INSTALLATION AND TECHNICAL SERVICE INSTRUCTIONS

Содержание 20158936

Страница 1: ...03 2021 cod Doc 0093014 rev 1 AMD P SERIES R32 EN INSTALLATION AND TECHNICAL SERVICE INSTRUCTIONS ...

Страница 2: ...nstallation Thank you again and keep up the good work RIELLO RANGE Model Code AMD 100 PB 20158936 AMD 125 PB 20158937 AMD 140 PB 20158938 AMD 125 PC 20159407 AMD 140 PC 20159408 ACCESSORIES For the complete list of accessories and the information relating to their usage combinations please refer to the catalogue COMPLIANCE R AMD P heat pumps are compliant with the following European Directives Low...

Страница 3: ...MATION p 4 1 1 General Notices p 4 1 2 Safety precautions p 4 1 3 Unit description p 5 1 4 Safety and adjustment devices p 5 1 5 Identification p 5 1 6 Layout p 5 1 7 Technical specifications p 6 1 8 Cooling circuit p 7 2 INSTALLATION p 8 2 1 Receiving the product p 8 2 2 Labels positioning p 8 2 3 Dimensions and weight p 8 2 4 Storage p 9 2 5 Handling and removal of the packing p 9 2 6 Place of i...

Страница 4: ...ervice and do not perform any interventions upon the device on your own 9 The units contain refrigerant gas operate carefully so as to avoid damaging the gas circuit and the fin bank 9 Any gas leaks indoors can generate toxic gases if they come into contact with naked flames or high temperature bodies in case of leaks please air the rooms thoroughly 9 Do not place any inflammable object spray cans...

Страница 5: ...nsmitting the detected va lue to the control panel in order to control the operation of the outdoor unit and regulate the room temperature 9 Safety device replacement must be carried out by R Technical Support Service using only original components Please refer to the spare parts catalogue 0 0 IT IS FORBIDDEN to operate the device with faulty safety sys tems 1 5 Identification The unit can be iden...

Страница 6: ... 1500 1500 1500 Maximum speed rpm 900 1070 1180 1140 1140 Medium speed rpm 840 960 1080 1060 1060 Minimum speed rpm 780 880 990 980 980 Superminimum speed rpm 750 850 930 900 900 Cooling sound levels Superminimum sound pressure 1 dB A 31 37 38 37 37 Minimum sound pressure 1 dB A 33 42 43 42 42 Medium sound pressure 1 dB A 36 45 46 44 44 Maximum sound pressure 1 dB A 39 49 50 48 48 Maximum sound po...

Страница 7: ... General information 1 8 Cooling circuit A Outdoor unit B Indoor unit 1 Refrigerant connections 2 Room air probe 3 Heat exchanger 4 Heat exchanger sensor 5 Electric fan 6 Connection pipes B A 1 3 4 2 6 5 ...

Страница 8: ...ion s book for the installer and for the Technical Service in English user instruction booklet in Italian user instruction booklet in English Warranty Spare parts labels contact sheets It is also supplied as kit wired control panel Control panel cable no 2 screws for control panel support fastening flare nut for liquid pipe flare nut for gas pipe insulating material for liquid piping insulating ma...

Страница 9: ...remove the document envelope take out the device by lifting it up remove accessories and control panel from the fan com partment 9 In manual operation it is compulsory to respect always the maximum weight per person provided for by the national laws and standards 9 Handle with care 9 The packing material must not be disposed of in the sur rounding environment and must be kept out of children reach...

Страница 10: ...e locations with aggressive or explosive atmospheres or with inflammable fluids direct exposure to sunlight and proximity to heat sources humid locations or positions where the unit could come into contact with water environment containing oil vapours locations with high frequency contamination 9 Avoid placing the unit less than 1 metre away from radio and video systems 9 A detachable section cut ...

Страница 11: ...cal Support Service Ceiling mounting 1 Threaded rods 2 Fastening nut 3 Washer 1 2 3 M10 position the support rods and fix them properly to the bearing structures place the nuts on the threaded bars hook the unit to the threaded bars regulate the height of installation of the unit center the unit over the opening regulate the unit s position horizontally tighten the fastening nut 9 Seal the nuts wi...

