PUMP PRECAUTIONS
To prevent damage to the system pump, the FertiMiX will stop and generate an
alarm message if:
The pump starts to overheat.
As an option, the system pump can be fitted with a temperature sensor. This
sensor produces an alarm when the water around the pump gets too hot.
Consult the manual for the system pump to regulate the direction and
bleed air from the pump.
5.5.2
Water supply and pressure
You need to adjust the water supply and set the water pressure to the venturis.
Adjust the water supply
Turn the knob on the valve (1) to adjust
to the water supply.
Set the water pressure to the
venturi
Turn the adjustment screw (1) until the
pressure gauge (2) after the filter
displays 2.2 bars. This is the pressure on
the venturis.
5.6
Using the dosing channels for the first time
Ridder Growing Solutions advises you to test the FertiMiX first with water,
before using fertilizers and/or acid.
FertiMiX
46