RIDGID 1000RSDSSmart Скачать руководство пользователя страница 1

PUMP SPECIFICATIONS

POWER SUPPLY REQUIREMENTS

120 V, 60 Hz

MOTOR 

                           Single Phase, Dielectric Oil Filled

HORSEPOWER 

 1 HP ....................

CIRCUIT REQUIREMENTS

 15 A (minimum)

DIMENSIONS

                             11-1/2 in. high x 9-3/4 in. base

ON LEVEL (FACTORY SET)

Approximately 9.5 in.

OFF LEVEL (FACTORY SET)

Approximately 4.5 in. 

Smart Submersible Sump Pump

Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.

    Installation Manual                                                                                                     1000RSDSSmart

PERFORMANCE GAL/HR

Model

HP

Discharge Head (Lift Distance)

    0 ft         5 ft        10 ft       15 ft         20 ft  

1000RSDSSmart

1

6600

6240

5640

4920

3660

600007-001 B 04/21

© 2021, RIDGID® TOOL COMPANY

www.homedepot.com

CONSTRUCTION

MOTOR HOUSING

Stainless Steel

VOLUTE

                           Cast Iron

IMPELLER

 Glass Reinforced Thermoplastic

SHAFT

 Steel

DISCHARGE

                             1-1/2 in. NPT

CONTROLLER SPECIFICATIONS

SWITCH

Solid State Air Switch

CONNECTIVITY

                           Wi-Fi + BLE

AIR TUBE

 PVC

Содержание 1000RSDSSmart

Страница 1: ...tect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference Installation Manual 1000RSDSSmart PERFORMANCE GAL HR Model HP Discharge Head Lift Distance 0 ft 5 ft 10 ft 15 ft 20 ft 1000RSDSSmart 1 6600 6240 5640 4920 3660 600007 001 B 04 21 2021 RIDGID TOOL COMPANY www...

Страница 2: ...lifié et être conforme au Code électrique national et à tous les codes et règlements locaux applicables NEVER REMOVE THE GROUND PRONG from the plug or bypass the grounding wires NE JAMAIS RETIRER LE CONNECTEUR DE MISE À LA TERRE de la prise ou contourner les fils de mise à la terre MAKE SURE THE POWER SUPPLY HAS A FUSE OR CIRCUIT BREAKER rated to handle the current amps noted on the pump nameplate...

Страница 3: ...e raccordement tombe dans le puisard Si la prise n est pas à portée du cordon d alimentation de la pompe contacter un électricien qualifié pour installer une nouvelle prise CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED MAY RESULT IN MINOR OR MODERATE INJURY MISE EN GARDE LA MENTION MISE EN GARDE INDIQUE UNE SITUATION POTENTIELLEMENT DANGEREUSE QUI SI ELLE N EST PAS ÉVITÉ...

Страница 4: ...enerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment of...

Страница 5: ...ferencia incluidas las interferencias que puedan causar un funcionamiento no deseado del dispositivo DÉCLARATION D INTERFÉRENCE DE LA FCC Cet équipement a été testé et jugé conforme aux limites d un appareil numérique de classe B conformément à la partie 15 des règles de la FCC Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation...

Страница 6: ...y and not freeze 12 Secure the basin cover and gasket to the basin to prevent debris from falling into the basin prevent personal injury and to contain gases and or odors 13 For device activation follow the instructions found on the next page TYPICAL SUMP INSTALLATION 1 This installation must be in accordance with the National Electric Code and all applicable local codes and ordinances 2 Use a bas...

Страница 7: ...ed Then check your discharge pipe for obstructions or leaks that allow water back into the pit 4 Consider replacing your pump soon to stay protected Red 1 There is a critical issue with your pump 1 Replace your pump immediately DIGITAL CONTROLLER BUTTON Function Action to Take Mute Alarm Short press at least 1 second System Test Hold for 5 seconds pump health LED will flash blue and release Reboot...

Страница 8: ...ra and use your camera to scan the QR code located on the front of your device NOTE Camera will automatically scan QR code when brought into view 6 After the app Finds your device a network list of local connections will be displayed Select your network and enter your password credentials Click Send 7 Once connected to Wi Fi your device will be registered 8 The app will now ask for your zip code B...

Страница 9: ...at the end of product life TROUBLESHOOTING CHART FOR PUMP Symptoms Possible Cause s Suggested Remedies Pump will not start or run 1 Water level too low 2 Blown fuse or tripped circuit breaker 3 Low supply voltage 4 Motor 5 Switch 6 Inlet screen clogged 7 Switch obstruction 1 Water must be at the appropriate level to activate switch 2 If blown determine cause and then either replace with proper siz...

Страница 10: ...zed for application 5 Check valve stuck closed or installed backwards 6 Shut off valve closed 1 Contact an electrician 2 Remove debris 3 Replace pump 4 Recheck all sizing calculations to determine proper pump size 5 Remove and examine check valve for proper installation and free operation 6 Open valve ROUTINE SUMP MAINTENANCE The pump should be inspected 3 4 times per year for pump movement or bui...

Страница 11: ...SET WI FI CONNECTION AND REBOOT Use this function to re establish an existing or new connection to your device without losing any personalized settings or data associated with your device NOTE It is highly recommended that a Wi Fi connection reset follow the direction on the app for resetting the Wi Fi connection for your device RESET TO FACTORY SETTINGS AND REBOOT NOTE It is highly recommended th...

Страница 12: ... This Limited Warranty does not cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with RIDGID Pumps written instructions THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES OBLIGATIONS OR AGREEMENTS EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS F...

Отзывы: