51
To activate/deactivate the ONE HOUR
BOOSTER function, from the HOME
screen press the BACK button (if
active, the MAN icon is displayed).
SET
PROG
RESET
3.6.3
SEMI-AUTOMATIC FILLING
function
The SEMI-AUTOMATIC FILLING function
allows the correct system pressure to
be restored and is only available for
boilers equipped with the relevant
function (if OTBus connection available
between the WiFi Box and the boiler
or the RF receiver and the boiler or the
Hi, Comfort T100
and the boiler, if pro-
vided for by the OTBus protocol).
If the rIE alarm is quick flash (0,5 sec.)
on the HOME screen in the room tem-
perature field,
SET
PROG
RESET
ESC
MODE
press the ESC/MODE button and hold for
5 seconds to start semi-automatic fill-
ing (the message rIE will stop flashing
and remain on). When releasing the
button ESC/MODE the rIE message starts
flashing slowly (2 secs) until the end of
the function.
ESC
MODE
Once the system pressure has been re-
stored, the
Hi, Comfort T100
automati-
cally returns to the normal HOME screen
display.
9
If the SEMI-AUTOMATIC FILLING
function is not carried out within
90 seconds, the rIE alarm flashes
quickly (1sec.) and is displayed on
the HOME page again.
3.6.4
KEY-LOCK function
In the main menu press the FORWARD
and UP
buttons for 5 seconds si-
multaneously to display the request for
password entry.
SET
PROG
RESET
ESC
MODE
If the password has never been set, the
symbols "--" are displayed; set the new
password using the UP
and DOWN
buttons and press SET to confirm
and return to the main menu with the
buttons disabled.
The new password is then saved. The
password value must be between "0"
and "99". The default value is not set
"--".