Страница 12: ...DEL 125 140 PC A D C B Model 125 PC 140 PC Air duct dimensions A mm 1052 B mm 1163 C mm 353 D mm 312 position the channels in conjunction with the connectors on the unit fasten to the prepared holes use suitable screws apply thermal insulating material on the joints Connect the fan motor according to the length of the delivery duct 0 5 m use the white connector default 0 5 m length delivery 2 m us...

Страница 13: ...L 125 140 PC 1 Gas line connection 2 Liquid line connection 1 A B C 2 Model 125 PC 140 PC Refrigeration characteristics A mm 160 B mm 100 C mm 130 D mm 194 9 For indications concerning distances and differences in height of connection pipes refer to the matching outdoor unit manual 9 Use clean hoses Make sure the inside is free of dust resi dues water 9 Avoid the entry of uncondensable gases air i...

Страница 14: ... 8 29 bring line ends with flare connection close to their cou pling on the unit manually rotate the flare nuts by 3 4 turns tighten the connections using a spanner and a counter spanner 9 Use a torque wrench to tighten so as to prevent damage to flare nuts and gas leaks 9 Use equipment suitable for the system refrigerant 9 Avoid using the refrigerant oil on the external part of the flaring 9 Avoi...

Страница 15: ...erial used resists to temperatures up to 120 C For liquid pipes ensure that the material used resists to temperatures up to 70 C 2 11 Condensate discharge connection R AMD P is equipped with condensate drain pan which is produced during cooling operation and which must be con veyed to a place suitable for drain Models 100 125 140 PB are provided with a condensate drain pump but it is possible to u...

Страница 16: ...charge attachment 1 Model 125 PC 140 PC Refrigeration characteristics Condensate discharge attachment Ø mm 25 Connections 1 Hose clamp 2 Condensate discharge pipe supplied 3 Adapter 4 Drainage pipe 5 Insulating material 6 Condensate discharge attachment 1 2 3 6 5 4 connect the condensate drain pipe connect a rubber drainage pipe direct it toward a suitable place for discharge 100mm 3 keep a slope ...

Страница 17: ...ur poses 9 Ensure that all joints are properly sealed so as to prevent water leaks 9 The drainage pipe must be insulated for sections running inside houses in order to prevent condensate formation on its surface After performing the connection disconnect CN4 connector jumper the CN13 connector 9 For more information refer to the paragraph Wiring dia gram p 18 Drainage check After electrical connec...

Страница 18: ...TE RECEIVER Y G GALLEGGIANTE MOTORE VENTILATORE FAN MOTOR FUSIBILE TUBAZIONE SONDA TEMP AMBIENTE SONDA TEMP TELECOMANDO RICEVITORE ALLʼUNITÀ ESTERNA COMANDO A FILO CONDENSA POMPA SCARICO MOTORE ARIA ESTERNA SEGN ALLARME ESTERNO 9 The dotted parts are optional 9 Do not change SW01 and SW03 Dip Switch position without reading the instruction inside the paragraph Microswitch setting p 25 9 E A O exte...

Страница 19: ... outdoor unit CN20 M FRELAY FOR FRESH AIR MOTOR CN7 Contact rating 230 VAC 3A E A 0 ALLʼUNITÀ ESTERNA Reattore GALLEGGIANTE VENTILATORE TELECOMANDO RICEVITORE CONDENSA POMPA SCARICO FUSIBILE TUBAZIONE SONDA TEMP AMBIENTE SONDA TEMP MOTORE COMANDO A FILO MOTORE SEGN ALLARME ARIA ESTERNA ESTERNO TRASFORMATORE SCHEDA ELETRONICA PRINCIPALE 9 The dotted parts are optional 9 Do not change SW01 and SW03 ...

