Service Call
M0C3/M0C4/M0C5/M0C6/M0C7
6-4
SM
No.
Type
Error Name/Error Condition/Major Cause/Solution
SC220 D
Beam synchronization error
The laser synchronization detection signal for the LD is not output within 0.4 sec.
after the laser unit has turned on.
•
Disconnected cable from the laser synchronization detector defective
connection
•
Defective laser synchronization detector/ main board
•
The beam does not enter the laser synchronization detector
1. Turn the power OFF and ON.
2. Replace the polygon mirror motor/ laser unit.
3. Replace the interface harness of the laser unit.
4. Replace the main board.
No.
Type
Error Name/Error Condition/Major Cause/Solution
SC268 D
Laser unit thermistor error
•
The laser unit thermistor detected a temperature lower than -30°C for more
than 4 sec.
•
The laser unit thermistor detected a temperature higher than 105°C for more
than 1 sec.
•
Thermistor disconnected (causes an extremely low temperature reading)
•
Defective harness
•
Defective main board
1. Turn the power OFF and ON.
2. Replace the laser unit thermistor.
Содержание SP 330SFN
Страница 1: ...M0C3 M0C4 M0C5 M0C6 M0C7 SERVICE MANUAL...
Страница 24: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None...
Страница 26: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None...
Страница 41: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None...
Страница 46: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None...
Страница 208: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None...
Страница 242: ...DETAILED DESCRIPTIONS REVISION HISTORY Page Date Added Updated New None...
Страница 292: ...M0C3 M0C4 M0C5 M0C6 M0C7 SERVICE MANUAL APPENDICES...
Страница 294: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None...
Страница 309: ...SETTING FOR PAAS ONLY FOR CHINA REVISION HISTORY Page Date Added Updated New None...
Страница 321: ...M534 PAPER FEED UNIT PB1130 REVISION HISTORY Page Date Added Updated New None...