Check the sensor.
Contact your installer.
5.11
Error
Watchdog switched off, remove watchdog jumper
Alarm monitoring in the process computer is disabled.
Contact your installer.
Your installer can remove the watchdog jumper for you, so that alarm
monitoring will be enabled again.
5.12
I/O modules
Module type not correct
The type of module found does not match the type of module that was expected.
The module has overloaded.
The electric current protection of the outputs has been activated.
Reset the module. Max. current for each output is 500 mA, max. current for
each module side is 2 A.
Module contact lost
The connection with the I/O module has been lost.
Check whether the module is present and receiving power.
Check the I/O bus cable.
Module contact restored
The connection with the I/O module has been restored, or a malfunction of the I/O
module has been resolved.
Module unreliable
The module failed to initialize while the computer was starting up.
Switch the computer off and back on.
I/O module fault
A malfunction with one or more of the modules has occurred.
Check the system.
Aqua CX300
91