Residence Condens IS n
18
ENGLISH
19
DESCRIPTION
30 IS n
Losses for a 45°/90° bend
m
1,3/1,6
Hole in wall (diameter)
mm
105
Concentric flue gas outlet pipes
Diameter
mm
80-125
Maximum length
m
14,85
Losses for a 45°/90° bend
m
1/1,5
Hole in wall (diameter)
mm
130
Twin flue gas outlet pipes
Diameter
mm
80
Maximum length
m
42+42
Losses for a 45°/90° bend
m
1/1,5
Installation B23P–B53P
Diameter
80
Maximum discharge length
mm
80
Collective smoke pipes under pressure (with specific accessory only)
Max pressure allowed in the smoke pipe when installed with collective smoke pipes
Pa
50 (**)
NOx class
5
Emission values at max-min gas flow rate (***)
G20
G31
Maximum
CO s.a. lower than
ppm
190
200
CO
2
%
9,0
10,0
NOx s.a. lower than
ppm
40
40
Flue gas temperature
°C
65
67
Minimum
CO s.a. lower than
ppm
25
25
CO
2
%
9,0
10,0
NOx s.a. lower than
ppm
40
40
Flue gas temperature
°C
60
58
DHW functions refer only if a water tank is connected (accessory available on request).
(+) The installation of this product is allowed only in the destination Countries contained in the data plate, regardless of the present translation
language.
(**) Applicable with G20 gas only
(***) Check performed with concentric pipe Ø 60-100 - length 0.85m - water temperature 80-60°C
MULTIGAS TABLE
DESCRIPTION
Methane gas (G20)
Propane (G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m
3
S
45,67
70,69
Net Calorific Value
MJ/m
3
S
34,02
88
Supply nominal pressure
mbar
mm C.A.
20
203,9
37
377,3
Supply minimum pressure
mbar
mm C.A.
10
102,0
Residence Condens 30 IS n
Number of diaphragm holes
N°
1
1
Diaphragm holes diameter
Ø mm
6,0
4,6
Burner diameter
mm
63
63
Burner length
mm
110
110
CH maximum gas capacity
Sm
3
/h
2,64
kg/h
1,94
DHW maximum gas capacity
Sm
3
/h
3,17
kg/h
2,33
CH minimum gas capacity
Sm
3
/h
0,63
kg/h
0,47
DHW minimum gas capacity
Sm
3
/h
0,63
kg/h
0,47
Number of fan rotations with slow ignition
rpm
3.300
3.300
Maximum number of CH fan rotations
rpm
4.700
4.700
Maximum number of DHW fan rotations
rpm
5.600
5.600
Minimum number of CH fan rotations
rpm
1.400
1.400
Minimum number of DHW fan rotations
rpm
1.400
1.400
Minimum number of fan rotations with collective pipes under pressure
rpm
1.900
NOT APPLICABLE
The data indicated must not be used to certify the system; for certification, use the data indicated in the “System handbook” measured during
first ignition.
All the pressure values are measured with the compensation socket disconnected (if present).