Страница 20: ...10 FUSIBILE Reattore VENTILATORE MOTORE COMANDO A FILO ALL UNITÀ ESTERNA COMANDO A FILO MOTORE SEGN ALLARME ARIA ESTERNA ESTERNO TUBAZIONE SONDA TEMP AMBIENTE SONDA TEMP TELECOMANDO RICEVITORE SCHEDA ELETRONICA PRINCIPALE CONTATTO FINESTRA 9 The dotted parts are optional 9 Do not change SW01 and SW03 Dip Switch position without reading the instruction inside the paragraph Microswitch setting p 25 ...

Страница 21: ...anel access panel 1 MODEL 125 140 PC 1 Electric panel access panel 1 unscrew the fastening screws remove the electric panel access panel unscrew the fastening screw remove the terminal board cover panel make the electric connections according to the diagrams on the installation booklet of the matching outdoor unit connect the wire remote control panel when indicated in the following chapter Contro...

Страница 22: ...thing system of a telephone line Using an improper earthing system can cause electric shocks 2 14 Control panel Control setting and programming operations are carried out with the control panel The electronics modulates the device operation according to the temperatures detected by the probes inside the indoor and out door units 2 14 1 Installation 2 14 1 1 Place of installation The location of th...

Страница 23: ...The connection is polarised respect the correct sequence Mandatory items make sure that the electrical power supply system is com pliant with the current national safety standards for any electrical intervention always refer to the wiring diagrams contained within this booklet take anti static precautions in case of weather conditions where humidity is less than 40 9 Electric connections shall be ...

Страница 24: ...ailable only for some models Air flow downwards function available only for some models Other icons Displaycurrent time Alarm display Timersettingvalue Switch on timerenabled Switch off timerenabled Cassette deflectors function enabled Parental lockfunction activated Lockfunction activated Centralized control enabled Fan speed set Automatic speed enabled Setting mode enabled Alarm mode enabled Fun...

Страница 25: ...ally if the contact is clean Roomcard it closes but can be controlled by a remote control ON enabled the unit turns off automatically if the contact is clean Roomcard opens and can not be controlled by a remote control when the contact is clean Roomcard closes the unit is ready to be restarted by a remote control 9 Contact Roomcard is bridged by factory default 9 For the location of the free conta...

Страница 26: ...ic pressure It can be selected the static pressure values through the control panel 9 Function available for some models only Available static pressure Pa Mod Available static pressure level setting 1 2 3 4 5 6 7 8 9 10 100 PB 25 37 50 70 90 100 110 120 130 150 125 PB 25 37 50 70 90 100 110 120 130 150 140 PB 25 37 50 70 90 100 110 120 130 150 125 PC 40 50 60 80 100 120 150 180 200 250 140 PC 40 5...

Страница 27: ...aintenance Routine maintenance is fundamental for keeping the equip ment efficient safe and reliable It can be performed periodi cally by the Technical Support Service whose staff is technically qualified and can use genuine spare parts if necessary 9 Original conditions must be restored after performing the required maintenance operations 9 All described operations MUST be carried out under the f...

Страница 28: ...tormalfunction Blinking AMD 125 PB AMD 140 PB LED3 Display Description Remarks 1 01 Room probe fault Sensordisconnected Broken sensor Incorrect position Probe short circuit 2 02 Exchangerprobe fault Sensordisconnected Sensordamaged Incorrect position Probe short circuit 4 04 Microprocessormalfunction Microprocessordisconnected Microprocessorfault Programming error Main electronic board damaged 7 0...

Страница 29: ...n errorbetween indoorunit and outdoorunit Wrong connection Disconnected orinterrupted connection cables Incorrect setting of the unit address Main electronic board damaged 8 07 Communication errorbetween unit and control panel Wrong connection Disconnected orinterrupted connection cables Main electronic board damaged 12 0C Malfunction condensation drain system Pump disconnected Incorrect pump posi...

Страница 30: ...g and disposal 4 DISPOSAL Packaging materials shall be disposed of separately so as to re cover and recycle them At the end of its service life the device shall be disposed of according to the existing legislation ...