No
Contact your service representative.
• The top sheet of each offset bundle of delivered sheets may protrude above the rest of the bundle
by about 7 mm.
Stacker shift tray
Paper feed direction
CEZ605
The Machine Wrongly Detects That the Tray Is Full
Cause:
Depending on the paper size, the machine may detect that the shift tray has reached the maximum
number of sheets that can be stacked on it.
This may occur if paper with a width of 191-261 mm (7.6 - 10.4 inches) is being used.
Solution:
< Paper with a width of 191–261 mm (7.6 - 10.4 inches) is being used >
1.
Load the sheets the other way up.
2.
Print the image. Has the problem been resolved?
Yes
Finished!
No
Go to the next step.
To follow the steps below, attach the decurler unit.
3.
In the [Machine: Paper Feed/ Output] group of the [Adjustment Settings for Operators]
menu, set 0304: [Correct Output Paper Curl] to " Curl Correction Level: Off".
9. Post-Processing Option Troubleshooting