Ricoh LANIER MP 301SP Скачать руководство пользователя страница 1

 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

D127/D128 

SERVICE MANUAL 

 

 
 
 
 
 
 

Содержание LANIER MP 301SP

Страница 1: ...D127 D128 SERVICE MANUAL ...

Страница 2: ...SION OF RICOH AMERICAS CORPORATION All product names domain names or product illustrations including desktop images used in this document are trademarks registered trademarks or the property of their respective companies They are used throughout this book in an informational or editorial fashion only and for the benefit of such companies No such use or the use of any trade name or web site is inte...

Страница 3: ...ation Users of this manual should be either service trained or certified by successfully completing a Ricoh Technical Training Program Untrained and uncertified users utilizing information contained in this service manual to repair or modify Ricoh equipment risk personal injury damage to property or loss of warranty protection Ricoh Americas Corporation WARNING ...

Страница 4: ...LEGEND PRODUCT CODE COMPANY LANIER RICOH SAVIN D127 MP 301SP Aficio MP 301SP MP 301SP D128 MP 301SPF Aficio MP 301SPF MP 301SPF DOCUMENTATION HISTORY REV NO DATE COMMENTS 06 2012 Original Printing ...

Страница 5: ...ponents 2 1 7 ARDF 1 8 1 3 3 PAPER PATH 1 9 1 3 4 DRIVE LAYOUT 1 10 Mainframe 1 10 ARDF 1 11 1 4 GUIDANCE FOR THOSE WHO ARE FAMILIAR WITH PREDECESSOR PRODUCTS 1 12 2 INSTALLATION 2 1 2 1 INSTALLATION CAUTIONS 2 1 2 2 INSTALLATION REQUIREMENTS 2 2 2 2 1 ENVIRONMENT 2 2 2 2 2 MACHINE LEVEL 2 2 2 2 3 MINIMUM OPERATIONAL SPACE REQUIREMENTS 2 3 2 2 4 POWER REQUIREMENTS 2 4 2 3 COPIER 2 5 2 3 1 ACCESSOR...

Страница 6: ... 5 5 JOINT BRACKET JOINT THE UPPER AND THE LOWER PTU 2 28 2 6 CONTROLLER OPTIONS 2 29 2 6 1 OVERVIEW 2 29 2 6 2 WIRELESS LAN IEEE 802 11A G INSTALLATION 2 30 Accessories 2 30 Installation Procedure 2 30 SP Mode Settings for IEEE 802 11a g Wireless LAN 2 31 2 6 3 IEEE 1284 INSTALLATION 2 31 Accessories 2 31 Installation Procedure 2 32 2 6 4 VM CARD TYPE S D656 2 33 Accessories 2 33 Installation 2 3...

Страница 7: ...RATION PANEL 4 3 4 3 1 REAR COVER 4 3 4 3 2 COPY TRAY 4 3 4 3 3 OPERATION PANEL 4 4 4 3 4 RIGHT DOOR 4 5 4 3 5 BYPASS TRAY 4 5 4 3 6 PLATEN COVER AND ARDF SENSOR 4 6 4 4 SCANNER UNIT 4 7 4 4 1 SCANNER COVER AND EXPOSURE GLASS 4 7 4 4 2 LED UNIT 4 8 4 4 3 SCANNER MOTOR 4 9 4 4 4 SCANNER HP SENSOR 4 9 4 5 FUSING 4 10 4 5 1 FUSING UNIT 4 10 4 5 2 EXIT SENSOR 4 10 4 5 3 HOT ROLLER STRIPPER PAWLS 4 11 ...

Страница 8: ...OLLER 4 29 4 9 3 DISCHARGE PLATE 4 31 4 10 BICU AND CONTROLLER BOARD 4 32 4 10 1 BICU 4 32 Preparation 4 32 Procedure 4 32 4 10 2 CONTROLLER BOARD 4 33 Preparation 4 33 Procedure 4 33 When installing a new controller board 4 35 When replacing the NVRAM on the controller board 4 36 4 11 OTHER REPLACEMENTS 4 37 4 11 1 DUPLEX MOTOR 4 37 4 11 2 HIGH VOLTAGE POWER SUPPLY BOARD 4 38 4 11 3 PSU 4 39 4 11...

Страница 9: ...egistration 4 57 Adjusting Blank Margin 4 59 Adjusting Main Scan Magnification 4 60 4 14 2 SCANNING 4 60 Adjusting Registration 4 60 Adjusting Magnification 4 61 4 14 3 DF IMAGE ADJUSTMENT 4 62 5 SYSTEM MAINTENANCE REFERENCE 5 1 5 1 SERVICE PROGRAM 5 1 5 1 1 SP TABLES 5 1 5 1 2 USING SP AND SSP MODES 5 1 Starting SP Mode 5 1 Selecting Programs 5 2 Specifying Values 5 2 Activating Copy Mode 5 2 Qui...

Страница 10: ...5 13 5 2 7 SMC PRINT SP5 990 5 14 5 2 8 ID SENSOR ERROR ANALYSIS SP2 220 5 14 5 3 FAX SERVICE TABLES 5 15 6 TROUBLESHOOTING 6 1 6 1 SC TABLES 6 1 6 1 1 SUMMARY 6 1 6 1 2 ENGINE SC CODE DESCRIPTIONS 6 2 6 1 3 SC CODE DESCRIPTIONS 6 15 SC6xx 6 15 SC8xx 6 20 SC9xx 6 39 6 2 ELECTRICAL COMPONENT DEFECTS 6 42 6 2 1 SENSOR SWITCH 6 42 6 2 2 BLOWN FUSE CONDITIONS 6 44 6 3 CARD SAVE FUNCTION 6 45 6 3 1 OVE...

Страница 11: ...128 Recommendation 7 2 7 1 2 ENERGY SAVE EFFECTIVENESS 7 2 7 2 PAPER SAVE 7 4 7 2 1 EFFECTIVENESS OF DUPLEX COMBINE FUNCTION 7 4 1 Duplex 7 4 2 Combine mode 7 4 3 Duplex Combine 7 5 Recommendation 7 5 D127 D128 7 6 ...

Страница 12: ......

Страница 13: ...ectrical components until job execution has started The copier will start making copies as soon as warm up or initialization is finished 6 The inside and the metal parts of the fusing unit become extremely hot while the copier is operating Be careful to avoid touching those components with your bare hands Health Safety Conditions Toner and developer are nontoxic but getting either of these into yo...

Страница 14: ...d up Laser Safety The Center for Devices and Radiological Health CDRH prohibits the repair of laser based optical units in the field The optical housing unit can only be repaired in a factory or at a location with the requisite equipment The laser subsystem is replaceable in the field by a qualified Customer Engineer The laser chassis is not repairable in the field Customer engineers are therefore...

Страница 15: ... Laser beams can seriously damage your eyes CAUTION MARKING Symbols and Abbreviations This manual uses several symbols and abbreviations The meaning of those symbols and abbreviations is as follows See or Refer to Clip ring E ring Screw Connector Clamp SEF Short Edge Feed LEF Long Edge Feed Core Technology manual ...

Страница 16: ... special information Failure to obey warning information could result in serious injury or death Obey these guidelines to ensure safe operation and prevent minor injuries This information provides tips and advice about how to best service the machine ...

Страница 17: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...

Страница 18: ......

Страница 19: ...Specifications SM 1 1 D127 D128 Product Information 1 PRODUCT INFORMATION 1 1 SPECIFICATIONS See Appendices for the following information General Specifications Supported Paper Sizes ...

Страница 20: ... Remarks 1 Copier A D127 D128 2 ARDF C D606 Standard expect for EU Option for EU 3 Platen Cover D607 Standard for EU 4 Fax Unit D D655 Standard only for D128 Option only for D127 Optional Components Machine Code Remarks 5 500 sheet Paper Feed Unit B D661 Two units can be added at maximum 6 Handset F D645 NA only ...

Страница 21: ... SD card for the Printer Scanner Unit Standard FAX Option D655 F FAX Connection Unit D660 B Browser Unit D656 B VM Card D656 C In SD slot 2 lower Net Ware D659 C SD Card for Net Ware printing Type 1 IEEE 1284 B679 D One from the two Gigabit Ethernet Board G874 D HDD D659 E Optional HDD with Interface board Merge the Security Card into the Printer Scanner SD card ...

Страница 22: ...D Unit 18 Bypass Paper End Sensor 3 Platen Cover Sensor 19 Bypass Friction Pad 4 Exit Roller 20 Registration Roller 5 Hot Roller 21 Registration Sensor 6 Exit Sensor 22 Main Friction Pad 7 Pressure Roller 23 Paper Feed Roller 8 Scanner Motor 24 Paper End Sensor 9 Cleaning Web Roller 25 TD Toner Density Sensor ...

Страница 23: ... Roller 15 ID Image Density Sensor 31 Toner Supply Bottle 16 Bypass Paper Feed Roller 32 Scanner HP Sensor ARDF 1 Pull out Roller 10 Registration Roller 2 Feed Roller 11 Registration Sensor 3 Friction Pad 12 Scanner Guide 4 Paper Stopper 13 ARDF drive motor 5 Pick up Roller 14 Exit Roller 6 Original Set Feeler 15 Junction Gate 7 Original Set Sensor 16 Inverter Roller 8 Upper Cover Sensor 17 Platen...

Страница 24: ...ner HP Sensor 11 Registration Sensor 3 Platen Cover Sensor 12 Paper End Sensor 4 Scanner Motor 13 Toner Density Sensor 5 High Voltage Power Supply Board 14 Bypass Paper End Sensor 6 Operation Panel Board 15 Right Door Safety Switch 7 Polygon Mirror Motor 16 Front Door Safety Switch 8 LD Unit 17 Quenching Lamp 9 Exit Sensor ...

Страница 25: ...28 Product Information Electrical Components 2 1 Duplex Motor 7 Paper Feed Clutch 2 Exhaust Fan 8 Toner Supply Motor 3 PSU 9 Bypass Feed Clutch 4 Controller Board 10 Registration Clutch 5 BICU 11 Fusing Solenoid 6 Main Motor ...

Страница 26: ...Overview D127 D128 1 8 SM ARDF 1 Registration Sensor 5 Upper Cover Sensor 2 ARDF Drive Motor 6 Junction Gate Solenoid 3 Pick up Solenoid 7 ARDF Relay Board 4 Original Set Sensor ...

Страница 27: ...gistration Sensor Document Feeder 2 Original Set Sensor Document Feeder 3 Upper Cover Sensor Document Feeder 4 Exit Sensor 5 Paper Path Sensor 6 Registration Sensor 7 By pass Paper End Sensor 8 Paper Feed Sensor Optional Tray 9 Paper End Sensor Optional Tray 10 Paper End Sensor ...

Страница 28: ...T Mainframe 1 Scanner Motor 7 Bypass Feed Clutch 2 Duplex motor 8 Registration Clutch 3 Exit Roller 9 Developer Driver Gear 4 Toner Supply Motor 10 Drum Drive Gear 5 Main Motor 11 One way Gear Duplex Unit 6 Paper Feed Clutch 12 Fusing Drive Gear ...

Страница 29: ...nformation ARDF 1 DF Feed Clutch 2 Feed Roller 3 Pick up Roller 4 Inverter Roller 5 DF Feed Motor 6 Registration Roller 7 Pull out Roller 8 Exit Roller DF Feed Motor 5 Drives the feed pull out pick up and registration and inverter rollers ...

Страница 30: ...tion and Data Overwrite Security Unit Standard Standard only for D115 Copying Speed 30cpm Memory copy 30cpm ADF 1 to 1 20cpm Memory copy 16cpm ADF 1 to 1 The following parts are unique for D127 D128 When replacing the following parts use the parts specified for each model DO NOT mix up the following parts for D115 D116 and D127 D128 Otherwise both of the machine operation and output quality are no...

Страница 31: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...

Страница 32: ......

Страница 33: ...an optional unit do the following Print out all messages stored in the memory all user programmed items and a system parameter list If there is a printer option on the machine print out all data in the printer buffer Turn off the main switch and disconnect the power cord the telephone line and the network cable ...

Страница 34: ...n Ambient Dust Less than 0 1 mg m3 Do not install the machine where it will be exposed to direct sunlight or to direct airflow from a fan air conditioner air cleaner etc Do not install the machine where it will be exposed to corrosive gas Place the machine on a firm and level base Do not install the machine where it may be subjected to strong vibration Do not install the machine at any location ov...

Страница 35: ...mm 3 9 D Right 100 mm 3 9 E Depth 450 mm 17 7 F Width 476 mm 19 1 The 750 mm front space indicated above is sufficient to allow the paper tray to be pulled out Additional space is required to allow an operator to stand at the front of the machine Actual minimum space requirement for left rear and right sides is 10mm 0 4 each but note that this will not allow room for opening of the bypass tray rig...

Страница 36: ...cessible After completing installation make sure the plug fits firmly into the outlet Avoid multiple connections to the same power outlet Be sure to ground the machine Input voltage North America 120 127 V 60 Hz 15 A Europe 220 240 V 50 60 Hz 10 A Image quality guaranteed at rated voltage 10 Operation guaranteed at rated voltage 15 ...

Страница 37: ...et Bracket 17 1 Modular Cable 17 1 EMC Caution Sheet 27 1 EULA Sheet 27 1 Caution Sheet 27 1 Operation Panel Key Name Sign 17 21 27 29 1 PFU Size And Drawer Num Decal 17 21 27 29 1 FAX Masking Decal D12727 D12729 1 Printer Scanner Accessories 17 21 27 29 1 set Power Supply Cord 17 21 27 29 1 Installation Procedure Book 17 27 29 1 Quick Guide 17 29 1 Machine Num Decal 17 21 27 29 1 Under Communicat...

Страница 38: ...g A and A3 sheet of paper B on the exposure glass 3 Fold the SMC and put it in the back of the front door Power supply cord is attached on the back of the main machine 4 Open the front door D 5 Lift lever E press in on latch F and pull the bottle holder G out You do not need to pull it completely out of the machine 6 Take a new bottle of toner and shake it several times ...

Страница 39: ... turn on the main power switch the copier sets the bottle in place 9 Push the bottle holder back into the machine 10 Press the latch J down to lock the holder 11 Remove the tapes K 12 Remove the padding L 13 Pull each tabbed strip M out of the PCU with one hand supporting the PCU with the other Do not pull both strips at the same time as this could damage the PCU 14 Close the front door ...

Страница 40: ... the paper 17 Adjust the side fences If you load paper shorter than A4 set the end fence in the correct position 18 Push the tray back into the copier 19 Attach the appropriate tray number decal and paper size decal to the paper tray N 20 Install optional units if any 21 Attach the ferrite core O to the end of the network cable P when connecting the cable ...

Страница 41: ...lect SP5 801 001 and execute the initialization 3 Exit the SP mode and then start the UP mode 4 Select the Remote Service User Tool System Settings Administrator Tools Extended Security Remote Service and select Do not Prohibit 5 Exit the UP mode and then start the SP mode 6 Select SP5 907 001 and specify the Plug Play 7 Select SP5 302 002 and specify the time zone 8 Select SP5 307 001 003 and 004...

Страница 42: ...n the main power switch off on to clear the error display If another error occurs after initialization this can be a functional problem 1 Select fax SP1 101 016 and specify the country code 2 Select fax SP3 101 001 and specify the service station 2 3 2 OPTIONAL HANDSET Accessory Check Check that you have the components and accessories No Description Q ty 1 Handset 1 2 Handset cradle 1 3 Screws 2 4...

Страница 43: ...ith a screw driver You should detach the tray cover and make holes on it Or you might damage the PSU 2 Attach the handset bracket B to the side of the tray cover x 2 3 Remove the label from the handset cradle C 4 Attach the cradle C to the handset bracket x 2 5 Reattach the label 6 Set the handset on the cradle 7 Connect the core attached handset cable to the TEL jack ...

Страница 44: ...on 1 2 4 2 INSTALLATION PROCEDURE 1 Turn off the main switch of the copier and unplug the power cord before you start the installation procedure 2 You need two or more persons to lift the copier The copier is highly unstable when lifted by one person and may cause human injury or property damage 3 Do not lift the copier with the paper feed unit installed The handle and grips may be damaged 1 Remov...

Страница 45: ...Paper Tray Unit D661 SM 2 13 D127 D128 Installation 2 Pull the paper tray part way out of the unit remove the tape and cardboard A and push the tray back in 3 Set the copier onto the paper tray unit ...

Страница 46: ...e the paper tray s from the paper tray unit s 5 Load paper into the paper tray s Adjust the side and end fences as necessary If loading 81 2 x 14 paper remove the end fence and set it into the special compartment 6 Set the paper tray s back into the paper tray unit s 7 Stick on the appropriate tray number decal s and paper size decal s at the locations indicated in the illustration ...

Страница 47: ... installed at a maximum The operation system doesn t work when more than three of the paper tray units are installed 2 5 1 ACCESSORY CHECK Confirm that you have the accessories listed below Description Q ty 1 Heater fastening screw 2 2 Grounding wire and Harness cover fastening screw 7 3 Washer 7 4 Spring washer 7 5 Joint bracket fastening screw 8 6 Clamp Large 2 7 Clamp Mid 5 8 Clamp Small 2 9 Ed...

Страница 48: ... bracket Front 4 11 Joint bracket Rear 2 12 Heater Harness Long 1 13 Heater Harness Mid 1 14 Heater Harness short 1 15 Grounding wire Long 1 16 Grounding wire Short 1 17 Harness cover 1 18 Guard 1 19 Heater bracket NA Blue EU Red 1 20 High temperature caution decal 1 ...

Страница 49: ...ve the paper tray unit from the copier if it is already installed 2 Remove the rear cover 1 from the paper tray unit x 2 Right screw on the picture is a shoulder screw 3 Fasten the heater 2 x 2 4 Put the clamps Small 3 in the holes 5 Joint the connector 4 to the heater harness Short 5 6 Pass the heater harness Short 5 through the hole 6 7 Attach the heater harness Short through the clamps as shown...

