159
START CONDENS 25 - 29 Kis
marone
CN3
blu
V Hv
1
2
6
1
CN2
marrone
blu
2
1
3
5
4
B
D
A
C
1
2
4
3
OPE
OPE
rosa
blu
P
marrone
N L
230 V
M3
F
blu
blu
marrone
marrone
marrone
blu
7
1
CN9
P.A.
2
3
1
S.S.
F.L.
bianco bianco
rosso rosso
viola
viola
-t°
3V
2
N
1
San.
3
Risc.
nero (san.)
marrone (risc.)
blu
3
1
CN4
TSC2
blu
E.A.
marrone
giallo/verde
N
F
CN1
3
1 2
rosso (+)
blu (HS)
rosa (PWM)
grigio (-)
CN10
V Lv
1
4
1
12
CN11
bianco bianco
S.M.
-t°
-t°
S.R.
rosso rosso
-t°
S.F.
grigio
grigio
nero
T.L.A.
blu
blu
bianco
CN8
CN7
1
12
CN11
1
4
CN10
1
7
CN9
CN6
CN5
CN12
1
CN4
1
3
CN3
1
2
CN2
1
6
AKL05 GAR
CN1
1
FA1
FA2
arancione
E.R.
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
CN15
P3
P2
P1
CN13
CN14
SW1
P4
F1
3.15A T
[IT] - Schema elettrico
LA POLARIZZAZIONE L-N È CONSIGLIATA
A
Termostato ambiente: contatto privo di
tensione
B
Valvola gas
C
CN6 ove previsto
D
Fusibile 3.15A F
AKL05GAR
Scheda comando con visualizzatore
digitale integrato
P1
Potenziometro selezione off – estate –
inverno – reset / temperatura riscaldamento
P2
Potenziometro selezione set point
sanitario, abilitazione/disabilitazione
funzione PRERISCALDO (solo in
configurazione COMBI)
P3
Preselezione curve di termoregolazione
P4
Non usato
JP1
Abilitazione manopole frontali alla taratura
del solo massimo riscaldamento (MAX_
CD_ADJ)
JP2
Azzeramento timer riscaldamento
JP3
Abilitazione manopole frontali alla taratura
in service (MAX, MIN, MAX_CH, RLA)
JP4
Selettore termostati sanitario assoluti
JP5
Funzionamento solo riscaldamento con
predisposizione per bollitore esterno e
termostato
JP6
Abilitazione funzione compensazione
notturna e pompa in continuo
JP7
Abilitazione gestione impianti standard/
bassa temperatura
JP8
Abilitazione gestione flussostato (jumper
inserito)/flussimetro (jumper non inserito)
S.W.
Spazzacamino, interruzione ciclo di sfiato e
taratura quando abilitata
E.R.
Elettrodo rilevazione fiamma
F1
Fusibile 3.15A T
F
Fusibile esterno 3.15A F
M3
Morsettiera collegamenti esterni
P
Pompa
OPE
Operatore valvola gas
V Hv
Alimentazione ventilatore 230 V
V Lv
Segnale controllo ventilatore
3V
Servomotore valvola 3 vie
E.A.
Elettrodo accensione
TSC2
Trasformatore accensione
F.L.
Flussostato sanitario
S.S
. Sonda (NTC) temperatura circuito sanitario
P.A.
Pressostato acqua
T.L.A.
Termostato limite acqua
S.F.
Sonda fumi
S.M.
Sonda mandata temperatura circuito
primario
S.R.
