2. To avoid possible accumulation of ozone in the work area, locate the machine in a large well
ventilated room that has an air turnover rate of more than 30m
3
/hr/person.
3. Toner and developer are non-toxic, but if you get either of them in your eyes by accident, it may
cause temporary eye discomfort. Try to remove with eye drops or flush with water as first aid. If
unsuccessful, get medical attention.
Observance of Electrical Safety Standards
1. The machine and its peripherals must be installed and maintained by a customer service
representative who has completed the training course on those models.
2. The NVRAM on the system control board has a lithium battery which can explode if replaced
incorrectly. Replace the NVRAM only with an identical one. The manufacturer recommends
replacing the entire NVRAM. Do not recharge or burn this battery. Used NVRAM must be handled
in accordance with local regulations.
Safety and Ecological Notes for Disposal
1. Never incinerate toner bottles or used toner. Toner dust may ignite suddenly when exposed to an
open flame.
2. Dispose of used toner, developer, and organic photoconductors in accordance with local
regulations. (These are non-toxic supplies.)
3. Dispose of replaced parts in accordance with local regulations.
4. When keeping used lithium batteries in order to dispose of them later, do not put more than 100
batteries per sealed box. Storing larger numbers or not sealing them apart may lead to chemical
reactions and heat build-up.
• The danger of explosion exists if a battery of this type is incorrectly replaced.
• Replace only with the same or an equivalent type recommended by the manufacturer. Discard
used batteries in accordance with the manufacturer's instructions.
Laser Safety
The Center for Devices and Radiological Health (CDRH) prohibits the repair of laser-based optical units
in the field. The optical housing unit can only be repaired in a factory or at a location with the requisite
equipment. The laser subsystem is replaceable in the field by a qualified Customer Engineer. The laser
chassis is not repairable in the field. Customer engineers are therefore directed to return all chassis and
laser subsystems to the factory or service depot when replacement of the optical subsystem is required.
8
Содержание M0AE-17
Страница 1: ...Model Rev P1 MF1 Machine Codes SFP M290 M0AF MFP M291 M0AE Field Service Manual January 2016 ...
Страница 2: ......
Страница 18: ...16 ...
Страница 24: ...1 Product Information 22 ...
Страница 26: ...2 Installation and Preventive Maintenance 24 ...
Страница 49: ...2 Remove the HVP A x4 x1 Electrical Components 47 ...
Страница 56: ...3 Replacement and Adjustment 54 ...
Страница 79: ...6 Energy Saving Energy Save Energy Saving Modes 77 ...
Страница 80: ...MEMO 78 ...
Страница 81: ...MEMO 79 ...
Страница 82: ...MEMO 80 EN ...