Страница 50: ...Paper Tray Unit Heater D127 D128 2 18 SM 8 Attach the harness cover 7 x 2 Washer x 2 Spring Washer x 2 9 Remove the rear cover 8 x 5 and the copy tray 9 x 1 10 Remove the controller box 10 x 2 x 6 ...

Страница 51: ... the connector 13 on the board 13 Attach the clamp Large 14 14 Lead the heater harness Long 12 through the clamp Large 14 toward inner side of the copier as shown 15 Attach the clamp Large 15 16 Pass the heater harness through the hole 16 to the rear of the copier 17 Attach the grounding wire Long 17 x 1 Washer x1 Spring washer x1 ...

Страница 52: ...sertion easy 21 Pass the support bracket between the copier and the heater harness Long on keeping the end of the heater harness Long in the hole To do step 21 easily be sure not to pass the heater harness Long completely thorough the hole 19 at the step of 20 22 Attach the edge saddle 20 to the support bracket 23 Attach the heater harness Long and the grounding wire Long through the edge saddle a...

Страница 53: ... Be sure to make the bind attached on the heater harness upper than the clamp Mid 22 24 31 Remove the drawer from the paper tray unit 32 Attach the caution decal 25 in the bottom of the paper tray unit 33 Reassemble the copier 34 Plug in the power cord and check the operation 2 5 3 INSTALLATION PROCEDURE FOR TWO OF PTU INSTALLED MACHINE Unplug the main machine s power cord before starting the foll...

Страница 54: ... a shoulder screw 3 Attach the heater 2 to the lower paper tray unit x 2 4 Put the clamps Small 3 in the holes 5 Joint the connector 4 to the heater harness Mid 5 6 Pass the heater harness Mid 5 through the hole 6 7 Attach the heater harness Mid through the clamps as shown 8 Attach the harness cover 7 x 2 Washer x 2 Spring Washer x 2 ...

Страница 55: ...SM 2 23 D127 D128 Installation 9 Attach the guard 8 to the top face of the upper paper tray unit x 1 Washer x 1 Spring Washer x 1 10 Remove the rear cover 9 x 5 and the copy tray 10 x 1 11 Remove the controller box 11 x 2 x 6 ...

Страница 56: ...nnector 14 on the board 14 Attach the clamp Large 15 15 Lead the heater harness Long 13 through the clamp Large 15 toward inner side of the copier as shown 16 Attach the clamp Large 16 17 Pass the heater harness through the hole 17 to the rear of the copier 18 Attach the grounding wire Long 18 x 1 Washer x1 Spring washer x1 ...

Страница 57: ... the support bracket between the copier and the heater harness Long on keeping the end of the heater harness Long in the hole To do step 22 easily be sure not to pass the heater harness Long completely thorough the hole 20 at the step of 21 23 Attach the edge saddle 21 to the support bracket 24 Attach the heater harness Long and the grounding wire Long through the edge saddle as shown 25 Pass the ...

Страница 58: ...7 28 31 Attach the clamp Mid 29 30 32 Connect the heater harness Long to the heater harness Mid 33 Attach the heater harness through the clamps as shown Be sure to make the bind attached on the heater harness upper than the clamp Mid 29 30 34 Remove the drawer from the lower paper tray unit 35 Attach the caution decal 31 in the bottom of the lower paper tray unit as shown 36 Reassemble the copier ...

Страница 59: ...PPER PTU 1 Remove each of the drawers 2 Insert the joint bracket Front 1 into the slot as the arrow shows and fasten x 2 3 Attach the joint bracket Rear 2 as shown x 2 The red arrow on the picture above shows the convex side of the screw hole This is the important clue to attach the bracket correctly ...

Страница 60: ...JOINT THE UPPER AND THE LOWER PTU 1 Attach the joint bracket Front 1 as shown x 2 2 Attach the joint bracket Rear 2 as shown x 2 The red arrow on the picture above shows the convex side of the screw hole This is the important clue to attach the bracket correctly ...

Страница 61: ... optional I F connections IEEE1284 IEEE802 11a g Wireless LAN or Gigabit Ethernet SD Card Slot Slot 1 is used for options provided on SD cards The application SD card Printer Scanner or Security Card should be installed in Slot 1 If more than one application is to be used move the applications to the same SD card with SP5873 Slot 2 is used for options provided on SD cards and servicing The VM card...

Страница 62: ...less Adapter 1 2 Wireless LAN Card 1 3 LAN Card Cover 1 4 Caution Sheet 1 5 Label 1 Installation Procedure 1 Remove the interface cover A x 2 2 Install the Wireless adaptor into I F slot B x 2 3 Install the Wireless LAN card in the wireless adaptor 4 Attach the antenna cap to the wireless LAN card 5 Turn on the main power switch 6 Print out the configuration page User Tools Counter Printer Feature...

Страница 63: ...IEEE 802 11a g SP No Name Function 5840 004 SSID Used to confirm the current SSID setting 5840 006 Channel MAX Sets the maximum range of the channel settings for the country 5840 007 Channel MIN Sets the minimum range of the channel settings allowed for your country 5840 011 WEP Key Select Used to select the WEP key Default 00 2 6 3 IEEE 1284 INSTALLATION Unplug the machine power cord before start...

Страница 64: ...cedure 1 Remove the interface cover A x 2 2 Install the IEEE 1284 board into I F slot B x 2 3 Turn on the main power switch 4 Print out the configuration page User Tools Counter Printer Features List Test Print and then check that this device is detected ...

Страница 65: ... TYPE S D656 Accessories Check the accessories and their quantities against the table below Accessories No Description Q ty 1 VM SD Card 1 2 Decal 1 Installation 1 Remove the interface cover A x 1 2 Switch the machine off 3 Insert the SD card A into SD Slot 2 lower ...

Страница 66: ...A x 2 2 Install the Gigabit Ethernet board Knob screw x 2 into the I F slot B 3 Attach one ferrite core A to the end of the Ethernet interface cable and then attach the other ferrite core B about 10cm from the end of the Ethernet interface cable 4 Connect the Ethernet interface cable to the Gigabit Ethernet port Make sure that the machine can recognize this option see Check All Connections at the ...

Страница 67: ...s embedded in the controller box Component Check No Description Q ty 1 Fax Unit 1 2 Speaker 1 3 Insulating Sheet 1 4 Screw for Fax Unit 4 5 Screw thin for Speaker 2 6 Screw thick for Grounding Wire 2 7 Harness with Band 1 8 Ferrite Core EU AP CN 1 9 Decal Super G3 1 10 Grounding Wire 2 11 Bracket Guide 1 12 Core attached Telephone Cord NA only 1 13 Ferrite Core 1 ...

Страница 68: ...t A and the bracket B x 4 3 Attach the Bracket Guide D as shown 4 Slot the bracket assembled in procedure 2 in between two of the guides as the blue arrow shows 5 Attach the large end of the Harness with the Band E and connect the small end to on the Fax Unit A as the red arrows shows 6 Attach the Speaker F and its connector to the large end of the Harness E ...

Страница 69: ...rom the end of the controller board This prevents the harness from being involved in the fan B Grounding Wire Attach the grounding wire as shown A and B are attached with screws thick for the grounding wire C and D are with screws for the controller board cover Be sure to make A B and C attached in upward direction ...

Страница 70: ...Controller Options D127 D128 2 38 SM 2 6 7 HDD OPTION D659 Component Check No Description Q ty 1 HDD Unit 1 2 Screw 6 3 SAT Interface Board 1 4 Cable Small 1 5 Cable Large 1 ...

Страница 71: ...Controller Options SM 2 39 D127 D128 Installation Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 4 Controller box cover A x 11 ...

Страница 72: ...tch on 9 Touch the Format button displayed with the message on start up 10 Turn the main power switch off on after the message directs to do so Installing the Security Card 1 Insert the Security Card in the SD slot For D127 use slot 2 lower and merge the Security Card into the Printer Scanner card with SP5 873 001 Remove the Security Card from the SD slot 2 after moving the security applications a...

Страница 73: ...entication If this setting is OFF tell the customer this setting must be ON before you do the installation procedure 3 Make sure that Administrator Tools is enabled selected System Settings Administrator Tools Administrator Authentication Management Available Settings If this setting is disabled not selected tell the customer this setting must be enabled selected before you do the installation pro...

Страница 74: ...is has been printed out earlier by the user into the nvram_key txt file 5 Remove only the HDD unit 6 Turn on the main power switch 7 Confirm that the prompt on the LCD tells you to install the SD card storing the encryption key in the machine 8 Turn off the main power switch 9 Insert the SD card that contains the encryption key into slot 1 10 Turn on the main power switch and the machine automatic...

Страница 75: ...m_key txt file 5 Turn on the main power switch 6 Confirm that the prompt on the LCD tells you to install the SD card storing the encryption key in the machine 7 Turn off the main power switch 8 Insert the SD card that contains nvclear into slot 1 9 Turn on the main power switch and the machine automatically restores the encryption key in the flash memory on the controller board 10 Turn off the mai...

Страница 76: ......

Страница 77: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...

Страница 78: ......

Страница 79: ...Maintenance Tables SM 3 1 D127 D128 Preventive Maintenance 3 PREVENTIVE MAINTENANCE 3 1 MAINTENANCE TABLES See Appendices for the following information PM tables ...

Страница 80: ...R Reset the PM counter after your maintenance work 1 Activate the SP mode 2 Select SP7 804 001 3 Press the EXECUTE The message Completed is displayed when the program ends normally An error message is displayed if the program ends abnormally 4 Press the Exit to end the program ...

Страница 81: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...

Страница 82: ......

Страница 83: ...uivalent type recommended by the manufacturer Discard used batteries in accordance with the manufacturer s instructions 4 1 3 HALOGEN FREE CABLE Use extreme caution while handling cables To comply with local regulations halogen free cables are used in this machine Halogen free cables are environment friendly but no stronger than conventional cables These cables may be damaged in any of the followi...

Страница 84: ...Special Tools and Lubricants D127 D128 4 2 SM 4 2 SPECIAL TOOLS AND LUBRICANTS Part Number Description Q ty B6455010 SD Card 1 52039502 Silicon Grease G 501 1 B6795100 Plug IEEE1284 Type C 1 ...

Страница 85: ...R 1 Open the right door A 2 Interface cover B x 1 3 Open the right door A 4 Rear cover C x 5 4 3 2 COPY TRAY Make sure that the cables under the copy tray are in place before reassembling the copier If these cables are caught between the copy tray and the inner cover they may be severely damaged 1 Open the front door A 2 Copy tray B x1 ...

Страница 86: ...28 4 4 SM 4 3 3 OPERATION PANEL 1 Remove the Scanner front cover A Hook 2 Remove the Right front cover B Hook 3 Remove the screws and the harnesses showed above for detaching the scanner unit 4 Scanner unit C x 5 x 4 5 Operation panel D x 5 x 2 ...

Страница 87: ...28 Replacement and Adjustment 4 3 4 RIGHT DOOR 1 Open the right door A 2 Release the strap B 3 Open the door fully and pull out 4 Right door x 1 4 3 5 BYPASS TRAY 1 Press the stopper rails A inward 2 Pull out with pressing the rails 3 Bypass Tray Hook ...

Страница 88: ...Exterior Covers and Operation Panel D127 D128 4 6 SM 4 3 6 PLATEN COVER AND ARDF SENSOR 1 Scanner Cover p 4 7 Scanner Cover and Exposure Glass 2 Platen cover sensor A x 1 hook ...

Страница 89: ...OSURE GLASS Exposure glass is united with Scanner cover To clean the exposure glass use alcohol or glass cleaner 1 Platen cover or ARDF p 4 46 ARDF Unit 2 Scanner front cover A Hook The front scanner cover is attached by 2 of the hooks the picture 1 shows Pulling the cover downward to keep the hooks off while removing makes detaching easy 3 Scanner cover B x 7 Hook ...

Страница 90: ... The oil doesn t exist in service parts 1 Scanner Cover and Exposure Glass p 4 7 Scanner Cover and Exposure Glass 2 Remove the long bracket A and the guide rod bracket B x 4 3 Lift the guide rod C as the red arrow shows 4 Put the belt D off as blue arrow shows to release the LED Unit E from the guide rod Do not loosen the paint locked screws holding the lens in place After installing a new lens ca...

Страница 91: ...from the scanner motor gear 2 Remove the screws on the top of the scanner motor B x 4 3 Turn the scanner motor B back Then remove the screws and the harness on the back x 2 x1 4 4 4 SCANNER HP SENSOR 1 Rear cover p 4 3 Rear Cover 2 Scanner Cover and Exposure Glass Scanner Cover and Exposure Glass 3 Two of the brackets A B and the rail C x 6 4 Scanner HP sensor D x 1 x 1 ...

Страница 92: ...nit make sure that the unit is cool enough The fusing unit can be very hot 1 Copy tray p 4 3 Copy Tray 2 Open the right door 3 Connector cover A x 1 When reinstalling attach the ground wire 4 Fusing unit B x 2 x 4 4 5 2 EXIT SENSOR 1 Fusing unit p 4 10 Fusing Unit 2 Exit sensor A x 1 ...

Страница 93: ...Unit 2 Separate the fusing unit into two sections the hot roller section A and the pressure roller section B x 2 After removing the screws lower the pressure roller section about halfway and then slide it toward the front side to detach it 3 Support rollers C 4 Hot roller stripper pawls D Remove the spacer E x 1 if you are removing the hot roller assembly p 4 12 Hot Roller and Fusing Lamp ...

Страница 94: ... spacers p 4 11 Hot Roller Stripper Pawls 2 Hot roller assembly A x 2 3 Fusing lamp B When reassembling check that the direction of the fusing lamp is correct 4 Hot roller C 2 C rings 1 spacer 1 gear 2 bushings 1 cover D Reassembling Be sure that The fusing lamp is positioned correctly The fusing lamp does not touch the internal part of the hot roller ...

Страница 95: ...sembly p 4 12 Hot Roller and Fusing Lamp 2 Thermoswitches A x 2 3 Thermistor B x 1 Reassembling Make sure of the following That the thermistor is in contact with the hot roller That the hot roller turns smoothly Do not recycle a thermoswitch that is already opened Safety is not guaranteed if you do this ...

Страница 96: ...128 4 14 SM 4 5 6 PRESSURE ROLLER 1 Separate the fusing unit into two sections p 4 11 Hot Roller Stripper Pawls 2 Fusing entrance guide A x 1 3 Two springs B C 4 Two pressure arms D E 5 Bushing F 6 Pressure roller G ...

Страница 97: ... by pass tray 2 Activate the SP mode 3 Select SP1 152 001 4 The copier feeds the OHP sheet and stops it between the hot roller and the pressure roller for about 40 seconds 5 Wait until the OHP sheet is output 6 After output quit the SP mode You see an opaque stripe on the OHP sheet This is the trace of the nip band The normal nip band is symmetrical on the OHP sheet Both ends are slightly thicker ...

Страница 98: ...damage the OPC drum surface Keep PCUs in a cool dry place Do not expose the OPC to any corrosive gas such as ammonia Do not shake a used PCU Remaining toner and developer may spill out Dispose of used PCUs in accordance with local regulations 4 6 1 PCU 1 Open the right door The PCU may become stuck if you try to remove it while the front door is closed 2 Open the front door 3 Remove the toner bott...

Страница 99: ...ble 5 When having installed a new PCU remove the Styrofoam and tags p 2 5 Copier in the chapter Installation Initialization After replacement Do SP2801 001 to initialize the copier setting for PCU 4 6 2 QUENCHING LAMP 1 PCU p 4 16 PCU 2 Remove the Lamp Shading A Adhered 3 Put the Quenching lamp B out as the blue arrow shows on pushing carefully as the red arrow shows x 1 ...

Страница 100: ...Exhaust Fan and Main Motor D127 D128 4 18 SM 4 7 EXHAUST FAN AND MAIN MOTOR 4 7 1 EXHAUST FAN 1 Rear cover p 4 3 Rear Cover 2 Exhaust fan A x 2 x 1 ...

Страница 101: ... MOTOR 1 Rear cover p 4 3 Rear Cover 2 High voltage power supply board p 4 38 High Voltage Power Supply Board 3 Ground plate A x 1 4 Main motor with the gear cover B x 1 x 7 x 2 2 bushings 5 All gears C 6 Main motor D x 3 Reassembling Attach the main motor before attaching the gears ...

Страница 102: ...27 D128 4 20 SM When you have difficulty in reattaching two of the snap rings remove the PCU to push the axles on the back of the main motor as the picture shows below Then the ditches in which the snap rings attach are pushed out ...

Страница 103: ...g the paper tray or the paper feed roller use caution Do not touch the surface of paper feed rollers To avoid paper jams correctly set the side and end fences in the paper tray 1 Paper tray 2 Shaft A x 1 3 Remove either or both of the following Paper feed roller B as the blue arrow shows Friction pad C as the red arrow shows ...

Страница 104: ...22 SM 4 8 2 PAPER END SENSOR 1 Draw the paper tray out from the copier 2 Open the right door 3 Paper end sensor A x 1 Hook Be sure to make the feeler be able to move up and down correctly when reattaching the Paper End Sensor ...

Страница 105: ...r tray 2 Open the right door 3 Open the paper guide A Remove the paper guide Clip x 1 if you have difficulty removing the registration sensor 4 Registration sensor feeler B 5 Registration sensor C x 1 Disconnect the connector CN127 D if you have difficulty removing the registration sensor ...

Страница 106: ... BYPASS PAPER END SENSOR 1 Right door p 4 5 Right Door 2 Sensor compartment A 3 Bypass paper end sensor B x 1 If it is difficult to reattach the Sensor compartment turn the feed roller housing upside down Bypass Feed Roller Procedure 2 ...