Sonda ritorno temperatura circuito primario
CN1-CN15
Connettori di collegamento (CN6
kit sonda esterna/pannello comandi
– CN7 kit valvola di zona - CN5
termostato ambiente
[EN] -
Wiring diagram
L-N POLARISATION IS RECOMMENDED
Bianco=White • Blu=Blue • Grigio=Grey •
Marrone=Brown • Nero=Black • Rosso=Red •
Viola=Violet
A
Room thermostat jumper (voltage free
contact input)
B
Gas valve
C
CN6 when expected
D
Fuse 3.15A F
AKL05GAR
Control card with integrated digital
display
P1
Potentiometer to select off - summer -
winter – reset / heating temperature
P2
Potentiometer to select domestic hot water
set point, and enable/disable PREHEATING
function (in COMBI configuration only)
P3
Thermoregulation curve preselection
P4
Not used
JP1
Enable front knobs for calibration of
maximum heating only (MAX_CD_ADJ)
JP2
Heating timer reset
JP3
Enable front knobs for calibration in service
(MAX, MIN, MAX_CH, RLA)
JP4
Absolute domestic hot water thermostat
selector
JP5
Heating only function selection with
provision for external storage tank with
thermostat or probe
JP6
Enable night-time compensation function
and continuous pump
JP7
Enable management of low temperature/
standard installations
JP8
Enabling management of flow switch
(Jumper inserted )/flow meter (Jumper not
inserted)
S.W.
Chimney sweep, interruption of venting
cycle and calibration when enabled
E.R.
Flame detection electrode
F1
Fuse 3.15A
T
F
External Fuse 3.15A
F
M3
External connections terminal board
P
Pump
OPE
Gas valve operator
V Hv
Fan power supply 230 V
V Lv
Fan control signal
3V
3-way valve servomotor
E.A.
Ignition electrode
TSC2
Ignition transformer
F.L.
DHW flow switch
S.S
.
DHW circuit temperature (NTC) probe
P.A.
Water pressure switch
T.L.A.
Water limit thermostat
S.F.
Flue gases probe
S.M.
Delivery temperature probe on primary
circuit
S.R.
Return temperature probe on primary circuit
CN1-CN15
Connectors (CN6 external probe/
control panel kit – CN7 zone valve kit -
CN5 ambient thermostat
[FR] - Schéma électrique
LA POLARISATION L-N EST CONSEILLÉE
Bianco=
Blanc
• Blu=B
leu
• Grigio=G
ris
•
Marrone=Marron • Nero=Noir • Rosso=Rouge
• Viola=Violet
A
Shunt thermostat d’ambiance (contact sec)
B
Vanne gaz
C
CN6 si nécessaire
D
Fusible 3,15 A F
AKL05GAR
Carte de commande avec afficheur
numérique intégré
P1
Potentiomètre de sélection OFF – été
– hiver – réinitialisation/température
chauffage
P2
Potentiomètre de sélection point de
consigne sanitaire, activation/désactivation
fonction de PRÉCHAUFFAGE (uniquement
en configuration COMBI)
P3
Présélection courbes de régulation
thermique
P4
Non utilisé
JP1
Activation poignées avant haut réglage
chauffage maximal seul (MAX_CD_ADJ)
JP2
Remise à zéro du temporisateur
JP3
Activation des poignées avant au réglage
en service (MAX, MIN, MAX_CH, RLA)
JP4
Sélecteur des thermostats sanitaires
absolus
JP5
Fonctionnement chauffage seul avec pré-
équipement pour chauffe-eau extérieur et
thermostat
JP6
Activation de fonction de compensation
fonction de compensation nocturne et
pompe en continu
JP7
Activation de la gestion d’installations
standard/basse température
JP8
Activation de la gestion du fluxostat (jumper
inséré)/débitmètre (jumper non inséré
)
S.W.
Ramonage, interruption du cycle de purge
et réglage si activé
E.R.
Électrode de détection de flamme
F1
Fusible 3,15 A T
F
Fusible extérieur 3,15 A F
M3
Bornier de branchements extérieurs
P
Pompe
OPE
Opérateur vanne gaz
V Hv
Alimentation du ventilateur 230 V
V Lv
Signal de contrôle ventilateur
3V
Servomoteur vanne à 3 voies
E.A.
Électrode d’allumage
TSC2
Transformateur d’allumage
F.L.
Fluxostat sanitaire
S.S
.
Sonde (NTC) température circuit sanitaire
P.A.
Pressostat d’eau
T.L.A.
Thermostat limite d’eau
S.F.
Sonde de fumées
S.M.
Sonde refoulement temp. circuit primaire
S.R.
Sonde retour temp. circuit primaire
CN1-CN15
Connecteurs de branchement (CN6
kit sonde extérieure/panneau de
commande – CN7 kit vanne de zone
- CN5 thermostat d’ambiance
Содержание 20114905