite identification of the
burner makes any installation or maintenance
work difficult.
Fig. 8
D9243
R.B.L.
GAS-KAASU
GAZ-AEPIO
0085
RIELLOS.p.A.
I-37045Legnago(VR)
CE
HEIZÖLFUEL
A
B
C
E
D
F
H
G
G
H
I
L
Содержание RLS 100
Страница 2: ...Translation of the original instructions ...
Страница 55: ...53 20148653 GB Appendix Electrical panel layout 0 1 2 1 2 3 3 3 4 3 5 3 3 3 3 3 3 3 63 6 6 3 3 4 3 ...
Страница 56: ...20148653 54 GB Appendix Electrical panel layout 0 1 1 1 ...
Страница 57: ...55 20148653 GB Appendix Electrical panel layout 0 1 1 1 2 2 ...
Страница 58: ...20148653 56 GB Appendix Electrical panel layout 0 1 2 1 3 3 0 4 0 3 5 6 7 6 7 8 99 8 99 6 7 4 2 1 8 6 6 RLS 70 ...
Страница 60: ...20148653 58 GB Appendix Electrical panel layout 0 1 2 1 3 3 0 4 0 3 5 6 7 6 7 8 99 8 99 6 7 4 2 1 6 6 RLS 130 ...
Страница 62: ......
Страница 63: ......