Страница 107: ...4 25 D127 D128 Replacement and Adjustment 4 8 5 BYPASS FEED ROLLER 1 Right door p 4 5 Right Door 2 Turn the feed roller housing upside down A x 2 3 Feed roller shaft B 2 snap pawls C 1 spacer D 4 Bypass feed roller E ...

Страница 108: ... BYPASS FEED CLUTCH AND FRICTION PAD 1 Rear cover p 4 3 Rear Cover 2 Right door p 4 5 Right Door 3 Disconnect the bypass feed clutch connector A CN93 4 Bypass feed roller housing B x 2 5 Bypass feed clutch C x 1 6 Bypass friction pad D ...

Страница 109: ...D AND REGISTRATION CLUTCHES 1 Paper tray 2 High voltage power supply board p 4 38 High Voltage Power Supply Board 3 Ground plate A x 1 4 Gear cover B x 1 x 7 x 2 2 bushings Do not remove the main motor from the gear cover 5 Ground plate C x 1 6 Paper feed clutch D x 1 x 1 ...

Страница 110: ...oller with your bare hands Do not scratch the transfer roller The transfer roller is easily damaged 1 Right door p 4 5 Right Door 2 Raise the levers A B at the ends of the image transfer roller 3 Release the image transfer roller C Reassembling Make sure that the springs D are in the original positions ...

Страница 111: ...y releasing the hook to lift one side of the lower guide A as the red arrow shows then lift the other side 3 Idle roller holders B 4 Idle roller C 5 Roller guide D x 2 6 Transfer unit F x 2 To remove the transfer unit easily insert a slotted screwdriver into the one side of the unit as the red arrow shows and lift to release Then release the other side ...

Страница 112: ...Duplex roller H x 1 3 bushings 9 ID sensor I x 1 If you have difficulty removing in the way of No 1 on the picture Put four of the hooks off in the bottom and make space through which you can take the sensor out But you don t need to remove the bottom cover ...

Страница 113: ...Image Transfer SM 4 31 D127 D128 Replacement and Adjustment 4 9 3 DISCHARGE PLATE 1 Right door p 4 5 Right Door 2 Discharge plate A Red arrow Hook Red circle Pressed ...

Страница 114: ... stop out of their home positions if you turn off the main power switch while they are operating The component may be damaged if you try to remove it when it is not in the home position 4 10 1 BICU Preparation Before replacing the NVRAM be sure to save the NVRAM data Saving from the BICU NVRAM to an SD card p 5 3 NVRAM Data Upload Download in the System Service Mode of the appendices of the this m...

Страница 115: ... data to the NVRAM From an SD card to the NVRAM p 5 3 NVRAM Data Upload Download in the System Service Mode of the appendices of this manual 4 10 2 CONTROLLER BOARD Preparation Before replacing the controller board be sure to print out SMC or save the NVRAM data Saving from the Controller NVRAM to an SD card p 5 3 NVRAM Data Upload Download in the System Service Mode of the appendices of this manu...

Страница 116: ...er A or I F options if they have been installed x 2 5 Remove the relay connector A and the clamp B 6 Remove the ground plate B x 1 7 Remove the controller board with the rails C x 6 8 Release the hooks as the red arrows show and then pull out the rails A 9 Remove the DIMM B if it has been installed ...

Страница 117: ...ery important Otherwise the HDD is automatically formatted and all data in the HDD is lost due to the security limitation 4 Reassemble the machine 5 Turn on the main power of the machine If the HDD option has not been installed the installation procedure is completed If the HDD option has already been installed go to next step 6 Turn off the main power of the machine and then connect the cables of...

Страница 118: ...canner card from SD slot 1 4 Install a new Security Card in SD slot 1 5 Turn the main switch on 6 SC995 02 occurs 7 Turn the machine off 8 Connect the cables of the HDD to the controller board 9 Reassemble the machine and then turn on the machine 10 Do the process control self check 11 Do ACC for the copier application program 12 Do ACC for the printer application program 13 Do SP5 878 001 to inst...

Страница 119: ...nt 4 11 OTHER REPLACEMENTS 4 11 1 DUPLEX MOTOR 1 Rear cover p 4 3 Rear Cover 2 High Voltage Power Supply Board p 4 38 High Voltage Power Supply Board 3 Main motor p 4 19 Main Motor 4 Exhaust Fan p 4 18 Exhaust Fan 5 SOL bracket x 4 6 Duplex Motor Bracket x 4 x 3 ...

Страница 120: ... SUPPLY BOARD 1 Rear cover p 4 3 Rear Cover 2 High voltage power supply board A with the cover B all x 4 Remove the insulating sheet C if you are going to remove the contact release solenoid p 4 40 Contact Release Solenoid or the gear cover p 4 27 Paper Feed and Registration Clutches ...

Страница 121: ...Other Replacements SM 4 39 D127 D128 Replacement and Adjustment 4 11 3 PSU 1 Open the front door 2 Copy tray p 4 3 Copy Tray 3 PSU assembly A x 7 x 10 4 PSU B x 8 x 7 ...

Страница 122: ...board p 4 38 High Voltage Power Supply Board 3 Contact release solenoid A 1 spring x 1 4 11 5 TONER SUPPLY MOTOR 1 Toner bottle holder 2 Hold both sides of the Toner Supply Clutch A as the red arrows show Then pull to your side with trying to release the upper hook the red square shows 3 Remove the harness the red circle shows ...

Страница 123: ...ith an equivalent type recommended by the manufacturer Discard used batteries in accordance with the manufacturer s instructions Procedure 1 Rear cover p 4 3 Rear Cover 2 Controller box cover A x 11 3 FCU A x 3 x 1 4 When you replace the FCU board remove the MBU board from the old FCU board and install it on the new FCU board 5 Set the correct date and time with the User Tools User Tools System Se...

Страница 124: ...Other Replacements D127 D128 4 42 SM Do not turn off the battery switch SW1 Do SP6 101 in the Fax SP to print the system parameters and check the settings ...

Страница 125: ...re starting replacement The laser beam can damage your eyes severely Do not touch the screws on the LD board on the LD unit Do not try to adjust any part of the LD unit The LD unit is precision adjusted before shipment Do not touch the polygon mirror shield glass or lenses with your bare hands 4 12 1 LOCATION OF THE CAUTION DECAL ...

Страница 126: ...Toner bottle holder 3 Remove 2 of the mylars Film sealing the holes on the bottom of the toner bottle rail 4 Laser unit A x 3 x 2 5 Replace the mylars Film with new ones The mylars are necessary to seal the holes in order for the laser unit not to be tainted with toner powder ...

Страница 127: ... MIRROR MOTOR 1 Laser unit p 4 44 Laser Unit 2 Laser unit cover A x 2 1 grounding plate 3 LD unit B x 2 4 Polygon mirror motor C x 3 Reassembling Check that the polygon mirror and toroidal lens are clean Dust or other foreign substances may interfere with the operation of the LD unit ...

Страница 128: ...4 46 SM 4 13 ARDF 4 13 1 ARDF UNIT 1 Rear cover p 4 3 Rear Cover 2 Remove the stud screw A 3 Remove the ground cable B x 1 4 Remove the clamp C 5 Disconnect the I F cable D 6 Remove the ARDF A from the copier as shown ...

Страница 129: ...sheet A on the exposure glass 3 Line up the rear left corner of the platen sheet flush against corner B on the exposure glass 4 Close the ARDF 5 Reopen the ARDF 6 Press the surface of the platen sheet gently to fix it on the ARDF firmly 4 13 2 ARDF REAR COVER 1 Open the ARDF left cover A 2 ARDF rear cover B x 1 ...

Страница 130: ...ARDF D127 D128 4 48 SM 4 13 3 ORIGINAL FEED UNIT 1 Open the ARDF left cover p 4 47 ARDF Rear Cover 2 Original feed unit A ...

Страница 131: ...ARDF SM 4 49 D127 D128 Replacement and Adjustment 4 13 4 PICK UP ROLLER 1 Original feed unit p 4 48 Original Feed Unit 2 Release the hook A 3 Slide the shaft A and then remove the pick up roller B ...

Страница 132: ...F D127 D128 4 50 SM 4 13 5 FEED ROLLER 1 Original feed unit p 4 48 Original Feed Unit 2 Remove the clip A 3 Slide the shaft A and then remove the pin B 4 Slide the shaft A and then remove the feed roller B ...

Страница 133: ...ARDF SM 4 51 D127 D128 Replacement and Adjustment 4 13 6 FRICTION PAD 1 Original feed unit p 4 48 Original Feed Unit 2 Turn the lock lever A clockwise 3 Friction pad A hook x 3 ...

Страница 134: ...7 DFRB 1 ARDF rear cover p 4 47 ARDF Rear Cover 2 DFRB A x 4 hook x 1 4 13 8 ARDF TOP COVER SENSOR ORIGINAL SET SENSOR 1 ARDF rear cover p 4 47 ARDF Rear Cover 2 ARDF top cover sensor A x 1 hooks 3 Original set sensor B x 1 hooks ...

Страница 135: ...4 53 D127 D128 Replacement and Adjustment 4 13 9 ARDF DRIVE MOTOR 1 ARDF rear cover p 4 47 ARDF Rear Cover 2 Guide plate A hook x 2 3 Guide plate A x 5 4 Release the clamps and disconnect the connectors x 3 x 2 ...

Страница 136: ...ARDF D127 D128 4 54 SM 5 Holder A x 1 6 Hinge A x 3 7 Bracket A x 2 ...

Страница 137: ...d Adjustment 8 ARDF drive motor A x 2 x 1 Do not touch the encoder B when holding the motor 4 13 10WHITE PLATE 1 Open the ARDF 2 White plate A hook x 2 When installing the white plate Make sure that the mylars A are outside the white plate ...

Страница 138: ...ARDF D127 D128 4 56 SM 4 13 11REGISTRATION SENSOR 1 White plate p 4 55 White Plate 2 Registration sensor holder A x 1 3 Registration sensor A x 1 hooks ...

Страница 139: ... 14 1 PRINTING Make sure that the paper is correctly loaded in each paper tray before starting the adjustment procedures in this section Adjusting Registration Use the Trimming Area Pattern SP2 109 001 10 for this adjustment 1 Print out the test pattern with the paper fed from the regular paper tray 2 Print out the test pattern with the paper fed from the by pass tray 3 Print out the test pattern ...

Страница 140: ...plex 0 4 mm 5 Adjust the leading edge registration SP1 001 6 Measure the distance between the side edge of the image area and the side edge of the paper B SP Specification SP1 002 001 1st tray 0 2 mm SP1 002 002 2nd tray 0 2 mm SP1 002 003 3rd tray 0 2 mm SP1 002 004 By pass 0 4 mm SP1 002 005 Duplex 0 4 mm 7 Adjust the side to side registration SP1 002 8 Select Cancel in SP2 109 001 after finishi...

Страница 141: ...iagram shows the paper on the copy tray Note that the paper is output with the face down 3 Adjust the blank margin SP2 103 SP Specification SP2 103 001 Leading Edge A 3 1 3 mm SP2 103 002 Trailing Edge B 3 1 3 mm SP2 103 003 Left Side C 2 2 mm SP2 103 004 Right Side D 2 2 mm The Left Side and Right Side comes to your left hand side and right hand side respectively when you view the copied image wi...

Страница 142: ...er finishing the adjustment procedure 4 14 2 SCANNING Preparation Before adjusting scanning adjust printing p 4 57 Printing To adjust scanning use the A4 test chart Adjusting Registration 1 Place the test chart on the exposure glass Make sure that the test chart is aligned with the rear and left scales on the exposure glass 2 Make a copy 3 Measure the distance between the leading edge of the image...

Страница 143: ...ion SP4 011 001 SP Specification SP4 011 001 S to S Scan Regist 0 2 mm Adjusting Magnification 1 Place the test chart on the exposure glass Make sure the test chart is aligned with the rear and left scales on the exposure glass 2 Make a copy 3 Compare the copy with the original 4 Adjust the main scan and sub scan magnifications The original image A is magnified in the main scan direction B or in t...

Страница 144: ...NT Perform the adjustment procedure in this section only when the ARDF is installed on the copier 1 Make a temporary test chart as shown in the above diagram Use the A4 8 5 x 11 paper to make it 2 Place the temporary test chart on the ARDF 3 Make a copy 4 Measure the distance between the side edge of the image area and the side edge of the paper A The diagram shows the paper on the copy tray Note ...

Страница 145: ...ing of the image area and the leading edge of the paper B 7 Adjust the leading edge registration Leading Regist SP6 006 003 The image area moves to the right side of the copier when you specify a larger value 8 Measure the distance between the trailing edge of the image area and the trailing edge of the paper C 9 Adjust the erased area on the trailing edge Trailing Erase SP6 006 007 10 Compare the...

Страница 146: ......

Страница 147: ...SYSTEM MAINTENANCE REFERENCE REVISION HISTORY Page Date Added Updated New None ...

Страница 148: ......

Страница 149: ... SP mode 5 1 1 SP TABLES See Appendices for the following information System SP Tables Printer SP Tables Scanner SP Tables 5 1 2 USING SP AND SSP MODES The following two modes are available SP Mode Service Program Mode The SP Mode includes the programs that are necessary for standard maintenance work SSP Mode Special SP Mode The SSP Mode includes SP Mode programs and some special programs You need...

Страница 150: ...he copier outputs images or patterns that help you adjust the SP setting 1 Press the key E The copy mode is activated 2 Specify copy settings and press the key E 3 To return to the SP mode touch the item To SP displayed on the upper left corner on the panel You cannot end the SP mode while the copy mode is activated Quitting Programs Ending S SP Mode Touch the item Exit displayed on the upper righ...

Страница 151: ...NVRAM serial number NV Here is an example with Serial Number B0700017 NVRAM B0700017 NV 6 In order to prevent an error during the download be sure to mark the SD card that holds the uploaded saved data with the number of the machine from which the data was uploaded saved NVRAM data from more than one machine can be uploaded saved to the same SD card 7 Turn off the main power and then remove the SD...

Страница 152: ...on device so always observe the following precautions when handling SD cards Always switch the machine off before inserting an SD card Never insert the SD card into the slot with the power on When the power is switched on never remove the SD card from the service slot Never switch the machine off while the firmware is downloading from the SD card Store SD cards in a safe location where they are no...

Страница 153: ...r Firmware Update Do not put multiple machine firmware programs on the same SD card Copy the only model firmware you want 1 Turn off the main power switch 2 If the machine is connected to a network disconnect the network cable from the copier 3 Remove the interface cover x 1 4 With the label on the SD card facing the rear side of the machine insert the SD card into the slot 2 on the controller box...

Страница 154: ...s on and off at 0 5 s intervals when the LCDC firmware is updating The power key flashes on and off at 3 s intervals when the update is finished 9 The Update is Done message appears on the operation panel after completing the updating The message differs depending on the firmware that has been updated 10 Switch the copier main power switch off when you see the Update is Done message or follow the ...

Страница 155: ...cidental loss of power while the firmware is updating then the correct operation of the machine cannot be guaranteed after the machine is switched on again If the ROM update does not complete successfully for any reason then in order to ensure the correct operation of the machine the ROM update error will continue to show until the ROM is updated successfully In this case insert the card again and...

Страница 156: ...user name and password 7 Touch Extended Feature Settings twice on the LCD 8 Touch Uninstall on the LCD 9 Touch the Browser line 10 Confirmation message appears on the LCD 11 Touch Yes to proceed 12 Reconfirmation message appears on the LCD 13 Touch Yes to uninstall the browser unit 14 You will see Uninstalling the extended feature Please wait and then Completed 15 Touch Exit to go back to the sett...

Страница 157: ...access error Make sure SD card inserted correctly or use another SD card 30 No HDD available for stamp data download HDD connection incorrect or replace hard disks 31 Data incorrect for continuous download Insert the SD card with the remaining data required for the download the re start the procedure 32 Data incorrect after download interrupted Execute the recovery procedure for the intended modul...

Страница 158: ...panel module download failed Replace the update data for the module on the SD card and try again or replace the LCDC 43 Stamp data module download failed Replace the update data for the module on the SD card and try again or replace the hard disks 44 Controller module download failed Replace the update data for the module on the SD card and tray again or replace controller board 50 Electronic conf...

Страница 159: ...e key 4 To return to the SP mode Touch the item To SP displayed on the upper left corner on the touch panel Test Patterns No Pattern 0 None 1 Vertical Lines 1 Dot 2 Vertical Lines 2 Dot 3 Horizontal Lines 1 Dot 4 Horizontal Lines 2 Dot 5 Grid Vertical Line 6 Grid Horizontal Line 7 Grid Pattern Small 8 Grid Pattern Large 9 Argyle Pattern Smell 10 Argyle Pattern Large 11 Independent Pattern 1 Dot 12...

Страница 160: ...een the engine data and the other data see SP5 801 003 through 015 This service program SP5 801 handles the controller data The data in the BICU NVRAM engine data is cleared by SP5 801 002 while the data in the controller NVRAM controller data is cleared by the other programs in SP5 801 for exceptions see Exceptions as described below Data NVRAM Cleared by Remarks Engine data BICU SP5 801 002 Any ...

Страница 161: ...replaced the controller NVRAM or when the controller NVRAM data is corrupted use SP5 801 001 The message is the same as the basic machine Memory Clear Procedure 1 Print out all SMC data lists p 5 14 SMC Print SP5 990 2 Do SP5 801 002 3 Press the OK key 4 Select Execute The messages Execute followed by Cancel and Execute are displayed 5 Select Execute 6 When the program has ended normally the messa...

Страница 162: ...2 8 ID SENSOR ERROR ANALYSIS SP2 220 The image quality may become very bad when the ID sensor does not operate properly However there is no such SC code that indicates ID sensor malfunction instead SP2 220 shows you some information on the ID sensor Check this information when the image quality is not very good The table lists the information shown with SP2 220 Vsg Vsp Vsdp Vt Vtref Dilay SP Error...

