39
Skip keys lock
➥
Communication
ON
Prevents
ing of the physical buttons while the RD60xx unit is communicating.
OFF
s the physical controls when communicating.
IF
OFF,
When the RD60xx is communicating via any interface (Interface-UART or
Interface-USB), the unit’s controls are
ed and can only be controlled by the
remote device. (PC, Smartphone App, etc)
IF
ON,
The RD60xx unit can be controlled by the remote device OR the controls on the
unit itself.
SkipExitIVSet
➥
Appearance
ON
Pressing
“
ON/OFF
”
button will NOT exit Voltage or Current adjustments.
OFF
Pressing
“
ON/OFF
”
button will accept and exit Voltage or Current adjustments.
IF
ON
,
Pressing
“
ON/OFF
”
will toggle the output state only. Any in-process Voltage or
Current adjustments are NOT taken into account and the adjustment setting
cursor remains active.
IF
OFF
,
Pressing
“
ON/OFF
”
will toggle the output state AND immediately exit, without
saving, any in-process Voltage or Current setting adjustment.
Standby LED
➥
Power Settings
“
POWER
”
Button Illumination when device turned off (In Standby)
Pulsating
Continually sweeps from OFF to full brightness and back.
0%
No illumination in OFF state.
5% - 100%
Continuous illumination at brightness selected. (5% increments)
All options, except
Pulsating
, allow the RD60xx to go into a power-saving sleep mode.
(Lowering standby power usage)