12
05/2010
Rieber GmbH & Co KG
5.1.3 Dispose of packaging material
•
Dispose of packaging material in a proper and environmentally compatible manner.
5.1.4 Clean the appliance
•
Clean the appliance thoroughly before using for the first time.
Clean with a damp cloth and rub dry with a clean cloth.
Rinse the accessories.
Please refer to "Cleaning and maintenance" on Page 25ff
5.2 Commissioning / recommissioning
5.2.1 Preconditions
•
The appliance has no defects or visible damage.
•
The appliance has room temperature and is dry.
NOTE
Protective foils or heat-sensitive objects at/in the appliance might damage the appliance during heating.
•
Ensure that there are no protective foils on the appliance.
Mechanical requirements for the installation site must be met.
•
The place of installation must be horizontal. The place of installation must have sufficient load capacity to
carry the appliance.
•
The casters must be secured by parking brakes to prevent accidental running away.
•
A minimum distance to walls must be kept to prevent fingers, clothes, etc. from getting caught when
placing/taking out crockery.
Applicable electrical regulations must be observed.
•
Before commissioning, check the mains voltage and type of current.
Check that these match the specifications on the type plate.
•
The electrical requirements of VDE 0100 ff. as well as the technical
connection requirements of the local power utility must be met.
•
The socket outlet must be easily accessible so that the unit can be disconnected from power supply at any
time.
5.2.2 Applies to all heatable versions of thermoport
®
The heating method is indicated on each appliance – „dry heating“ or with „water vapour“ as well as the water
quantity. Preheat your new thermoport once before first use.
5.2.3 thermoport
®
with controllable cooling
CAUTION
After transporting electrical cooling appliances, allow the cooling liquid to
settle. Otherwise, the appliance may be damaged.
••••
After transport, put the appliance in ist correct position and allow it to rest for at least
one hour before switching it on.