Страница 163: ...M 5 15 D127 D128 System Maintenance Reference 5 3 FAX SERVICE TABLES See Appendices for the following information Fax System Service Mode Bit Switches NCU Parameters Dedicated Transmission Parameters Service RAM Addresses ...

Страница 164: ......

Страница 165: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None ...

Страница 166: ......

Страница 167: ...etection Turn the main power switch off and on C The machine operates as usual excluding the unit related to the service call Turn the main power switch off and on D The SC history is updated The machine operates as usual No SC code is displayed Only the SC history is updated If a problem involves circuit boards see if you can solve the problem by disconnecting and reconnecting all connectors befo...

Страница 168: ...tion sensor does not detect the scanner leaving the home position Defective scanner home position sensor Defective scanner home position sensor harness Defective scanner motor drive Defective scanner motor 121 B Scanner home position error 2 The scanner home position sensor does not detect the scanner coming back to the home position Defective scanner home position sensor Defective scanner home po...

Страница 169: ...unication Error Cannot correctly establish communication with the SBU Defective relevant harness Defective destination device e g BICU etc Defective SBU 161 IPU error 001 B LSYNC error Detecting an error from the result of the IPU self check on startup Defective the IPU or the BICU or bad connection between the ASIC and the LEO LSYNC Abnormal etc Cable bad connection between the SBU and the IPU or...

Страница 170: ...nder setting unauthorized copy protection on Or detecting wrong with the ICIB on startup NOT the ICIB attached firmly Defective the ICIB 202 B Polygon motor error Time out On NOT detecting making the polygon motor be ready in certain time after start polygon motor up or change the spin speed Harness and the polygon motor driver Defective the polygon motor or the polygon motor driver Defective poly...

Страница 171: ...n or disconnection between the I F 204 B Polygon motor error XSCRDY signal error Detecting XSCRDY signal H Inactive while writing Harness and the polygon motor driver Defective the polygon motor or the polygon motor driver Bad connection or disconnection between the I F 220 B LD synchro detection error NOT output certain syncro detection signal within 200ms after LD lighting in steady rotation Bad...

Страница 172: ...ng BICU the Controller board wrong or bad connection Defective the harness between the BICU to the LDB Defective the GAVD PCI bridge ASIC 240 D LD error Detecting two LD error flags in series when LD lighting after the LD initializing Characteristic degradation of the LD LD broken electric current versus light output characteristic shift etc Bad connection or disconnection of the harness to the LD...

Страница 173: ...on of the harness to P sensor Bad electrical contact of P sensor CN Defective the BICU Defective the writing section Defective developer density Defective high voltage PP Uncleanness of the P sensor Defective the P sensor 389 D T sensor error warning Detected the following value T sensor output value 0 2V T sensor output value 4 0V 10 times in series Defective the T sensor Bad contact of the conne...

Страница 174: ... output is more than 2 5V SC appears in the case of not removing the heat seal or an absence of developer Defective P sensor Defective T sensor NOT removing heat seal Defective drum operation Defective development roller operation 401 B Transfer roller leak error positive electrode The feedback voltage of the transfer roller has been more than the certain voltage for 200msec Open detecting conditi...

Страница 175: ...ion high voltage error The maximum rate of PWM duty 50 occurs ten times in series 20msec x 10 This error doesn t happen when the front door the inter lock opens Defective the MD HVP Connection harness 440 B Transfer electric plus current error Detecting 0 Abnormal ten times in series 200ms while monitoring HVP T Output error detection signal every 20m seconds Reboot the machine to clear this SC 46...

Страница 176: ...verload Defective main motor drive 541 A Fusing thermistor disconnection Detecting the temperature remains lower than 0 degrees Celsius for 5 seconds Thermistor disconnection Defective connector part 542 Fusing reload failed 001 A Fusing temperature warm up error The fusing temperature doesn t rise by more than 7 degrees for two seconds and this happens 5 times consecutively The measure is start i...

Страница 177: ...30 C or higher for one second Defective the triac Semiconductor device Defective the IOB control board Detective the BICU control board 544 A Fusing overheat error 2 The fusing temperature detected by the monitor circuit is 250 C or higher Defective the triac Semiconductor device Defective the IOB control board Defective the BICU control board Uncontrollable fusing condition 545 A Fusing lamp over...

Страница 178: ...59 A Consecutive fusing jam The paper jam counter for the fusing unit reaches 3 times The paper jam counter is cleared if the paper is fed correctly This SC is activated only when SP1159 001 is set to 1 default 0 Paper jam in the fusing unit 620 B ADF communication error Disconnection after connection in normal Defective the ADF Defective the IPU board Bad connection of the ADF 622 B Bank communic...

Страница 179: ...ror Cannot return to be normal condition after retrying three times when the error on EEPROM communication occurs Defective the EEPROM Noise 687 B Cannot receive RAPI PER Command Ready for image transfer in 120 seconds after RARI PES Request for image transfer occurs Defective the controller board Noise 790 B Over the number of the banks installed error Receiving a code other than the following co...

Страница 180: ...Anti tampering system is ON Defective harness between mechanical counter and BICU Defective BICU Defective mechanical total counter Loose connection of harness between mechanical counter and BICU Mechanical counter has been pulled out while accounting operation 995 B Model information error NOT according manufacturing number 11 digits with product identification code Defective BICU Defective NVRAM...

Страница 181: ... MF accounting device error 2 The machine is communicating with the accounting device The break signal returns Defective or broken line between machine and device 634 C MF accounting device error 3 A backup RAM error is reported from the accounting device Defective accounting device controller Defective battery in the accounting device 635 C MF accounting device error 4 A battery voltage error is ...

Страница 182: ...rror The version of the expanded authentication module is not correct 1 Install the correct file of the expanded authentication module 011 B OSM usercode file error NOT found the usercode file in the rootfolder in the SD card Or cannot read the usercode file correctly This SC occurs only for OSM IC card No usercode file exists in the SD card Irregular usercode file The data in the usercode file is...

Страница 183: ...F ON 002 B Administration server error NOT found the tracking information Defective tracking administration server Defective tracking SDK APP Defective Network 1 Power source OFF ON 640 D Engine to controller communication error Check Sum error Incorrect sum data Defective the PCI related hardware 641 B Engine to controller communication error No response No response to the frame from the engine w...

Страница 184: ...efective communication line or defective connection 1 Consult with the user s local telephone company 651 Incorrect dial up connection An unexpected error occurs when the modem RCG M tries to call the center with a dial up connection 001 D Program parameter error Software bug 1 No action required because this SC does not interfere with operation of the machine 002 D Program execution error 670 B E...

Страница 185: ...etween the controller and operation panel does not begin or the communication is interrupted after a normal startup Controller stalled Controller board installed incorrectly Defective controller board Operation panel connector loose or defective Poor connection of DIMM and optional boards on the controller board 1 Check the setting of SP5875 001 If the setting is set to 1 OFF change it to 0 ON ...

Страница 186: ...system files from the OS Flash ROM or the items on the SD card in the controller slot are false or corrupted OS Flash ROM data defective change the controller firmware SD card data defective use another SD card 819 Kernel stop Due to a control error a RAM overflow occurred during system processing One of the following messages was displayed on the operation panel 5032 B HAIC P2 error System progra...

Страница 187: ... Detailed error code Cache access error in the CPU Defective CPU Defective local bus 1 Turn the main power switch off and on 2 Reinstall the system program 3 Replace the controller board B 0601 0602 0605 0606 0607 0609 Detailed error code Exceptional command does not operate even though it is executed on purpose Defective CPU devices 1 Replace the controller board B 060A 060E Detailed error code C...

Страница 188: ...702 Detailed error code The result when the program is executed in the command cache is different from desirable value Insufficient CPU cache Insufficient memory process speed 1 Replace the controller board 2 Replace the RAM DIMM B 0709 070A Detailed error code Even you write the data in the only cache of memory the data is actually written in another area not cache of memory Defective CPU devices...

Страница 189: ...r board defective Poor connection between North Bridge and PCI I F 1 Replace controller board 0D05 B Timer error between ASIC and CPU The CPU checks if the ASIC timer works properly compared with the CPU timer If the ASIC timer does not function in the specified range this SC code is displayed System firmware problem Defective RAM DIMM Defective controller Reinstall the controller system firmware ...

Страница 190: ...e main switch is turned on or starting the self diagnostic the HDD stays busy for the specified time or more 3003 C Timeout error Loose connection Defective HDD Defective controller 1 Check that the HDD is correctly connected to the controller 2 Replace the HDD or the controller 3004 C Command error 823 Self diagnostic Error NIB 6101 C MAC address check sum error The result of the MAC address chec...

Страница 191: ...connection Defective standard NVRAM Defective controller 1 Check the standard NVRAM is firmly inserted into the socket 2 Replace the NVRAM 3 Replace the controller 826 B Self diagnostic Error RTC Optional NVRAM 1501 Clock error An RTC device is recognized and the difference between the RTC device and the CPU exceeds the defined limit No RTC device is recognized RTC defective 1 Replace the RTC devi...

Страница 192: ...M DIMM Defective SPD ROM on RAM DIMM Defective 12C bus 1 Replace the RAM DIMM 828 Self diagnostic Error ROM 0101 B Boost lap code error The boot monitor and OS program stored in the ROM DIMM is checked If the check sum of the program is incorrect this SC code is displayed Defective ROM DIMM Defective controller 1 Replace the ROM DIMM 2 Replace the controller 829 B Self diagnostic Error Optional RA...

Страница 193: ...ice error IEEE1284 connector error Centronic loopback connector defective 1 Replace the controller board 1120 C Centronic loopback connector is not connected for detailed self diagnostic test Centronic loopback connector not connected correctly Centronic loopback connector defective ASIC device defective 1 Replace the controller board 838 2701 B Self diagnostic Error Clock Generator A verify error...

Страница 194: ...ller board 9110 B The USB NAND Flash ROM is disconnected 840 B EEPROM access error While I O operation to EEPROM Three times retry is ineffective after reading error Writing error occurs Defective EEPROM 841 B EEPROM reading error All of the data values being read from three areas which are given EEPROM mirroring are different from each other Particular area in EEPROM has been changed by some caus...

Страница 195: ...d The machine loses access to the card the wireless LAN card or bluetooth card connection board is still recognized Loose connection between the wireless card and the connection board 855 C Wireless card error Some illegal data is found in the card Defective wireless card 856 C Wireless card connection board error An error is detected in the wireless LAN card or bluetooth card connection board Def...

Страница 196: ...ller board 1 Encryption key setting for HDD error The controller fails to copy a new encryption key to the HDD Defective SATA chip on the controller board 1 Replace the controller board 2 NVRAM data encryption error 1 An error occurs while the NVRAM data is encrypted Defective NVRAM on the controller board 1 Replace the NVRAM 30 NVRAM data encryption error 2 An error occurs before the NVRAM data i...

Страница 197: ...1 Install the HDD correctly 2 Initialize the HDD 9 Power failure during the data encryption The data encryption NVRAM and HDD has not been completed Power failure during the data encryption 1 Initialize the HDD 10 Data read write error The DMAC error is detected twice or more Same as SC863 860 HDD Initialization error B The controller detects that the hard disk fails HDD not initialized Defective ...

Страница 198: ... or storing data in the HDD data transmission fails Defective HDD 1 Replace the HDD 865 HDD Access error C An error is detected while operating the HDD Defective HDD 1 Replace the HDD 866 C SD card authentication error A digital license error of an SD card application is detected SD card data has corrupted 1 Store correct data in the SD card 867 B SD card error An application SD card is removed fr...

Страница 199: ...the SD card 5 Replace the controller 870 C Address book data error The address book in the hard disk is accessed An error is detected in the address book data address book data is not read or data is not written into the address book Data corruption Defective hard disk Defective controller software 1 Replace the hard disk the user codes and counters are recovered when the main switch is turned on ...

Страница 200: ...g to the HDD 1 SP5832 008 Format Sed Mail to initialize the HDD 2 Replace the HDD 874 B Mass erasing error Data area erasing HDD NVRAM data erasing error was detected The case you went out from the mode while operating before finishing mass erasing HDD NVRAM data erasing option this SC occurs HDD erasing program detected an error An error occurs while NVRAM data erasing Unset erasing program mass ...

Страница 201: ...r An error was detected in the handling of the log data at power on or during machine operation This can be caused by switching the machine off while it is operating 001 C Log Data Error 1 Damaged log data file in the HDD 1 Initialize the HDD with SP5832 004 002 C Log Data Error 2 An encryption module not installed 1 Disable the log encryption setting with SP9730 004 0 is off 2 Install the DESS mo...

Страница 202: ... 99 Other than the above causes 1 Ask your supervisor 877 00 C HDD erasing error Cannot operate successive erasing of the hard disc encryption unit under the condition of the successive erasing setting ON SD card for the hard disc encryption unit is ejected Defective SD card for the hard disc encryption unit 1 The case that the SD card is ejected insert a normal condition SD card for the unit into...

Страница 203: ...er board 01 B USB Flash error Defective file system of USB Flash memory USB Flash file system is broken 1 Replace the controller board 02 B TPM error Defective TPM or TPM drive Defective TPM 1 Replace the controller board 03 B TCSD error Defective TPM Software Stack Cannot start TPM Software Stack up NOT found necessary files for TPM Software Stack 1 Replace the controller board 880 B File Format ...

Страница 204: ... Login from the panel 3 Accessing from WEB browser Caused by stored un authentication information in the software NOT caused by user operation 1 Reboot the machine 899 B Software operation error Receiving signal end Abnormal operation occurs in the controller program Hardware or Software 1 Reboot the machine 2 Update the firmware 3 If this SC does not clear with No 1 2 processes replace the contro...

Страница 205: ...Unexpected hardware resource e g memory shortage 921 C Printer font error A necessary font is not found in the SD card when the printer application starts A necessary font is not found in the SD card The SD card data is corrupted 1 Check that the SD card stores correct data 925 Net file error C The management file for net files is corrupted net files are not normally read Netfiles Jobs to be print...

Страница 206: ...the situation in which this SC occurs Then report the data and conditions to your technical control center Software defective Internal parameter incorrect Insufficient working memory 991 D Software continuity error The software attempted to perform an unexpected operation However unlike SC990 the process can keep on running Logged only the machine can continue to operate 992 B Undefined error An e...

Страница 207: ...on selected by a key press on the operation panel does not start or ends abnormally Software for that application is defective An option required by the application RAM DIMM board is not installed Too complicated nest of the fax group address 1 As for the fax operation problem simplify the nest of the fax group address 998 B Application start error After switching the machine on the application do...

Страница 208: ...The machine cannot detect paper on the bypass tray SN Paper Path Sensor CN128 Paper jam SN Exit Sensor CN128 Paper jam SN Image Density ID Sensor CN132 None Print quality may become worse SN Toner Density TD Sensor CN123 SC901 The connector is shared with the mechanical total counter PCU Reset PCU correctly Scanner HP Sensor CN404 SC120 SN SC120 Platen Cover Sensor CN404 SC120 SN None The copier d...

Страница 209: ...on Sensor DF CN03 Paper jam SN Originals are correctly transported Inverter Sensor DF CN03 Paper jam SN None Exit Sensor DF CN04 Paper jam SN Front Door Switch CN114 Front door open SW Front door open Right Door Switch CN114 Right door open SW Right door open CNxxx The connector on the BICU board DF CNxxx The connector on the DF connection board SN The connector on the sensor SW The connector on t...

Страница 210: ...ent Defects D127 D128 6 44 SM 6 2 2 BLOWN FUSE CONDITIONS All of these fuses are on the power supply unit Fuse Rating At main switch ON 100 127 V 250 V FU1 15A 250V 8A 250 V No response FU2 8A 250 V 4A 250 V No response ...

Страница 211: ...function Previously stored files on the SD card can be overwritten or left intact Card Save SD has Add and New menu items Card Save Add Appends files to the SD Card Does not overwrite existing files If the card becomes full or if all file names are used an error will be displayed on the operation panel Subsequent jobs will not be stored Card Save New Overwrites files in the card s prt cardsave dir...

Страница 212: ...st Print 1 Select Card Save ADD or Card Save New 2 Select OK to the message Switching to Card Save mode Then exit the List Test Print menu 3 Send a job to the printer 4 As soon as the printer receives the data it will be stored on the SD card automatically with no print output Nothing is displayed on the screen indicating that a Card Save operation was successful 5 To exit Card Save mode Change th...

Страница 213: ...tection change to kernel mode failed to initialize Card not found Card cannot be detected in the slot No memory Insufficient working memory to process the job Write error Failed to write to the card Other error An unknown error occurred If an error occurs pressing OK will cause the device to discard the job and return to the ready state ...

Страница 214: ...Fax Troubleshooting Guide D127 D128 6 48 SM 6 4 FAX TROUBLESHOOTING GUIDE See Appendices for the following information Fax Error Codes IFAX Troubleshooting IP Fax Troubleshooting ...

Страница 215: ...ENERGY SAVING REVISION HISTORY Page Date Added Updated New None ...

Страница 216: ......

Страница 217: ...ear and no energy is saved before 240 min expires Timer Settings Sleep Mode Timer After a specified period has passed or the Energy Saver key is pressed the machine enters Sleep Mode in order to conserve energy Specify the time to elapse before Sleep Mode You can specify this setting only if Sleep Mode is set to Enable in Administrator Tools in System Settings Default 1 minute The time can be set ...

Страница 218: ...Y SAVE EFFECTIVENESS SP 8941 Machine Status keeps a record of the amount of time that the machine spends in each mode 8941 001 Operation mode 8941 002 Ready mode 8941 005 Sleep mode With this data and the power consumption values from the specifications we can estimate the amount of energy that is used by the machine This should only be used as a reference value because the power consumption speci...

