Adjusting the UV Lamp Position
Adjusting the UV Lamp Position
When printing using clear ink, adjust the UV lamp position as described below.
• When not using clear ink, be sure to set both the left and right UV lamps to the "0 mm" position.
• When using clear ink, do not perform reverse direction printing.
1.
Open left UV lamp cover.
ECD223
2.
Turn the UV lamp securing screw counterclockwise to loosen it.
0
1
2
3
4
5
6
0
1
2
3
4
5
6
ECD240
3.
Slide the UV lamp to align the arrow with 20 mm (graduation "2").
If not using clear ink align the arrow with 0 mm (graduation "0").