TROUBLESHOOTING FLOW CHART
4-15
Trouble-
shooting
4.5.10 HORIZONTAL BAND
Black
band is far about 10
mm from white
band?
Black band?
Does
it appear at every
56.1 mm at specific
place?
The black band has
regular interval?
Problem of internal
contacts in OPC
→
Replace AIO
YES
YES
The OPC is damaged
under the direct sunlight
for around 5 minutes
→
If the same problem
persists in 10 hours,
replace the AIO
NO
NO
NO
75.4 mm interval?
This occurs when no
Hsync/ at LSU
→
Replace the LSU
Heat roller is ruined
→
Replace the Fusing
unit
The OPC is damaged due
to the irregular transfer
voltage of HVPS
→
Repair/replace HVPS
→
If the same problem
persists, replace the
AIO
YES
YES
NO
Problems of terminal
contact, transfer voltage
supplying, and transfer
roller's due to the charge
roller is ruined (37.7 mm)
→
Repair/replace the
HVPS, AIO
NO
YES
H911T920.WMF