Страница 219: ... x Data d Wmin Data e Operation mode 1081 8 001 Operating Time 21089 0 21386 0 297 0 321294 6 Ready mode stand by 214 0 002 Standby Time 306163 0 308046 0 1883 0 402962 0 Sleep mode 7 0 005 Off mode Time 508776 0 520377 0 11601 0 81207 0 Total Time of Data d min 13781 0 Total Time of Data d 60min Hour 229 68 Total Power Consumption of Data e Wmin 805463 60 Total Power Consumption of Data e 60min 1...

Страница 220: ...DUPLEX COMBINE FUNCTION Duplexing and the combine functions reduce the amount of paper used This means that less energy overall is used for paper production which improves the environment 1 Duplex Reduce paper volume in half 2 Combine mode Reduce paper volume in half ...

Страница 221: ...e duplex page the total counter goes up by 2 For a duplex job of a three page original the total counter goes up by 3 The duplex counter counts pages that have images on both sides For one duplex page the duplex counter goes up by 1 For a duplex job of a three page original the duplex counter will only increase by 1 even though two sheets are used Recommendation Please explain the above features t...

Страница 222: ...s of single sided and duplex jobs Duplex mode Originals Simplex Sheet used Duplex Sheets used Paper Saved Total counter SP8501 001 Duplex counter SP8411 001 1 1 1 0 1 0 2 2 1 1 2 1 3 3 2 1 3 1 4 4 2 2 4 2 5 5 3 2 5 2 10 10 5 5 10 5 20 20 10 10 20 10 If combine mode is used the total and duplex counters work in the same way as explained previously The following table shows paper savings and how the...

Страница 223: ... Energy Saving 2 in 1 mode Originals Simplex Sheet used Duplex Sheets used Paper Saved Total counter SP8501 001 Duplex counter SP8421 004 1 1 1 0 1 1 2 2 1 1 1 1 3 3 2 1 2 2 4 4 2 2 2 2 5 5 3 2 3 2 10 10 5 5 5 5 20 20 10 10 10 10 ...

Страница 224: ...als Simplex Sheet used Duplex Sheets used Paper Saved Total counter SP8501 001 Duplex counter SP8421 005 1 1 1 0 1 1 2 2 1 1 1 1 3 3 1 2 2 2 4 4 1 3 2 2 5 5 2 3 3 3 6 6 2 4 3 3 7 7 2 5 4 4 8 8 2 6 4 4 9 9 3 6 5 5 10 10 3 7 5 5 11 11 3 8 6 6 12 12 3 9 6 6 ...

Страница 225: ...D127 D128 SERVICE MANUAL APPENDICES ...

Страница 226: ......

Страница 227: ... 11 1 2 SUPPORTED PAPER SIZES 1 12 1 2 1 ORIGINAL PAPER SIZES 1 12 1 2 2 PAPER FEED 1 14 2 APPENDIX PREVENTIVE MAINTENANCE TABLES 2 1 2 1 MAINTENANCE TABLES 2 1 3 APPENDIX SP MODE TABLES 3 1 3 1 SYSTEM SERVICE MODE 3 1 3 1 1 SERVICE MODE TABLES SYSTEM SP TABLES 3 1 SP1 XXX Feed 3 1 SP2 XXX Drum 3 9 SP4 XXX Scanner 3 24 SP5 XXX Mode 3 41 SP6 XXX Peripherals 3 95 SP7 XXX Data Log 3 98 SP8 XXX Data L...

Страница 228: ...Address Host Name 4 24 Cannot send via VoIP Gateway 4 25 Cannot send by Alias Fax number 4 26 4 3 2 IP FAX RECEPTION 4 28 Cannot receive by IP Address Host name 4 28 Cannot receive by VoIP Gateway 4 29 Cannot receive by Alias Fax number 4 30 5 APPENDIX FAX SERVICE PROGRAM 5 1 5 1 SYSTEM SERVICE MODE 5 1 5 1 1 SP1 XXX BIT SWITCHES 5 1 5 1 2 SP2 XXX RAM 5 2 5 1 3 SP3 XXX MACHINE SET 5 3 5 1 4 SP4 XX...

Страница 229: ...SM Appendix iii D127 D128 5 4 DEDICATED TRANSMISSION PARAMETERS 5 83 5 4 1 PROGRAMMING PROCEDURE 5 83 5 4 2 PARAMETERS 5 84 Fax Parameters 5 84 E mail Parameters 5 88 ...

Страница 230: ......

Страница 231: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...

Страница 232: ......

Страница 233: ...aximum A4 SEF 81 2 x 11 SEF Copier s paper tray A4 SEF 81 2 x 14 SEF Bypass A4 SEF 81 2 x 14 SEF Optional paper tray A4 SEF 81 2 x 14 SEF Duplex Minimum A5 LEF 81 2 x 51 2 LEF Copier s paper tray A6 SEF 81 2 x 51 2 Bypass A4 SEF 81 2 x 11 SEF Optional paper tray unit A4 SEF 81 2 x 11 SEF Duplex Custom sizes in the bypass tray Width 90 216 mm 3 5 8 5 Length 139 600mm 5 48 23 62 Copy Paper Weight St...

Страница 234: ...5 W or less Sleep Mode SP 2 8 W SPF 3 1 W NA SP 3 0 W SPF 3 3 W EU Off Mode None Noise Emission Sound Power Level Standby 40 dB Operating copier only 66 5 dB Operating full system 70 5 dB Dimensions W x D x H Copier 476 x 450 x 371 mm 19 4 x 18 x 14 8 With optional paper tray unit 485 x 454 x 511 mm 18 4 x 17 7 x 20 1 Weight 23 kg or less 26kg or less including ARDF The weights do not include tone...

Страница 235: ...r Input Numeric keypad 1 to 99 increment decrement Manual Image Density 7 steps Auto Off Timer Default 1 minute Range 1 to 240 minutes Energy Saver Timer Default 1 minute Rage 1 to 240 minutes Copy Paper Capacity Paper Tray 250 sheets Optional Paper Tray Unit 500 sheets x 1 Bypass Tray 100 sheets Copy Tray Capacity 250 sheets Toner Replenishment Cartridge replacement 230 g cartridge Toner Yield 8k...

Страница 236: ...hernat 1000BASE T option Bluetooth V2 option Network protocol TCP IP IPv4 IPv6 IPX SPX Printer language RPCS PCL5e 6 XL PostScript3 Adobe PS3 PDF Media Print JPEG TIFF Resident Fonts PCL 45 fonts 13 International fonts PS 136 fonts Euro Currency supported Memory 1GB OS supported Windows XP Vista 7 Server 2003 Server2008 or later MacOS8 6 to 9 MacOSX10 1 or later Required network cable 100BASE TX 1...

Страница 237: ...wer consumption Less than 900 W Image sensor type CCD Image Sensor Scan types Sheet book Interface 10 100BASE TX TCP TP Ethernet interface 10BASE T or 100BASE TX IEEE 802 11a b g Wireless LAN Resolution B W 600 dpi Variable range of scan resolution Setting range 100 dpi 600 dpi 1 Scanning speeds vary according to machine operating conditions computer specifications network traffic software etc and...

Страница 238: ...sided document Length 160 356 mm 6 3 14 0 inch Width 139 216 mm 5 5 8 5 inch Scanning Method Flat bed with CCD Resolution G3 8 x 3 85 lines mm Standard 8 x 7 7 lines mm Detail 8 x 15 4 line mm Fine 200 x 100 dpi Standard 200 x 200 dpi Detail Transmission Time G3 3 at 28 8Kbps Measured with G3 ECM using memory for an ITU T 1 test document Slerexe letter at standard resolution Data Compression MH MR...

Страница 239: ...cal area network Ethernet 100base Tx 10base T IEEE1394 IP over 1394 IEEE802 11b wireless LAN Resolution Main scan 400 dpi 200 dpi Sub scan 400 dpi 200 dpi 100 dpi To use 400 dpi IFAX SW01 Bit 4 must be set to 1 Transmission Time 1 s through a LAN to the server Condition ITU T 1 test document Selerexe Letter MTF correction OFF TTI None Resolution 200 x 100 dpi Communication speed 10 Mbps Correspond...

Страница 240: ...MTP TCP IP Reception POP3 SMTP IMAP4 TCP IP Data Rate 100 Mbps 100base Tx 10 Mbps 10base T Authentication Method SMTP AUTH POP before SMTP A POP Remark The machine must be set up as an e mail client before installation Any client PCs connected to the machine through a LAN must also be e mail clients or some features will not work e g Autorouting ...

Страница 241: ...ndard A3 297mm x 432mm Irregular 297mm x 1200mm Transmission protocol Recommended T 38 Annex protocol TCP UDP IP communication Compatible machines IP Fax compatible machines IP Fax transmission function Specify IP address and send fax to an IP Fax compatible fax through a network Also capable of sending fax from a G3 fax connected to the public telephone lines via a VoIP gateway IP Fax reception f...

Страница 242: ...6 mm Length 139 mm to 1260 mm Custom Duplex Width 139 mm to 216 mm Length 160 mm to 356 1 mm 1 When you use 310 mm or more originals originals weighing 55k 17 lb 64 g m2 or less cannot be used in duplex scanning mode Original Weight 52 128 g m2 Table Capacity 50 sheets 80 g m2 21 lb 20 sheets 80 g m2 21 lb Original Standard Position Center Separation Friction pad method Transport Roller transport ...

Страница 243: ... lb x 1 tray Paper Feed System Feed roller and friction pad Power Source 24 Vdc and 5 Vdc from copier If optional tray heater is installed the copier also supplies Vac 120 Vac or 220 240 Vac Power Consumption Maximum 15 W excluding optional tray heater Average 14 W excluding optional tray heater Weight Not above 6 kg 13 2 lb Size W x D x H 430 x 414 x 140 mm 16 9 x 16 3 x 5 5 2 units can be instal...

Страница 244: ...r Size W x L Book ARDF Simpl Dupl A3 SEF 297 x 420 mm B4 SEF 257 x 364 mm A4 SEF 210 x 297 mm X X X A4 LEF 297 x 210 mm B5 SEF 182 x 257 mm X X X B5 LEF 257 x 182 mm A5 SEF 148 x 210 mm X X X A5 LEF 210 x 148 mm X X B6 SEF 128 x 182 mm B6 LEF 182 x 128 mm A6 SEF 105 x 148 mm 8K SEF 267 x 390 mm 16K SEF 195 x 267 mm X X X 16K LEF 267 x 195 mm DLT SEF 11 0 x 17 0 LG SEF 8 5 x 14 0 X 1 X X 2 LT SEF 8...

Страница 245: ...cap SEF 8 5 x 13 0 X 1 X X 2 Folio SEF 8 25 x 13 0 X 1 X X 2 Government 8 25 x 14 X 1 X X 2 USB4 SEF 10 0 x 14 0 Eng Quarto SEF 8 0 x 10 0 X X 2 Eng Quarto LEF 10 0 x 8 0 Custom Width 139 216 mm Length 139 356 mm X 3 X 2 4 Symbol meanings X Can use Cannot use 1 Can be used when the ARDF is installed 2 55k 17 lb 64 g m2 or less original cannot be used 3 Width 139 216 mm Length 139 1260 mm 4 Width 1...

Страница 246: ...s Duplex Optional PFU A3 SEF 297 x 420 mm B4 SEF 257 x 364 mm A4 SEF 210 x 297 mm X X X X A4 LEF 297 x 210 mm B5 SEF 182 x 257 mm X X X B5 LEF 257 x 182 mm A5 SEF 148 x 210 mm X A5 LEF 210 x 148 mm X X B6 SEF 128 x 182 mm B6 LEF 182 x 128 mm A6 SEF 105 x 148 mm 8K SEF 267 x 390 mm 16K SEF 195 x 267 mm X X X 16K LEF 267 x 195 mm DLT SEF 11 0 x 17 0 LG SEF 8 5 x 14 0 X X X LT SEF 8 5 x 11 0 X X X X ...

Страница 247: ... 8 5 x 5 5 X X F GL F4 SEF 8 0 x 13 0 X Foolscap SEF 8 5 x 13 0 X X X Folio SEF 8 25 x 13 0 X X X Government 8 25 x 14 X X X Com 10 SEF 4 124 x 9 5 X Monarch SEF 3 875 x 7 5 X C5 162 x 229 mm X C6 114 x 162 mm X DL Env 110 x 220 mm X Custom Leading edge 90 216 mm Side edge 139 356 mm X Symbol meanings X Can transport Cannot transport ...

Страница 248: ......

Страница 249: ...APPENDIX PREVENTIVE MAINTENANCE TABLES REVISION HISTORY Page Date Added Updated New None ...

Страница 250: ......

Страница 251: ... doing maintenance work Key AN As necessary C Clean Inspect R Replace Every 45k Every 90k Every 120k AN NOTE OPTICS Reflector C Air using clean DO NOT clean with dry cloth 1st 5th Mirror C Clean with dry optical cleaning cloth Platen cover C C Dry cloth Exposure glass C C Ricoh contact glass cleaner Dry cloth DRUM AREA PCU R Clean toner bottle holder Transfer roller R Discharge plate R ...

Страница 252: ... Water or alcohol Friction pad R C Dry cloth Bottom plate pad C C Water or alcohol Registration roller C C Water or alcohol FUSING UNIT Hot roller R Pressure roller R Hot roller bearings R R Pressure roller bushings C R Inlet guide C C Clean attached toner Outlet guide C C Hot roller stripper pawls C C Thermistor C C ...

Страница 253: ...N NOTE ARDF ADF Separation Pad C Dry cloth Pick up roller C Damp cloth Feed roller C Damp cloth Torque Limiter C TBA Every 45k Every 90k AN NOTE PAPER TRAY UNIT Registration roller C Water or alcohol Paper feed roller R Water or alcohol Friction pad R Dry cloth Bottom plate pad C Water or alcohol ...

Страница 254: ......

Страница 255: ...APPENDIX SP MODE TABLES REVISION HISTORY Page Date Added Updated New 56 08 24 2012 Added SP5747 204 and 205 ...

Страница 256: ......

Страница 257: ...0 to 9 0 0 0 0 1 mm step 1002 1 1st Tray Adjusts the side to side registration Adjusting Copy Image Area in the section Replacement and Adjustment SP1 002 001 is applied to all trays SP1 002 002 003 and 005 adjusts the difference from SP1 002 001 1002 2 2nd Tray 1002 3 3rd Tray 1002 4 By pass 1002 5 Duplex Adjusts the side to side registration of the 2nd side in duplex copying The 1st side is adju...

Страница 258: ... of the hot roller 1105 1 Roller Center Plain1 120 to 200 140 1 C step 1105 3 Roller Center Plain2 1105 5 Roller Center M Thick 120 to 200 145 1 C step 1105 7 Thick Paper Roller Center 0 to 40 10 1 C step Sets the additional temperature to SP1105 001 s degree for thick paper print i e SP1105 001 140 This SP 10 140 10 150 degree 1105 9 Center Minus Thin 0 to 20 5 1 C step Sets the subtractive tempe...

Страница 259: ...5 1 C step Sets the additional degree for each paper type printing under low temperature environment Refer to SP1105 015 about the environment judge 1105 17 Low Plain2 1105 18 Low M Thick 1105 19 Low Thick 0 to 30 10 1 C step The same function as SP1105 017 to 18 1105 20 Registration Waiting Plain1 0 to 1 1 1 step 0 OFF 1 ON Registration waiting means keeping fed paper in the registration part unt...

Страница 260: ...k 1105 38 Waiting Center Upper Thick 1106 Fusing Temperature Display 1106 1 Roller Center 20 to 250 0 1 C step 1106 3 In The Machine at Power On 20 to 250 0 1 C step Displays the thermistor temp at power on 1108 Control Period Setting 1108 1 Warming up 100 to 2000 100 100 msec step 1108 2 Print 100 to 2000 1000 100 msec step 1108 3 Wait 100 to 2000 1000 100 msec step 1108 4 Print Start 100 to 2000...

Страница 261: ...step The same function as 003 004 1124 6 High 1st CPM 10 to 100 65 1 step Sets the rate for CPM down High Temp 1124 7 High 2nd CPM 10 to 100 50 1 step The same function as 006 008 1124 8 High 3rd CPM 10 to 100 50 1 step The same function as 006 007 1124 9 High 1st CPM Down Time LT 0 to 999 0 1 sec step After motor driving start CPM High temp gets one step down in SP s value sec later for each pape...

Страница 262: ... 60 1 sec step 1124 22 High 2nd CPM Down Time A6 0 to 999 1 1 sec step 1124 23 High 3rd CPM Down Time A6 0 to 999 0 1 sec step 1124 24 Judging Interval 1 to 999 10 1 sec step For CPM down Low temp 1124 25 Start Timing 1 to 999 10 1 sec step After motor driving start CPM down judge starts in SP s value sec later Low temp 1152 Fusing Nip Band Check By pass 1152 1 Check By pass Execution type SP 1152...

Страница 263: ...y the zero cross signal generator 1907 Paper Pre Feed Timing 1907 20 F2 Tray 10 to 10 0 1 mm step The larger value set the larger area of the paper is pre fed for each tray 1907 21 F3 Tray 1907 22 F2 Tray 1907 23 F3 Tray 1950 Fan Cooling Time Set 1950 1 Fusing Exit Fan 0 to 900 10 1 sec step Sets the duration of the fusing exit fun on waiting and abnormal condition 1951 Fan start Time Set 1951 1 F...

Страница 264: ...ndix 1991 Max Fusing Lamp Duty 1991 1 Roller Center 40 to 100 100 10 step 1991 3 After Warming Up Center 1996 Heater Forced Off 1996 5 After Printing 0 to 120 7 1 sec step Sets the wait time before the heater will be forced off after printing ...

