2-92
Confidential
Partially shaded
Fully tinged
<User Check>
• Clean the scanner glass.
Step
Cause
Remedy
1
Dirt inside of scanner glass
Clean the inside of scanner glass.
2
Deformed document sponge
Replace the document scanner unit.
<User Check>
• Clean the scanner glass or scanner glass strip.
Step
Cause
Remedy
1
Incorrect white level
correction data
Execute “Acquire white level data
2
CIS unit failure
Replace the CIS unit.
3
Main PCB failure
Replace the main PCB ASSY.