![Ricoh SP 230SFNw Скачать руководство пользователя страница 248](http://html1.mh-extra.com/html/ricoh/sp-230sfnw/sp-230sfnw_service-manual_1455349248.webp)
5-43
Confidential
1.3.26 Reset irregular power supply detection counter of low-voltage power
supply PCB (Function code 88)
<Function>
This function is used to reset the corresponding counter after the low-voltage power supply
PCB ASSY is replaced. The number of times the part has been replaced is increased by one.
<Operating Procedure>
(1) Press the [8] twice in the initial state of maintenance mode. For models without keypad,
press the [
▲
] or [
▼
] to display “MAINTENANCE 88” on the LCD and press the [OK].
“Reset- LVPS” is displayed on the LCD.
(2) Press the [Start] or [Mono Start].
(3) “Reset-LVPS OK?” is displayed on the LCD. Press the [Start] or [Mono Start] to reset the
number of times that irregular power supply errors occurred and “Reset-LVPS” is
displayed on the LCD.
(4) Press the [X] or [Stop], and the machine returns to the initial state of maintenance mode.
1.3.27 Quit maintenance mode (Function code 99)
<Function>
This function is used to quit the maintenance mode, restart the machine, and return it to the
ready state. Also forcefully close the fuser unit error.
<Operating Procedure>
(1) Press the [9] twice in the initial state of maintenance mode. For models without keypad,
press the [
▲
] or [
▼
] to display “MAINTENANCE 99” on the LCD and press the [OK]. The
machine quits the maintenance mode and returns to the ready state.
Содержание SP 230SFNw
Страница 29: ...2 8 Confidential 2 2 2 Scanner part Fig 2 4 Document feed path...
Страница 120: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton...
Страница 177: ...3 59 Confidential 8 21 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 51 Hook Filter Air duct...
Страница 226: ...5 21 Confidential Print adjustment test pattern Fig 5 5...
Страница 234: ...5 29 Confidential Print pattern Fig 5 9 W 100 K 1 K 100 Total Lattice K 5...
Страница 239: ...5 34 Confidential Test pattern Fig 5 12...