Страница 265: ...f charge roller voltage correction Setting the same value as SP2 201 002 is preferable 2001 3 Temporally Input 2500 to 0 0 10 V step Inputs the voltage value Too small value may cause the charge roller tainted Too large value may cause attaching carrier particles in developer on a printed paper The value from 1800 V to 1600 V is preferable 2005 Charge Bias Correction 2005 1 Vsdp Min 0 to 100 90 1 ...

Страница 266: ...03 Erase Margin Adj 2103 1 Leading Edge 0 to 4 3 0 1 mm step 2103 2 Trailing Edge 2103 3 Left 0 to 4 2 0 1 mm step 2103 4 Right 2104 Unit LD Power Adj 2104 1 LD1 60 to 140 100 0 1 step 2104 2 LD2 2105 LD Power Adjustment 2105 1 60 to 140 100 0 1 step ...

Страница 267: ...nd s Tooth Check Vertical 4 Horizontal Line 2dot 17 Black Band Horizontal 5 Grid Vertical Line 18 Black Band vertical 6 Grid Horizontal Line 19 Checker Flag Pattern 7 Grid Pattern Small 20 Grayscale Vertical 8 Grid Pattern Large 21 Grayscale Horizontal 9 Argyle Pattern Small 22 Two Beam Density Pattern 10 Argyle Pattern Large 23 Full Dot Pattern 11 Independent Pattern 1dot 24 All White pattern 12 ...

Страница 268: ...86 3 0 1 step 2152 8 LD1 Area 7 75 to 125 88 2 0 1 step 2152 9 LD1 Area 8 75 to 125 89 9 0 1 step 2152 10 LD1 Area 9 75 to 125 91 5 0 1 step 2152 11 LD1 Area 10 75 to 125 93 0 1 step 2152 12 LD1 Area 11 75 to 125 94 3 0 1 step 2152 13 LD1 Area 12 75 to 125 95 5 0 1 step 2152 14 LD1 Area 13 75 to 125 96 6 0 1 step 2152 15 LD1 Area 14 75 to 125 97 5 0 1 step 2152 16 LD1 Area 15 75 to 125 98 3 0 1 st...

Страница 269: ...125 97 0 1 step 2152 30 LD1 Area 29 75 to 125 96 0 1 step 2152 31 LD1 Area 30 75 to 125 94 8 0 1 step 2152 32 LD1 Area 31 75 to 125 93 5 0 1 step 2152 33 LD2 Area 0 75 to 125 100 0 1 step 2152 34 LD2 Area 1 75 to 125 82 0 1 step 2152 35 LD2 Area 2 75 to 125 82 0 1 step 2152 36 LD2 Area 3 75 to 125 82 0 1 step 2152 37 LD2 Area 4 75 to 125 84 0 1 step 2152 38 LD2 Area 5 75 to 125 85 8 0 1 step 2152 ...

Страница 270: ...1 0 1 step 2152 52 LD2 Area 19 75 to 125 100 4 0 1 step 2152 53 LD2 Area 20 75 to 125 100 6 0 1 step 2152 54 LD2 Area 21 75 to 125 100 8 0 1 step 2152 55 LD2 Area 22 75 to 125 100 8 0 1 step 2152 56 LD2 Area 23 75 to 125 100 7 0 1 step 2152 57 LD2 Area 24 75 to 125 100 5 0 1 step 2152 58 LD2 Area 25 75 to 125 100 2 0 1 step 2152 59 LD2 Area 26 75 to 125 99 8 0 1 step 2152 60 LD2 Area 27 75 to 125 ...

Страница 271: ...H 2 L 3 HH 4 LL 0 to 4 0 1 step Adjusts the toner density control of the developer case 0 Normal 1 Thick 2 Thin 3 More thick 4 More thin 2201 3 ID sensor pattern Temporally Input 700 to 300 420 10 V step 2210 Bias Off Time 2210 1 Charge Bias 10 to 150 100 10 step 2210 2 Development Bias 10 to 200 80 10 step 2211 PCU Reverse Interval 0 to 999 100 1 sheet step 2211 1 This value affects how many shee...

Страница 272: ...nsfer Current Adjust Adjusts the current applied to the transfer roller 2301 1 Thin 1side Image Area 0 to 4 0 1 step Each value suggests as follows 0 2 A Default 1 0 A 2 2 A 3 4 A 2301 2 Thin 1side Lead Edge 2301 3 Thin 1side Trail Edge 2301 4 Thin 2side Image Area 2301 5 Thin 2side Lead Edge 2301 6 Thin 2side Trail Edge 2301 7 Plain 1side Image Area 2301 8 Plain 1side Lead Edge 2301 9 Plain 1side...

Страница 273: ... Edge 2301 22 Input 1side 0 to 30 0 1 A step 2301 23 Input 2side 2301 25 Temp Inside the Machine 25 to 55 20 1 A step This temp affects transfer current value 2301 26 Non Image Area LL 0 to 30 10 1 A step Output current under low temperature condition Refer to SP1105 015 about the condition judge 2301 27 Non Image Area MM 0 to 30 13 1 A step Output current under normal temperature condition Refer ...

Страница 274: ...miter 2308 1 0 OFF 1 ON The switch of the limiter for transfer voltage 2801 Developer Initialization 2801 1 Execute in the case of PCU replacement 2802 Developer Mixing 2802 1 Initializes the developer and checks the TD sensor output Vt The machine mixes the developer for 2 minutes while reading and displaying the Vt value The machine does not initialize the TD sensor output If the machine has not...

Страница 275: ... 5 Switching Timing Lead Edge 20 to 20 15 1 mm step 2906 Tailing Control 2906 1 Shift Range 0 0 to 1 0 0 0 0 1 mm step Shifts the image position When the copier is continuously printing vertical lines such as in tables the paper may not separate correctly This SP can prevent this 2906 2 Number of Sheets 1 to 10 1 1 sheet step Changes the number of sheet s under tailing control with the shift range...

Страница 276: ...ply Time 0 1 to 5 0 0 5 0 1 sec step 2922 1 Adjusts the toner supply time The toner supply motor remains on for the specified time Specify a greater value if the user tends to make many copies having high proportions of solid black image areas 2923 Toner Recovery Time 1 to 60 30 1 sec step 2923 1 Adjusts the toner supply time under the condition of Toner End or Toner Near End detected 2925 Toner S...

Страница 277: ...ner end message Copies After Toner Near End Counter SP2 224 001 Do not use this SP in usual operations When the toner in the development unit is abnormally insufficient the drum may attract the toner carrier to its surface The toner carrier damages the drum surface 2929 Vref Adjustment Adjust the upper or lower Vref limit 2929 1 Upper Limit 0 50 to 3 50 2 40 0 05 V step DFU 2929 2 Lower Limit 0 50...

Страница 278: ...MW Setting 2934 1 Dilay 0 to 1023 200 1 step 2934 2 Upper Limit Correction 0 to 1023 100 1 step Sets PMW upper limit 2935 ID Sensor Initialization 2935 1 Use this SP after ID Sensor replacement This Operates PWM value clearing Vsg re adjustment and PWM re adjustment 2936 ID Sensor Detection Interval Counter 2936 1 0 to 999 0 1 page step The counter applying to SP2 995 002 2992 Copies After TD Sens...

Страница 279: ...ns or does not clean the transfer roller before each job Select 1 if the backside of the paper becomes unclean when output Note that the copier takes a longer time to output the first copy when you select 1 If you select 0 the transfer roller is never cleaned 2996 2 Interval 0 to 100 50 1 step When the SP2 996 003 counter is over this SP s value Transfer roller cleaning is activated on the Job End...

Страница 280: ...placement and Adjustment 4011 S to S Regist Adjustment 2 0 to 2 0 0 0 0 1 mm step 4011 1 Adjusts the side to side registration for scanning in platen mode Adjusting Copy Image Area in the section Replacement and Adjustment 4012 Scan Erase Margin Scale 0 to 3 0 0 0 0 1 mm step 4012 1 Book Leading Edge Adjusts the scanning margin Generally the scanning margin should be as little as possible 4012 2 B...

Страница 281: ...able FC 600 dpi 4014 4 HP Detection Enable BW 600 dpi 4014 5 HP Detection Enable FC 1200dpi 4016 DF Scan 4016 1 FC 600x300 Duplex 4016 2 BW 600x300 Duplex 4016 3 FC 600x600 Duplex 4016 4 BW 600x600 Duplex 4016 5 FC 600x200 Duplex 4016 6 FC 600x300 Simplex 4016 7 BW 600x300 Simplex 4016 8 FC 600x600 Simplex 4016 9 BW 600x600 Simplex 4016 10 FC 600x200 Simplex ...

Страница 282: ... the detection becomes 4020 3 Dust Reject Lvl 0 to 4 0 1 step 0 OFF The larger value is set the stronger the correction becomes 4400 Scanner Erase Margin 0 to 3 0 0 1 mm step 4400 1 Book Leading Edge Adjusts the mask range against shade on each part of the original 4400 2 Book Trailing Edge 4400 3 Book Left 4400 4 Book Right 4400 5 Trailing Edge Adjusts the mask range for ADF copying 4400 7 Left 4...

Страница 283: ... 1 20 Scanned Grid pattern 6 Grid pattern 1 21 None 7 Slant grid pattern 22 Scanned Color patch 8 Gradation K 23 Scanned Slant Grid C 9 None 24 None 10 Gray patch 16 1 25 Gray scale 18 text 11 Gray patch 16 2 26 Gray scale 18 photo 12 Gray patch 64 27 Gray scale 256 text 13 Grid pattern 2 28 Gray scale 256 photo 14 Color patch K 4429 Select Copy Data Security 0 to 3 3 1 step 4429 1 Copying The lar...

Страница 284: ...et area background 4460 2 Background level 512 to 1535 932 1 step 4550 Scan Apli Txt Print These SPs have the same lower level settings as below 4551 Scan Application Txt 4552 Scan Application Txt Dropout 4553 Scan Application Txt Photo 4554 Scan Application Photo 4565 Scan Application GrayScale 4570 Scan Application Color Txt Photo 4571 Scan Application Color Gloss Photo 4572 Scan Application Aut...

Страница 285: ...elow SP4581 4584 4585 don t have 010 4581 Fax Application Txt 4582 Fax Application Txt Photo 4583 Fax Application Photo 4584 Fax Application Original 1 4585 Fax Application Original 2 005 MTF 0 to 15 8 1 step 0 Off 1 15 Weak Strong 006 Smoothing 0 to 7 4 1 step 0 x1 1 7 Weak Strong 007 Brightness 1 to 255 128 1 step 008 Contrast 009 Ind Dot Erase Independent Dot Erase 0 to 7 0 1 step 0 Off 1 7 Wea...

Страница 286: ...4606 1 Color 600 0 to 1024 784 1 digit step 4607 White Level Adjust 4607 1 Color 1200 0 to 1024 784 1 digit step 4608 White Level Adjust 4608 1 BK 0 to 1024 784 1 digit step 4609 Gray Balance Set R 4609 1 Book Scan 512 to 511 89 1 digit step 4609 2 DF Scan 4610 Gray Balance Set G 4610 1 Book Scan 512 to 511 76 1 digit step 4610 2 DF Scan 4610 3 BW Book Scan 512 to 511 92 1 digit step 4610 4 BW DF ...

Страница 287: ...600 0 to 255 0 1 digit step 4623 2 Latest R Color 1200 4624 Black Level Adj Display 4624 1 Latest G Color 600 0 to 255 0 1 digit step 4624 2 Latest G Color 1200 4624 1 Latest BK E 4624 2 Latest BK O 4625 Black Level Adj Display 4625 1 Latest B Color 600 0 to 255 0 1 digit step 4625 2 Latest B Color 1200 4631 Display Gain Adjust 4631 1 Latest R Color 600 0 to 511 0 1 digit step 4631 2 Latest R Colo...

Страница 288: ...est BK O 4633 Display Gain Adjust 4633 1 Latest B Color 600 0 to 511 0 1 digit step 4633 2 Latest B Color 1200 4645 Scan Adjust Error 4645 1 White level 0 to 65535 0 1 step 4645 2 Black level 4647 Scanner Hard Error 4647 1 Power ON 0 to 65535 0 1 step 4654 Black Level Adj Display 4654 1 Last Correct Value R Color 600 0 to 255 0 1 digit step 4654 2 Last Correct Value R Color1200 ...

Страница 289: ...lue B Color 600 0 to 255 0 1 digit step 4656 2 Last Correct Value B Color1200 4661 Digital Gain Adjust 4661 1 Last Correct Value R Color 600 0 to 511 0 1 digit step 4661 2 Last Correct Value R Color1200 4662 Digital Gain Adjust 4662 1 Last Correct Value G Color 600 0 to 511 0 1 digit step 4662 2 Last Correct Value G Color1200 4662 3 Last Correct Value BK E 4662 4 Last Correct Value BK O 4663 Digit...

Страница 290: ...Color1200 4674 3 Factory Setting BK E 4674 4 Factory Setting BK O 4675 Black Level Adj Display 4675 1 Factory Setting B Color 600 0 to 255 0 1 digit step 4675 2 Factory Setting B Color1200 4680 Digital Gain Adjust 4680 1 Factory setting R Color 600 0 to 511 0 1 digit step 4680 2 Factory setting R Color1200 4681 Digital Gain Adjust 4681 1 Factory setting G Color 600 0 to 511 0 1 digit step 4681 2 F...

Страница 291: ...ensity 50 to 150 100 1 step 4690 White Level Peak Read R 4690 1 R Color 600 0 to 1023 0 1 digit step 4690 2 R Color1200 4691 White Level Peak Read G 4691 1 G Color 600 0 to 1023 0 1 digit step 4691 2 G Color1200 4691 3 BK E 4691 4 BK O 4692 White Level Peak Read B 4692 1 B Color 600 0 to 1023 0 1 digit step 4692 2 B Color1200 4693 Black Level Peak Read R 4693 1 R Color 600 0 to 1023 0 1 digit step...

Страница 292: ... 4694 4 BK O 4695 Black Level Peak Read B 4695 1 B Color 600 0 to 1023 0 1 digit step 4695 2 B Color1200 4802 DF Shading FreeRun 4802 1 Lamp OFF 0 OFF 1 ON 4802 2 Lamp ON 4804 Home Position 4804 1 Home Position Execution type SP 4806 Carriage Save 4806 1 Carriage Save Execution type SP 4808 Factory Setting Input 4808 2 Execution Flag 0 to 1 0 1 step ...

Страница 293: ...step 4810 5 Last Correct Value Color 1200 4810 6 Last Correct Value Bk 4810 7 Factory Setting Color 600 0 to 4412 0 1 digit step 4810 8 Factory Setting Color 1200 4810 9 Factory Setting Bk 4811 LED White Level Peak Read 4811 1 Latest R Color 600 0 to 1023 0 1 digit step 4811 2 Latest R Color 1200 4811 3 Latest G Color 600 4811 4 Latest G Color 1200 4811 5 Latest BkE 4811 6 Latest BkO 4811 7 Latest...

Страница 294: ...tory Setting BkO 4812 7 Factory Setting B Color 600 4812 8 Factory Setting B Color 1200 4813 LED White Level Adjust 4813 1 Color 600 0 to 1023 784 1 digit step 4813 2 Color 1200 4813 3 Bk 0 to 1023 540 1 digit step 4903 Filter Setting 4903 1 Ind Dot Erase Text 0 to 7 0 1 digit step Independent Dot Erase 4903 2 Ind Dot Erase Generation Copy 4905 Select Gradation Level 0 to 255 0 1 step 4905 1 Adjus...

Страница 295: ...9 6 Option Middle 0 to 12 0 1 step 4909 7 Option Shadow 0 to 255 0 1 step 4909 8 Option IDmax 0 to 255 0 1 step 4914 Man Gamma T ColK 4914 1 Offset Highlight 0 to 30 15 1 step 4914 2 Offset Middle 4914 3 Offset Shadow 4914 4 Offset IDmax 4914 5 Option Highlight 0 to 255 0 1 step 4914 6 Option Middle 0 to 12 0 1 step 4914 7 Option Shadow 0 to 255 0 1 step 4914 8 Option IDmax 0 to 255 0 1 step 4918 ...

Страница 296: ...5 0 1 step 4991 IPU Image Pass Selection 4991 1 RGB Frame Memory single 0 to 11 2 1 step 4993 High Light Correction 4993 1 Sensitivity Selection 0 to 9 4 1 step 4993 2 Range Selection 4994 Text Photo Detect Level Adj 4994 1 High Compression PDF 0 to 2 1 1 step 4996 White Paper Detect Level 0 to 6 3 1 step 4996 1 Dull 0 6 Sensitive Adjusts the degree of white paper detection sensitivity ...

Страница 297: ... 1 inch American model 0 mm 1 inch 5045 Accounting Counter 5045 1 Counter Method Displays the number of the installed counter 0 to 2 0 1 step 0 1 counter Total 1 2 counters Total and Prints 2 2 counters GPC 5047 Paper Display 001 Backing Paper 0 OFF 1 ON Sets the backing paper button display ON OFF on paper size selection 5055 Display IP address 001 Display IP address CTL Displays or does not disp...

Страница 298: ...splay 1 Display 5112 Non Std Paper Sel 0 OFF 1 ON 5112 1 Sets Non standard size setting in usual panel operations available or not 5113 Optional Counter Type 001 Default Optional Counter Type CTL This program specifies the counter type 0 None 1 Key card RK 3 4 2 Key card down 3 to 10 Japan only 11 Exp Key card Add 12 Exp Key card Deduct 002 External Optional Counter Type CTL This program specifies...

Страница 299: ...ettings when the key counter is removed 0 Y Yes The settings are cleared when the counter is removed 1 StdBy Standby only The settings are cleared when the counter is removed at the end of a job 2 N No The settings are not cleared under either condition As for duplex copying the job settings are always preserved regardless of these setting 5121 Counter Up Timing 0 Feed In 1 Exit 5121 1 Selects the...

