2-90
Confidential
Completely blank
All black
<User Check>
• Check that the document is not reversed.
Step
Cause
Remedy
1
Incorrect white level
correction data
Execute “Acquire white level data
2
CIS flat cable failure
Replace the CIS flat cable.
3
CIS unit failure
Replace the CIS unit.
4
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Install all the latest firmwares.
Step
Cause
Remedy
1
Incorrect white level
correction data
Execute “Acquire white level data
2
CIS flat cable failure
Replace the CIS flat cable.
3
CIS unit failure
Replace the CIS unit.
4
Main PCB failure
Replace the main PCB ASSY.