2.Replacement and Adjustment
119
Notes on Harness Routing During Reattachment
If you have released the harness from the clamp when disconnecting a connector, be sure to route and
secure the harness in its original position.
Be especially careful to correctly route and secure the harness connected to the following parts/units as
described below.
If the harness is not routed or secured correctly, it may interfere with the operation of some units or may
become damaged or broken.
Booklet Finisher SR3270: Harness [A] from Door Switch
Secure the harness with 3 clamps [B] as shown. (Route the harness so that each of its 2 cable ties [C]
is below the nearest clamp.)
Содержание SR3260
Страница 2: ......
Страница 6: ......
Страница 16: ...1 Detailed Descriptions 10 658 x 665 x 960 mm 25 9 x 24 5 x 37 8 inches Weight Approx 34 kg 75 0 lb...
Страница 45: ...1 Detailed Descriptions 39 Stapler movement process The movement differs between Single and Double stapling...
Страница 58: ...1 Detailed Descriptions 52...
Страница 92: ...2 Replacement and Adjustment 86 4 Remove the Feedout Pawl Motor STM4 A from the bracket...
Страница 103: ...2 Replacement and Adjustment 97 2 Remove the Paper guide HP sensor S37 A...
Страница 106: ...2 Replacement and Adjustment 100 8 Remove the guide plate A 9 Remove the stapler cartridge A 10 Remove the cover A 2...
Страница 122: ...2 Replacement and Adjustment 116 3 Remove the Booklet Transport Lower Pressure Release HP Sensor S5 A...
Страница 128: ...2 Replacement and Adjustment 122 Secure the harness so that the relay connector A is above the clamp B...