Страница 300: ...atic printing 5169 CE Login If you change the printer bit switches you must log in to service mode with this SP before you go into the printer SP mode 001 CE Login CTL 0 or 1 0 0 Disabled 1 Enabled 5186 RK4 Setting 0 or 1 0 5186 1 1 Jam 0 None in 10 sec after put the card out 5188 Copy NV Version 001 Copy NV Version CTL Displays the NVRAM version in the controller board 5195 Limitless SW 0 or 1 0 ...

Страница 301: ...004 Duplex Printout High Low Position Vertically positions the page numbers printed on both sides during duplexing 10 to 10 0 1 mm 0 is center minus is down is up 5302 Set Time Adjusts the RTC real time clock time setting for the local time zone Examples For Japan 9 GMT enter 540 9 hours x 60 min DOM 540 Tokyo NA 300 New York EU 60 Paris CH 480 Peking TW 480 Taipei AS 480 Hong Kong 002 Time Differ...

Страница 302: ...he month 1 to 5 4th digit The day of the week 0 to 6 Sunday to Saturday 5th and 6th digits The hour 00 to 23 7th digit The length of the advanced time 0 to 9 1 hour step 8th digit The length of the advanced time 0 to 5 10 minutes step For example 3500010 EU default The timer is advanced by 1 hour at am 0 00 on the 5th Sunday in March The digits are counted from the left Make sure that SP5 307 1 is...

Страница 303: ...Method CTL 210 SDK2 Unique ID CTL 211 SDK2 Certification Method CTL 220 SDK3 Unique ID CTL 221 SDK3 Certification Method CTL 240 Detail Option CTL Enables or disables the log out confirmation option Bit0 Log out confirmation option 0 Enable default 1 Disable Selects the automatic log out time Bit1 and 2 Automatic log out timer reduction 00 60 seconds default 01 10 seconds 10 20seconds 11 30 second...

Страница 304: ... is referenced only when SP5411 4 is set to 1 On 0 to 1 0 1 0 Password NULL not permitted 1 Password NULL permitted 006 Detail Option Bit 0 Anonymous authorization 0 OFF 1 ON Only bit 0 is used 5413 Lockout Setting 001 Lockout On Off Switches on off the lock on the local address book account 0 to 1 0 1 0 Off 1 On 002 Lockout Threshold Sets a limit on the frequency of lockouts for account lockouts ...

Страница 305: ...user ID and password are entered 004 Cancellation Time Determines the length of time that the system waits for correct input of the user ID and password after a lockout has occurred This setting is used only if SP5413 3 is set to 1 on 1 to 999 60 1 min 5414 Access Mitigation 001 Mitigation On Off Switches on off masking of continuously used IDs and passwords that are identical 0 to 1 0 1 0 Off 1 O...

Страница 306: ... such an attack has been detected 1 to 10 5 1 sec 5416 Access Information 001 Access User Max Num Limits the number of users used by the access exclusion and password attack detection functions 50 to 200 200 1 users 002 Access Password Max Num Limits the number of passwords used by the access exclusion and password attack detection functions 50 to 200 200 1 passwords 003 Monitor Interval Sets the ...

Страница 307: ... the speed of certification when an excessive number of access attempts have been detected 0 to 9 3 1 sec 004 Attack Max Num Sets a limit on the number of requests received for certification in order to slow down the certification speed when an excessive number of access attempts have been detected 50 to 200 200 1 attempt 5420 User Authentication These settings should be done with the System Admin...

Страница 308: ...user can use the fax application 0 to 1 0 1 0 On 1 Off 031 Scanner Determines whether certification is required before a user can use the scan applications 0 to 1 0 1 0 On 1 Off 041 Printer Determines whether certification is required before a user can use the printer applications 0 to 1 0 1 0 On 1 Off 051 SDK1 0 or 1 0 1 0 ON 1 OFF Determines whether certification is required before a user can us...

Страница 309: ...s whether an error code appears on the operation panel after a user authentication failure occurs 0 to 1 1 1 1 On 0 Off 5507 Supply Alarm CTL 080 Toner Call Timing 0 Toner is replaced default 1 Toner near end or end 5508 CC Call CTL 001 Jam Remains 0 Disable 1 Enable Enables disables initiating a call for an unattended paper jam 002 Continuous Jams 0 Disable 1 Enable Enables disables initiating a ...

Страница 310: ...error occurs 001 SC Call 0 or 1 1 0 Off 1 On 002 Service Parts Near End Call 003 Service Parts End Call 004 User Call 006 Communication Test Call 007 Machine Information Notice 008 Alarm Notice 010 Supply Automatic Ordering call 0 or 1 1 0 Off 1 On 011 Supply Management Report call 012 Jam Door Open Call 0 or 1 1 0 Off 1 On 5730 Extended Function Setting 010 Expiration Prior Alarm Set DFU 5741 Nod...

Страница 311: ... User Agent 031 Use Java Script 032 Use Extended Java Script 041 Keep History 042 History Period 051 Use Proxy 052 Proxy Server Name 053 Proxy Port 054 Proxy User Name 055 Proxy Password 056 Hosts Not Using Proxy 061 Accept cookie 071 Show URL Bar 072 Show Horizontal Scroll 081 Homepage 181 User Permit Homepage 182 User Permit Bookmark 183 User Permit Proxy 184 User Permit History ...

Страница 312: ...ge confirmation dialog SSL certificate confirmation dialog 0 Default Display Display 1 Not display Display 2 Not Display Not display 3 Display Not display 206 Displayed but it should not be used Not for field use 5793 ECS Debug SW DFU 5794 Browser Debug DFU 5801 Memory Clear Before executing any of these SP codes print an SMC Report 001 All Clear Initializes items SP5801 002 to 014 below Turn the ...

Страница 313: ...s the NCS Net Control Service settings 012 R FAX Initializes the job login ID SmartNetMonitor for Admin job history and local storage file numbers 014 Clear DCS Setting Initializes the DCS Delivery Control Service settings 015 Clear VCS Setting Initializes the UCS User Information Control Service settings 017 CCS Initializes the CCS Certification and Charge control Service settings 018 SRM Memory ...

Страница 314: ...5 Websys Initialization applying to the following SPs SP5 885 020 SP5 885 050 SP5 885 051 SP5 885 100 SP5 885 101 SP5 885 200 SP5 885 201 5803 Input Check Input Check in this chapter 5804 Output Check Output Check in this chapter 5810 SC Reset 001 Fusing SC Reset Resets SC of CE Reset 5811 Machine Serial 002 Display Machine No Setting in this section ...

Страница 315: ...2 Facsimile CTL Sets the fax or telephone number for a service representative This number is printed on the Counter List This can be up to 20 characters both numbers and alphabetic characters can be input 003 Supply CTL Use this to input the telephone number of your supplier for consumables Enter the number and press StringIn key Press the Clear modes key to delete the telephone number 004 Operati...

Страница 316: ...ateway Use this SP to set up or display the customer proxy server address The address is necessary to set up embedded RCG N The address display is limited to 127 characters Characters beyond the 127th character are ignored This address is customer information and is not printed in the SMC report 064 Proxy Port Number This SP sets the port number of the proxy server used for communication between e...

Страница 317: ...ength of the password is limited to 31 characters Any character beyond the 31st character is ignored This name is customer information and is not printed in the SMC report 250 CommLog Print Prints the communication log 5824 NVRAM Upload 5824 1 NVRAM Upload Download in this section 5825 NVRAM Download 5825 1 NVRAM Upload Download in this section 5828 Network Setting CTL 001 IPv4 Address Ethernet IE...

Страница 318: ...000 000 050 1284 Compatibility Centro 0 Not permitted 1 Permitted 052 ECP Centro 0 Not permitted 1 Permitted 065 Job Spooling Enables disables Job Spooling 0 or 1 0 1 step 0 Disable 1 Enable 066 Job Spooling clear start time Determines whether spooled job in the HDD is cleared or printed on machine start up 0 Clear 1 Print 069 Job Spooling Protocol Validates or invalidates the job spooling functio...

Страница 319: ...n to NCP 5 AppleTalk 21 Reserve 6 DHCP 22 Bluetooth 7 DHCPv6 23 IEEE 1284 8 telnet 24 USB print 9 SSL 25 Dynamic DNS 10 HTTPS 26 Netware print 11 BMLinks print 27 LLTD 12 diprint printing 28 IPP print 13 LPR print 29 IPP print SSL 14 ftp print 30 ssh 15 rsh print 31 sftp 090 TELNET 0 OFF 1 ON Enables or disables the TELENET 091 Web 0 OFF 1 ON Enables or disables the Web operation 0 or 1 1 0 Disabl...

Страница 320: ...IPv6 Manual Address 158 IPv6 Gateway Address 161 IPv6 Stateless Auto Setting Enables or disables the function 0 Disable 1 Enable 236 Web Item Invisible Determines whether each item can be set in Websys 0x0000 to 0xffff 0xffff Bit 1 NetRICOH Bit2 Vendor for consumables Bit2 15 Reserved Web Shopping Link Invisible Determines whether the NetRICOH link is displayed on the Websys top page and link page...

Страница 321: ...e 1 Visible 249 DHCPv6 DUID 5832 HDD Enter the SP number for the partition to initialize then press Execute When the execution ends cycle the machine off and on 001 HDD Formatting All 002 HDD Formatting IMH 003 HDD Formatting Thumbnail 004 HDD Formatting Job Log 005 HDD Formatting Printer Fonts 006 HDD Formatting User Info 007 Mail Rx Data 008 Mail Tx Data 009 HDD Formatting Data for a Design 010 ...

Страница 322: ...B W Other 075 Reduction for Printer B W 082 Format for Copy B W Text 0 to 3 1 1 step These SPs are valid only when MLB is equipped Each of the following values represents 0 JFIF JPEG 1 TIFF MMR 2 TIFF MH 3 TIFF MR 083 Format for Copy B W Other 085 Format for Printer B W 091 Default for JPEG 5 to 95 50 1 step 101 Primary srv IP address 000 000 000 000 to 255 255 255 255 Default 000 000 000 000 Sets...

Страница 323: ...determined automatically on CS I O device registration 113 Secondary srv port number 1 to 65535 80 1 step Normally the value is determined automatically on CS I O device registration 114 Secondary srv URL path 0 to 16 letter s Normally the value is determined automatically on CS I O device registration 120 Default Reso Rate Switch 0 or 1 0 1 step Normally the value is determined automatically on C...

Страница 324: ...cification limit output is done by the nearest rate within the limitation Value Resolution 0 600dpi 1 400dpi 2 300dpi 3 200dpi 4 150dpi 5 100dpi 6 75dpi 126 Reso Fax Mono 0 to 255 3 1 step The value affects the resolution applying to capturing a monochrome original read by Fax application See the list below Normally the value is determined automatically on CS I O device registration When the resol...

Страница 325: ...chine specification limit output is done by the nearest rate within the limitation Value Resolution 0 600dpi 1 400dpi 2 300dpi 3 200dpi 4 150dpi 5 100dpi 6 75dpi 128 Reso Scanner Mono 0 to 255 3 1 step The value affects the resolution applying to capturing a monochrome original read by Scanner application See the list below Normally the value is determined automatically on CS I O device registrati...

Страница 326: ...ss LAN The number of channels available varies according to location The default settings are set for the maximum end of the range for each area Adjust the upper 4 bits to set the maximum number of channels DFU Do not change the setting 007 Channel MIN CTL 1 to 11 or 13 1 1 step Europe 1 to 13 NA Asia 1 to 11 Sets the minimum number of channels available for data transmission via the wireless LAN ...

Страница 327: ...1 Key 4 Reserved Selects the WEP key 042 Fragment Thresh CTL 256 to 2346 2346 1 Adjusts the fragment threshold for the IEEE802 11 card This SP is displayed only when the IEEE802 11 card is installed 043 11g CTS to Self CTL 0 to 1 1 1 0 Off 1 On Determines whether the CTS self function is turned on or off This SP is displayed only when the IEEE802 11 card is installed 044 11g Slot Time CTL 0 to 1 1...

Страница 328: ... Default Bit SW 1000 0000 Bit Groups 0 System other groups LSB 1 Capture related 2 Certification related 3 Address book related 4 Machine management related 5 Output related printing delivery 6 Repository related 7 Debug log output 002 Setting 2 CTL Default Bit SW 0000 0000 Bit Groups 0 6 Not used 7 Log time stamp setting 0 Date Hour Minute Second 1 Minute Second Msecond ...

Страница 329: ...e Number CTL Sets the device release number of the BCD binary coded decimal display 0000 to 9999 1 DFU Enter as a decimal number NCS converts the number to hexadecimal number recognized as the BCD 005 Fixed USB Port 0 to 3 0 1 step Sets the control function saving driver re install ON OFF 0 OFF 1 ON Level 1 ON for the same model 2 ON Level 2 Depending on SP5844 006 007 006 PnP Model Name 20 letter...

Страница 330: ...ting to determine the length of time the prompt message is displayed when a test error occurs during document transfer with the NetFile application and an external device 008 Server IP Secondary Range 000 000 000 000 to 255 255 255 255 Specifies the IP address assigned to the computer designated to function as the secondary delivery server of Scan Router This SP allows only the setting of the IP a...

Страница 331: ...sword function exists Bit1 1 Function to link MK 1 user and Sender exists Bit0 1 Sender specification required if set to 1 Bit6 is set to 0 011 Delivery Svr Capability Ext 0 to 255 0 1 step Changes the capability of the server that is registered as an I O device Bit7 1 Address book usage limitation Limitation for each authorized user Bit6 1 RDH authorization link Bit5 to 0 Not used 013 Server Sche...

Страница 332: ...ides items for delivery server settings 001 Machine ID for Delivery Server Displays ID Displays the unique device ID in use by the delivery server directory The value is only displayed and cannot be changed This ID is created from the NIC MAC or IEEE 1394 EUI The ID is displayed as either 6 byle or 8 byte binary 002 Machine ID Clear for Delivery Server Clears ID Clears the unique ID of the device ...

Страница 333: ...quire the delivery server address book 007 Delivery Server retry Times 0 to 255 0 1 step Sets the number of retry attempts when the delivery server fails to acquire the delivery server address book 008 Delivery Server Maximum Entries 200 to 999 200 1 step Sets the maximum number account entries of the delivery server user information managed by UCS 010 LDAP Search Timeout 1 to 255 60 1 step Sets t...

Страница 334: ...formation to an SD card with SP5846 051 before you execute this SP After the address book data is copied to HDD all the address book data is deleted from the flash ROM If the operation fails the data is not erased from the flash ROM 041 Fill Adder Book A C L Info This SP must be executed immediately after installation of an HDD unit in a basic machine that previously had no HDD The first time the ...

Страница 335: ... address book information except the user code 050 Initialize All Addr Book Clears all directory information managed by UCS including all user codes Turn the main power switch off and on after executing this SP 051 Backup All Addr Book Uploads all directory information to the SD card 052 Restore All Addr Book Downloads all directory information from the SD card 053 Clear Backup Info Deletes the ad...

Страница 336: ... limits the password entry to lower case and defines the length of the password 0 to 32 0 1 step 064 Complexity Option 3 1 Use this SP to set the conditions for password entry to access the local address book Specifically this SP limits the password entry to numbers and defines the length of the password 0 to 32 0 1 step 065 Complexity Option 4 1 Use this SP to set the conditions for password entr...

Страница 337: ...s 0 x1 1 1 2 2 1 3 3 1 4 4 1 6 5 1 8 6 2 3 003 Rate for Copy B W Other 005 Rate for Printer B W 007 Rate for Printer B W 1200dpi 0 to 6 1 1 step 021 Network Quality Default for JPEG 5 to 95 50 1 step 5848 Web Service CTL SP5848 1 sets the 4 bit switch assignment for the access control setting Setting of 0001 has no effect on access and delivery from Scan Router ac Access Control 002 Access Ctrl Re...

Страница 338: ...splays the log server settings These can be adjusted with the Web Image Monitor 211 Log Type Job2 212 Log Type Access 213 Primary Server 214 Secondary Server 215 Start Time 216 Interval Time Specifies the transmit interval 1 to 1000 1 1 hour step This SP is activated only when SP5848 217 is set to 2 Transmit periodically 217 Timing Selects the transmit timing 0 to 2 0 1 step 0 No Transmit 1 Transm...

Страница 339: ...ounter when the installation date is registered to the machine 5853 Stamp Data Download Push Execute to download the fixed stamp data from the machine ROM onto the hard disk Then these stamps can be used by the system If this is not done the user will not have access to the fixed stamps Confidential Secret etc You must always execute this SP after replacing the HDD or after formatting the HDD Alwa...

Страница 340: ...for saving to an SD card 009 Copy HDD to SD Card Latest 4MB Takes the most recent 4 MB of the log written to the hard disk and copies them to the SD Card A unique file name is generated to avoid overwriting existing file names on the SD Card Up to 4MB can be copied to an SD Card 4 MB segments can be copied one by one to each SD Card 010 Copy HDD to SD Card Latest 4MB Any Key Takes the log of the s...

Страница 341: ... name is generated to avoid overwriting existing file names on the SD card Up to 4MB can be copied to the SD card 4 MB segments can be copied one by one to the SD card 015 Copy SD to SD Latest 4 MB Any Key Saves the specified debug log with SP5 857 006 in memory to the SD card A unique file name is generated to avoid overwriting existing file names on the SD card Up to 4MB can be copied to the SD ...

Страница 342: ...nerated by copier engine errors 0 or 1 0 1 step 0 OFF 1 ON 002 Controller SC Error Turns the save function on off for SC codes generated by GW controller errors 0 or 1 0 1 step 0 OFF 1 ON 003 Any SC Error 0 to 65535 0 1 step 004 Jam Turns the save function on off for jam errors 0 or 1 0 1 step 0 OFF 1 ON 5859 Debug Save Key No CTL 001 Key 1 These SPs allow you to set up to 10 keys for log files fo...

