Repetition 0 & 10
The number of times a start will still be repeated (the number of times executed
minus the number of times set).
Contact start level 0 & 100
The level that must be measured by the sensor for a contact start to be executed.
Main pause time
The number of minutes during which the valve group, after it has stopped, may not
start again automatically. The start is delayed until the main pause time has elapsed.
This setting prevents a new start from being executed, just after the valve group has
completed an irrigation cycle.
A manual start is always performed immediately.
Influence on irrigation volume 0 - 1000 Liters
The volume by which an irrigation cycle has been increased or reduced (in the event
of a negative value) as a result of the measured contact value.
Influence on irrigation time 0 - 3600 sec.
The duration by which an irrigation cycle has been lengthened or shortened (in the
event of negative value) as result of the influence of the measured contact value.
Manual start
Yes: A manual start has been executed for the valve group. However, the group has
not yet been activated, because another group is still active.
Number of starts 0 - 100
The number of starts that have been executed since the 'Registration reset time'.
4.3
Registration per valve group
Valve group status
Volume of last irrig. cycle
Duration of last irrig. cycle
Time of last start
Date of last start
Reason for start
Number of starts
Av. monitor EC/24hr-period
Av. pre-meas. EC/24hr-period
Av. pre-blend. EC/24hr-period
Av. control pH/24hr-period
Av. monitor pH/24hr-period
Path: Display summaries>Registrations per valve group