6.3.7
Acid dosing
Controls / Water / Substrate / Irrigation, EC and pH / Irrigation valve
groups / Recipes
tab: pH dosing
Use the
pH dosing
tab to base the acid dosage on the pH setpoint.
6.3.8
Filters
Controls / Water / Substrate / Installation / Filter sets
Use filter sets to manage the settings for the filters. These includes the following
standard settings:
Duration of filter set flush step
Wait time after flushing filter set
Interrupt irrigation cycle to flush filter set
System pump used to flush filter set
Settings, such as 'Maximum operating time for start filter set flushing', only appear if
you have selected the corresponding option(s) during configuration in CX Assistant
(see "Software configuration" on page 38).
Filter flushing can also be started manually. For example, this can be done
based on the pressure difference before and after the filter (which can be read
from the pressure gauges).
6.3.9
Start conditions
Controls / Water / Substrate / Starts
The start conditions for an irrigation cycle can be set for each valve group (and
period). There are various types of starts:
Manual valve start
Use manual valve start to specify in which periods you can start irrigation
manually.
Manual group start
Use manual group start to start irrigation manually. Using this control you can
also stop, pause or restart irrigation manually.
Time start
Use time start to start irrigation at specific times (daily or weekly). You can
also use time start to set alternative time starts and cyclical starts.
Alternative start: use an alternative start to start irrigation once at a specified
time.
Cyclical start: use a cyclical start to start the irrigation at regular intervals.
Pause start
Use pause start if an irrigation group may not go without irrigation for a
specified period of time, regardless of the conditions.
Radiation sum start
Use radiation sum start to start irrigation when a specified radiation sum is
reached.
FertiMiX