background image

GENERAL

5

SAFETY PRECAUTIONS

As soon as you open the packaging, check imme-
diately that the contents are all present and undam-
aged. Contact the 

reseller from whom you 

purchased the product if you notice any problems.

This 

KOMBI 

combination storage cylinder 

must be installed by a qualified installer. On com-
pletion of the installation, the installer must issue the 
owner with a declaration of conformity confirming 
that the installation has been completed to the high-
est standards in compliance with the instructions 
provided by 

in this instruction manual, and 

that it conforms to all applicable laws and stand-
ards.

This 

KOMBI 

combination storage heater must 

only be used for the purpose specified by 

and 

for which it is designed. The manufacturer declines 
all responsibility, contractual or other, for damage to 
property or injury to persons or animals caused by 
improper installation, adjustment, maintenance or 
use.

If you notice any water leaking from the cylinder, 
disconnect it immediately from the mains electric-
ity supply, shut off the water supply, and notify your 

Technical Assistance Centre or a qualified 

technician immediately.

This combination storage cylinder must be serviced 
at least once a year.

Do not allow children or infirm persons to operate 
the combination storage cylinder unsupervised.

Do not touch the combination storage cylinder when 
barefoot or wet.

Never clean or service the combination storage 
cylinder without first disconnecting it from the mains 
electricity supply by turning the main power switch 
and the control panel switch OFF.

Do not interfere with any control devices without 
specific authorisation and instructions from the 
manufacturer.

Never pull, disconnect, or twist the electrical cables 
coming from the appliance even if it is disconnected 
from the mains electricity supply.

The operation of any appliance that uses electrical power and water demands that a number of fundamental safety 
precautions be respected. In particular:

If the combination storage cylinder is not going to 
be used for an extended period of time, prepare it 
for shut-down as follows:

 

-  Turn the system’s main power switch OFF

 

-  Drain the solar water circuit

 

-  Close the fuel cock and heating water cock

 

-  Drain the central heating circuit and domestic hot 

water circuit if there is any risk of freezing

Anti-freeze (propylene glycol) is available separate-
ly and must be mixed with water in a percentage 
varying from 30% to 50% as instructed in the rel-
evant 

r

 di messa in servizio e manutenzione.

Only fill the solar heating system with water and 
glycol premixed in the percentages specified in the 

installation and maintenance manual.

This instruction manual is an integral part of the 
appliance. It must be kept safe and must ALWAYS 
accompany the appliance, even if it is sold to anoth-
er owner or transferred to another user or to another 
installation. If you damage or lose this manual, order 
a replacement immediately from your local 

Technical Assistance Centre.

GENERAL SAFETY INFORMATION

Do not expose the combination storage cylinder to 
the elements. It is not designed for use outdoors.

Do not leave packaging material within the reach of 
children, since it can become a potential hazard.

If the pressure in the solar heating circuit drops, do 
not top up with water alone, since this increases the 
risk of damage from freezing.

Do not use connections or safety devices or fittings 
(expansion vessels, pipes, insulation) that are not 
specifically designed and tested for use in solar 
heating installations.

Содержание KOMBI 1000

Страница 1: ...cod 20145353 rev 1 05 2018 KOMBI EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Страница 2: ...2 RANGE MODEL CODE KOMBI 800 20145308 KOMBI 1000 20145313...

Страница 3: ...l are specially trained to keep your storage cylinder efficient and cheap to run Technical Assistance Centres also stock any original spare parts that might be required This instruction manual contain...

Страница 4: ...hnical specifications 8 Accessories 9 Water circuit 10 INSTALLATION Unpacking the product page 11 Dimensions and weight 11 Handling 12 Assembly of the insulation and the lining 13 Place of installatio...

Страница 5: ...ions from the manufacturer aNever pull disconnect or twist the electrical cables coming from the appliance even if it is disconnected from the mains electricity supply The operation of any appliance t...

Страница 6: ...ITALY ACCUMULO COMBINATO PR PARATEUR SOLAIRE MIXTE M Mod le odello M N fabrication atricola C Code odice A Ann e de fabrication nno fabbricazione Capacit serpentino sanitario Capacit du serpentin san...

Страница 7: ...mperature 10 Magnesium anode 11 Flange 12 Cylinder cover 13 Flange cover 14 Domestic hot water recirculation 15 Domestic hot water outlet 16 Domestic cold water in 17 Domestic hot water probe well 18...

Страница 8: ...Flange diameter external internal 280 205 mm Probe well diameter 1 2 Coil water capacity 16 19 l Coil heat exchange surface area 2 80 3 16 m2 Power absorbed by coil 76 92 kW Continuous production of d...

Страница 9: ...GENERAL 9 COIL pressure drop PRESSURE DROP mbar FLOW RATE l h 600 700 800 900 1000 1100 500 400 300 200 100 0 0 1000 2000 3000 4000 5000 6000 Mod 1000 Mod 800...

Страница 10: ...lation instructions for the water outlet and return kit EAF Domestic cold water inlet RL DHW recirculation UAC Domestic hot water outlet MC1 Outlet from boiler 1 high temperature MC2 Outlet from boile...

Страница 11: ...lied separately from the structural work and are to be assembled upon receiving the product as described in the paragraph Assembly of the insulation and the lining The following items are delivered in...

Страница 12: ...cylinder from the pallet Place a platform of about half the height of the pallet near the storage cylinder Make sure the platform is able to support the weight of the storage cylinder Remove the brac...

Страница 13: ...hout closing completely leave one tooth open Put the washers on the attachments 4 Cut the top insulation 5 and apply it Apply the insulation 6 Close the interlocking flaps 3 completely which were prev...

Страница 14: ...ding free access to the space where the combination storage cylinder is to be installed When installing r KOMBI combination storage cylin ders in old systems or systems requiring modernisation always...

Страница 15: ...d thermostatic mixer valve Water fittings have the following specifications We recommend that you install isolating valves in the outlet and return lines MC1 Outlet from boiler 1 1 1 4 F MC2 Outlet fr...

Страница 16: ...it the domestic hot water outlet temperature b If the pressure in the solar heating circuit drops do NOT top up with water but use the proper water glycol mix Risk of freezing b All piping collectors...

Страница 17: ...boiler or hot water generator Installers must ensure proper installation and functioning in compliance with all applicable legislation It is essential to perform the following checks before starting...

Страница 18: ...er see the instruction manual for the controller Start up the boiler to provide auxiliary heating for the combination storage cylinder 1 2 3 4 5 0 6 Once the system has been started up perform the fol...

Страница 19: ...rate If the combination storage cylinder is not going to be used for an extended period of time prepare it for shut down as follows Shut down the boiler as instructed in its own manual Turn the syste...

Страница 20: ...n marks use a cloth damped in a 50 mix of water and denatured alcohol or a suitable cleaning product Dry the combination storage cylinder after cleaning it aDo not use abrasive products petrol or trie...

Страница 21: ...ting system There are problems with the storage cylinder s thermostat The pump is malfunctioning There is lime scale or sludge in the tank Water temperature is low Check the setting and condition of t...

Страница 22: ...o low Set a T of 8 10 C There is lime scale or sludge in the tank Check and clean as necessary The flow rate is too high Reduce pump speed and turn the flow rate adjustment screw on the valve group to...

Страница 23: ......

Страница 24: ...lo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liabl...

Отзывы: