○ or react per the setting of ‘
’.
● The
Indicator is replaced by a red background white
‘OTP’ Icon.
Notes:
-
Disabled by setting to
0
.
-
Should be set to a higher value than the ambient temperature for proper operation.
-
This setting does NOT affect the RD60xx cooling fan.
(Which will turn on automatically when the internal sensor reaches 40
°C
.)
-
There is a pre-set, 80
°C
, non-changeable OTP for the internal sensor.
-
The external temperature probe CAN be used in conjunction with this setting to monitor
the
temperature for overheating, if the user wishes to mount the
sensor as such.
-
The ‘OTP (EXT)’ setting is semi-independent from the ‘
’ setting used for
battery charging.
-
‘OTP (EXT)’ will trigger
during all modes of operation.
-
‘
’ only triggers
during charging operations.
-
IF
‘
’ is enabled:
This value, ‘OTP (EXT)’, should be set to a higher value than the ‘
’ to ensure proper operation during charging cycles.
OVP
(Over Voltage Protection)
Can only be enabled by Panel buttons
(
“
SHIFT
” + “
V-SET
”)
IF
the Voltage reaches, or exceeds, the set value:
● Unit will enter
● The output will immediately turn OFF.
○ (versus the RD60xx unit adjusting its output to maintain the ‘V-Set’ value.)
● The
“
ON/OFF
”
Button will turn off its illumination,
○ or react per the setting of ‘
’.
● The Voltage measurement value will be changed to the ‘OVP’ display colour.
○ See
‘Colours Group’ Detailed Explanation
● The
Indicator is replaced by a red background white
‘OVP’ Icon.
Notes:
-
Disabled by setting to
0
.
-
When Setting,
“
SHIFT
”
button will be illuminated to visually distinguish an ‘OVP’ input
from a ‘V-SET’ input..