Connecting/Disconnecting 5/8" and 3/4" Drum Machine
Cable Couplings
Keep couplings clean and lubricated. Plunger pin must move freely and fully extend to secure connection.
6
Instructions for Installing AUTOFEED
Loosen the knob on the top bearing housing and slide the
AUTOFEED onto the pigtail. Secure the AUTOFEED by
tightening the T-shaped mounting knobs.
Instructions for Installing Cable
Do not remove bands or staples from cable
shipping carton. Cable is under tension and will whip,
causing injury.
Retrieve end of cable through the center hole of carton and
remove enough cable to connect with drum pigtail. Connect
the male coupling of the cable to the pigtail coupling
(see
Figure 6). Confirm connection is secure. Feed cable into
drum.
K-7500 Drain Cleaning Machine
Figure 4 – Inserting
Handle
Figure 5 – Secure Handles
with Cotter
Pins. Tighten
Two (2) “T”
Shaped Knobs
CAUTION
New style – Plunger pin
Screwdriver required.
Connecting
1. Slide the couplings together. If needed, depress plunger
pin.
2. Confirm connection is secure. (plunger pin fully ex-
tended).
Disconnecting
1. Insert the screwdriver to depress the plunger pin.
2. Push the couplings apart until the male coupling con-
tacts the screwdriver.
3. Remove the screwdriver and push the couplings apart.
1
2
Old style – Rotating pin
Screwdriver required.
Connecting
1. Slide the couplings together.
2. Rotate pin so hash mark is away from end of cable (to-
wards “L” stamped on coupling). Confirm connection is
secure.
Disconnecting
1. Rotate pin so hash mark is towards end of cable (away
from “L” stamped on coupling).
2. Push the couplings apart.
1
3a
3b
2
Hash Mark
Figure 6
www.
.com
1.800.561.8187