34
START CONDENS 25 - 29 Kis
Description
Methane gas (G20)
Propane (G31)
Maximum number of heating fan rotations
rpm
4.900
4.900
Maximum number of DHW fan rotations
rpm
6.100
6.100
Minimum number of heating fan rotations
rpm
1.400
1.400
Minimum number of DHW fan rotations
rpm
1.400
1.400
Start Condens 29 Kis
Number of diaphragm holes
N°
1
1
Diaphragm holes diameter
Ø mm
5.1
3.9
Heating maximum gas capacity
Sm
3
/h
kg/h
2.64
-
-
1.94
DHW maximum gas capacity
Sm
3
/h
kg/h
3.07
-
-
2.25
Heating minimum gas capacity
Sm
3
/h
kg/h
0.63
-
-
0.47
DHW minimum gas capacity
Sm
3
/h
kg/h
0.63
-
-
0.47
Number of fan rotations with slow ignition
rpm
4.000
4.000
Maximum number of heating fan rotations
rpm
5.300
5.200
Maximum number of DHW fan rotations
rpm
6.200
6.000
Minimum number of heating fan rotations
rpm
1.400
1.400
Minimum number of DHW fan rotations
rpm
1.400
1.400
9.3 - ErP data table
Parameter
Symbol
Start Condens
25 Kis
Start Condens
29 Kis
Unit
Seasonal energy efficiency class for heating
A
A
Energy efficiency class for water heating
A
A
Nominal output
Pn
20
24
kW
Seasonal energy efficiency for heating
ηs
93
93
%
Useful heat output
At nominal heat output and in high temperature mode (*)
P4
19,5
24,5
kW
At 30% of nominal heat output and in low temperature mode (**)
P1
6,5
8,1
kW
Efficiency
At nominal heat output and in high temperature mode (*)
η4
87,7
87,6
%
At 30% of nominal heat output and in low temperature mode (**)
η1
97,8
97,8
%
Auxiliary electric consumption
With full load
elmax
29,0
38,0
W
With partial load
elmin
10,4
13,1
W
In standby
PSB
2,4
2,4
W
Other parameters
Heat losses in standby
Pstby
40,0
35,0
W
Energy consumption of the pilot flame
Pign
-
-
W
Annual energy consumption
QHE
53
63
GJ
Sound power level inside
LWA
50
55
dB
Nitrogen oxide emissions
NOx
30
30
mg/kWh
production
Load profile declared
XL
XL
Daily electricity consumption
Qelec
0,183
0,197
kWh
Annual electricity consumption
AEC
40
43
kWh
Energy efficiency for water heating
ηwh
85
84
%
Daily fuel consumption
Qfuel
22,920
23,021
kWh
Annual fuel consumption
AFC
17
17
GJ
(*) in high temperature mode: 60°C on return and 80°C on delivery.
(**) in low temperature mode: Return temperature 30°C.
NOTE
With reference to Delegated Regulation (EU) No 811/2013, the data represented in the table may be used for the completion of the product
sheet and the labelling of ambient heating appliances, mixed heating appliances, the sets of ambient heating appliances, temperature control
devices and solar devices:
Outdoor probe connected in boiler
Component
Class
Bonus
External probe
II
2%
Control panel
V
3%
outdoor probe + command panel
VI
4%
Содержание 20114905