Страница 343: ...itched on for MDN reply mail 0 No 1 Yes 022 SMTP Auth From Field Replacement 0 to 1 0 Determines whether the FROM item of the mail header is switched to the validated account after the SMTP server is validated 0 No From item not switched 1 Yes From item switched 025 SMTP Auth Direct Setting 0 or 1 0 Selects the authentication method for SMPT Bit switch Bit 0 LOGIN Bit 1 PLAIN Bit 2 CRAM MD5 Bit 3 ...

Страница 344: ...rams from the original SD card in SD card slot 3 to an SD card in SD card slot 2 002 Undo Exec This SP copies back the application programs from an SD card in the SD Card Slot 3 to the original SD card in the SD card slot 2 Use this menu when you have mistakenly copied some programs by using Move Exec SP5873 1 5875 SC Auto Reboot 002 Reboot Type CTL Selects the reboot method for SC 0 or 1 0 0 Manu...

Страница 345: ...0 Disabled 1 Enabled Reboot machine to confirm the setting Bit Function Default 0 All access prohibition 0 1 All access prohibition for user mode 2 Print function prohibition 3 Fax transmitting prohibition 4 Scanner transmitting prohibition 5 DL function prohibition 6 Delete function prohibition 7 Access prohibition for guest user 050 DocSvr Format 0 Thumbnail 1 Icon 2 Detail Sets the way in which...

Страница 346: ...d for this SP 5888 Personal Information Protect Selects the protection level for logs 0 to 1 0 1 0 No authentication No protection for logs 1 No authentication Protected logs an administrator can see the logs 5893 SDK Apli Cnt Name CTL Displays the counter name of each SDK application 001 SDK 1 002 SDK 2 003 SDK 3 004 SDK 4 005 SDK 5 006 SDK 6 5894 External Counter Setting 001 Switch Charge Mode 0...

Страница 347: ... Permission Time 002 Print Application Timer Sets the length of time to elapse before allowing another application to take control of the display when the application currently controlling the display is not operating because a key has not been pressed 3 to 30 3 1 second step 5967 Copy Server Set Function 001 0 ON 2 OFF Sets the document server function ON OFF 5973 User Stamp Registration 001 Fram...

Страница 348: ...1 step 0 OFF 1 ON 5987 Mech Counter 0 OFF 1 ON 001 Gives the counter list text to the SD card inserted in the service slot In the SD card the folder named SD_COUNTER must be placed in the root directory 5990 SP Print Mode SMC Print In the SP mode press Copy Window to move to the copy screen select the paper size then press Start Select A4 LT Sideways or larger to ensure that all the information pr...

Страница 349: ...fo 026 Printer SP 5992 SP Text Mode This SP gives the SMC print text data to SD card inserted 001 All Data List 002 SP Mode Data List 003 User Program 004 Logging Data 005 Diagnostic Report 006 Non Default Prints only SPs set to values other than defaults 007 NIB Summary 008 Capture Log 021 Copier User Program 022 Scanner SP 023 Scanner User Program 024 SDK J Summary 025 SDK J Application Info 026...

Страница 350: ...System Service Mode D127 D128 3 94 SM Appendix 5994 Mirroring 001 Engine Execution type SP DFU 5995 Factory Mode 001 0 to 1 0 1 STEP step DFU ...

Страница 351: ...nt 5 0 to 5 0 0 0 0 1 mm step 004 Leading Edge Duplex Rear 5 0 to 5 0 0 0 0 1 mm step 007 Rear Edge Erase 5 0 to 5 0 0 0 0 1 mm step 6007 ADF INPUT Check 009 Original Detection 0 to 1 0 1 STEP step Displays ADF original sensor information When the sensor detects an original this SP s value becomes 1 013 Registration Sensor 0 to 1 0 1 STEP step Displays ADF registration sensor information When the ...

Страница 352: ...intermittent drive to check ADF condition against operational load 011 Inverter Solenoid ON OFF Makes the inverter solenoid intermittent drive to check ADF condition against operational load 6009 ADF Free Run 001 Simplex Mode 0 to 1 0 1 STEP step Performs an ARDF free run at simplex scanning mode Press ON to start press OFF to stop 002 Duplex Mode 0 to 1 0 1 STEP step Performs an ARDF free run in ...

Страница 353: ...X060050 2 for GX060040 6149 Max Pre Stack Sheet 001 0 to 3 3 1 Sheet s step 6910 ADF Adjustment Shading Time 0 to 90 60 1 Sec step 001 Adjusts the interval used for the shading processing in the ARDF mode Light and heat in the room may affect the scanner response Reduce this setting if copy quality indicates that the white level is drifting during ARDF copy jobs ...

Страница 354: ...rated including the number having been reset 7403 SC History 001 Latest Displays the most recent 10 service calls 002 Latest 1 003 Latest 2 004 Latest 3 005 Latest 4 006 Latest 5 007 Latest 6 008 Latest 7 009 Latest 8 010 Latest 9 7502 Total Paper Jam 0 to 65535 0 1 step 001 Jam Counter Jam Counter Displays the total number of copy paper jams 002 Total Jam Counter Total Jam Counter including the n...

Страница 355: ...m Location 0 to 9999 0 1 step Displays the total number of the paper jams classified by timing and location 001 At power on Paper jam occurs at power on 010 2nd Paper Feed SN Late 011 3rd Paper Feed SN Late 012 4th Paper Feed SN Late 021 LCT Paper Feed SN Late 022 1st Vertical Transport SN Late 050 2nd Vertical Transport SN Late 060 4th Vertical Transport SN Late 070 Relay SN Late 121 Registration...

Страница 356: ... paper remains at the sensor for longer than the prescribed time Late Jam occurs because paper fails to arrive at the prescribed time 1 Duplex Entrance SN Late 4 Duplex Transport SN1 Late 54 Duplex Transport SN2 Late 7506 Jam Count by Paper Size 006 A5 LEF CTL Displays the number of jams according to the paper size 0 to 9999 0 1 sheet step 044 HLT LEF 133 A4 SEF 134 A5 SEF 142 B5 SEF 164 LG SEF 16...

Страница 357: ...50 2000 CODE is the SP7504 number see above SIZE is the ASAP paper size code in hex TOTAL is the total jam error count SP7502 DATE is the date the jams occurred 002 Latest 1 003 Latest 2 004 Latest 3 005 Latest 4 006 Latest 5 007 Latest 6 008 Latest 7 009 Latest 8 010 Latest 9 Size Code Size Code Size Code A4 S 05 A3 L 84 DLT L A0 A5 S 06 A4 L 85 LG L A4 B5 S 0E A5 L 86 LT L A6 LT S 26 B4 L 8D HLT...

Страница 358: ...is the total error count SP7503 DATE is the date the jams occurred 002 Latest 1 003 Latest 2 004 Latest 3 005 Latest 4 006 Latest 5 007 Latest 6 008 Latest 7 009 Latest 8 010 Latest 9 7624 Parts Replacement Operation ON OFF PCDU BK 0 or 1 1 001 0 No 1 Yes Determines whether the use of PM applies to the machine or not After selecting Yes 1 confirm the SP5067 Parts replacement operation type setting...

Страница 359: ...e 45k part 0 to 255 0 1 step Displays the PM distance Counter 45k usage rate 007 Distance 90k part 0 to 255 0 1 step Displays the PM distance Counter 90k usage rate 7804 PM Count Reset 001 Paper Resets the PM counter SP7 803 001 When the program ends normally the message Completed is displayed 002 45k part PM counter 45k clear 003 90k part PM counter 90k clear 7807 SC Jam Counter Reset 001 Resets ...

Страница 360: ... failed at power on This error will occur if the device is installed but disconnected 7827 MF Error Counter Clear Press Execute to reset to 0 the values of SP7826 7832 Self Diagnose Result Display 001 Displays the SC codes and the number of their occurrences Each number is in the range of 0 to 9999 7836 Total Memory size Displays the contents of the memory on the controller board 7852 DF Glass Dus...

Страница 361: ...0k part 004 Distance mm 45k part Displays each of the PM distance Counter the last count 005 Distance mm 90k part 006 Distance 45k Displays each of the PM distance Counter usage rate the last count 007 Distance 90k 7907 Before 2 PM Count 002 Sheets 45k part Displays each of the PM sheet Counter 90k the second last count 003 Sheets 90k part 004 Distance mm 45k part Displays each of the PM distance ...

Страница 362: ...lays each of the PM sheet Counter 90k the third last count 003 Sheets 90k part 004 Distance mm 45k part Displays each of the PM distance Counter the third last count 005 Distance mm 90k part 006 Distance 45k Displays each of the PM distance Counter usage rate the third last count 007 Distance 90k ...

Страница 363: ...ork differently case by case Sometimes they count jobs pages stored on the document server this can be in document server mode from the document server window or from another mode such as from a printer driver or by pressing the Store File button in the Copy mode window Sometimes they include occasions when the user uses a file that is already on the document server Each counter will be discussed ...

Страница 364: ...ColCr Color Create ColMode Color Mode Comb Combine Comp Compression Deliv Delivery DesApl Designated Application The application Copy Fax Scan Print used to store the job on the document server for example Dev Counter Development Count no of pages developed Dup Duplex Duplex printing on both sides Emul Emulation FC Full Color FIN Post print processing i e finishing punching stapling etc Full Bleed...

Страница 365: ...ment server LSize Large paper Size Mag Magnification MC One color monochrome NRS NRS Remote which allows a service center to monitor machines remotely Remote is used overseas CSS is used in Japan Org Original for scanning OrgJam Original Jam Palm 2 Print Job Manager Desk Top Editor A pair of utilities that allows print jobs to be distributed evenly among the printers on the network and allows file...

Страница 366: ...printing on 1 side S to Email Scan to E mail SMC SMC report printed with SP5990 All of the Group 8 counters are recorded in the SMC report Svr Server TonEnd Toner End TonSave Toner Save TXJob Send Transmission YMC Yellow Magenta Cyan YMCK Yellow Magenta Cyan Black All of the Group 8 SPs are reset with SP5 801 1 Memory All Clear 8 191 T Total Scan PGS CTL These SPs count the pages scanned by each a...

Страница 367: ...ples If 3 B5 pages and 1 A3 page are scanned with the scanner application but not stored the S count is 4 If both sides of 3 A4 sheets are copied and stored to the document server using the Store File button in the Copy mode window the C count is 6 and the L count is 6 If both sides of 3 A4 sheets are copied but not stored the C count is 6 If you enter document server mode then scan 6 pages the L ...

Страница 368: ...ex scanning With an ADF ARDF that cannot scan both sides simultaneously the Front side count is the same as the number of pages fed for duplex front side scanning The front side is determined by which side the user loads face up 002 Back Number of rear sides fed for scanning With an ADF ARDF that can scan both sides simultaneously the Back count is the same as the number of pages fed for duplex sc...

Страница 369: ...amp CTL 8 295 S Scan PGS Stamp CTL 8 301 T Scan PGS Size CTL 0 to 99999999 0 1 These SPs count by size the total number of pages scanned by all applications Use these totals to compare original page size scanning and output printing page size SP 8 441 8 302 C Scan PGS Size CTL 0 to 99999999 0 1 These SPs count by size the total number of pages scanned by the Copy application Use these totals to co...

Страница 370: ...page size scanning and output page size SP 8 445 8 306 L Scan PGS Size CTL 0 to 99999999 0 1 The L counters work differently case by case Sometimes they count jobs pages stored on the document server Sometimes they include occasions when the user uses a file that is already on the document server 001 A3 002 A4 003 A5 004 B4 005 B5 006 DLT 007 LG 008 LT 009 HLT 010 Full Bleed 254 Other Standard 255...

Страница 371: ...r the application that stored them These counters are used primarily to calculate charges on use of the machine so the following pages are not counted as printed pages Blank pages in a duplex printing job Blank pages inserted as document covers chapter title sheets and slip sheets Reports printed to confirm counts All reports done in the service mode service summaries engine maintenance reports et...

Страница 372: ...plication 8 423 F PrtPGS Dup Comb CTL 0 to 99999999 0 1 These SPs count by binding and combining and n Up settings the number of pages processed for printing by the fax application 8 424 P PrtPGS Dup Comb CTL 0 to 99999999 0 1 These SPs count by binding and combining and n Up settings the number of pages processed for printing by the printer application 8 425 S PrtPGS Dup Comb CTL 0 to 99999999 0 ...

Страница 373: ...tions 001 Simplex Duplex 002 Duplex Duplex 003 Book Duplex 004 Simplex Combine 005 Duplex Combine 006 2in1 2 pages on 1 side 2 Up 007 4in1 4 pages on 1 side 4 Up 008 6in1 6 pages on 1 side 6 Up 009 8in1 8 pages on 1 side 8 Up 010 9in1 9 pages on 1 side 9 Up 011 16in1 16 pages on 1 side 16 Up 012 Booklet 013 Magazine 014 2in1 Booklet 015 4in1 Booklet 016 6in1 Booklet 017 8in1 Booklet 018 9in1 Bookl...

Страница 374: ...stomers who need to improve their compliance with ISO standards for the reduction of paper consumption Pages that are only partially printed with the n Up functions are counted as 1 page Here is a summary of how the counters work for Booklet and Magazine modes Booklet Magazine Original Pages Count Original Pages Count 1 1 1 1 2 2 2 2 3 2 3 2 4 2 4 2 5 3 5 4 6 4 6 4 7 4 7 4 8 4 8 4 ...

Страница 375: ...PrtPGS Ppr Size CTL 0 to 99999999 0 1 These SPs count by the number of the page classified by paper size The page is printed by the printer applications 8 445 S PrtPGS Ppr Size CTL 0 to 99999999 0 1 These SPs count by the number of the page classified by paper size The page is printed by the scanner applications 8 446 L PrtPGS Ppr Size CTL 0 to 99999999 0 1 The L counters work differently case by ...

Страница 376: ...999 0 1 These SPs count the number of sheets fed from each paper feed station 001 Bypass Bypass Tray 002 Tray 1 Copier 003 Tray 2 Copier 004 Tray 3 Copier 005 Tray 4 Currently not used 006 Tray 5 Currently not used 007 Tray 6 Currently not used 008 Tray 7 Currently not used 009 Tray 8 Currently not used 010 Tray 9 Currently not used 011 Tray 10 Currently not used 012 Tray 11 Currently not used 013...

Страница 377: ... of the feed rollers However these counts are based on output timing Blank sheets covers chapter covers slip sheets are also counted During duplex printing pages printed on both sides count as 1 and a page printed on one side counts as 1 8 462 C PrtPGS Ppr Type CTL 0 to 99999999 0 1 These SPs count by paper type the number pages printed by the copy application 8 463 F PrtPGS Ppr Type CTL 0 to 9999...

Страница 378: ...rver Sometimes they include occasions when the user uses a file that is already on the document server 001 Normal 002 Recycled 003 Special 004 Thick 005 Normal Back 006 Thick Back 007 OHP 008 Other 8 511 T PrtPGS Emul CTL 0 to 99999999 0 1 Printed by all applications 8 514 P PrtPGS Emul CTL 0 to 99999999 0 1 Printed by the printer application 001 RPCS 002 RPDL 003 PS3 004 R98 005 R16 006 GL GL2 ...

Страница 379: ...applications 8 522 C PrtPGS FIN CTL 0 to 99999999 0 1 These SPs count by finishing mode the total number of pages printed by the Copy application 8 523 F PrtPGS FIN CTL 0 to 99999999 0 1 These SPs count by finishing mode the total number of pages printed by the Fax application Print finishing options for received faxes are currently not available 8 524 P PrtPGS FIN CTL 0 to 99999999 0 1 These SPs ...

Страница 380: ...0 to 99999999 0 1 The L counters work differently case by case Sometimes they count jobs pages stored on the document server Sometimes they include occasions when the user uses a file that is already on the document server 001 Sort 002 Stack 003 Staple 004 Booklet 005 Z Fold 006 Punch 007 Other 008 Inside Fold 009 Three IN Fold 010 Three OUT Fold 011 Four Fold 012 KANNON Fold 013 Perfect Bind 014 ...

Страница 381: ...8 551 T PrtBooks FIN CTL 0 to 99999999 0 1 Printed by all applications 8 552 C PrtBooks FIN CTL 0 to 99999999 0 1 Printed by the printer application 8 554 P PrtBooks FIN CTL 0 to 99999999 0 1 Printed by the printer application 8 556 L PrtBooks FIN CTL 0 to 99999999 0 1 The L counters work differently case by case Sometimes they count jobs pages stored on the document server Sometimes they include ...

Страница 382: ... 8 564 P A Sheet Of Paper CTL 0 to 99999999 0 1 Printed by the printer application 8 566 L A Sheet Of Paper CTL 0 to 99999999 0 1 The L counters work differently case by case Sometimes they count jobs pages stored on the document server Sometimes they include occasions when the user uses a file that is already on the document server 8 567 O A Sheet Of Paper Printed by Other application 001 Total O...

Страница 383: ...999 0 1 001 A3 DLT These SPs count the totals for A3 DLT paper use number of duplex pages printed and the number of staples used These totals are for Other O applications only 002 Duplex 8 601 T Coverage Counter CTL 0 to 99999999 0 1 001 B W Displays the total coverage of each mode 011 B W Printing Pages Displays the number of the printouts in each mode 8 602 C Coverage Counter CTL 0 to 99999999 0...

Страница 384: ...ages sent by fax to a telephone number 001 B W If a document has color and black and white pages mixed the pages are counted separately as B W or Color At the present time this feature is provided for the Fax application only so SP8631 and SP8633 are the same The counts include error pages If a document is sent to more than one destination with a Group transmission the count is done for each desti...

Страница 385: ...sing I Fax 001 B W If a document has color and black and white pages mixed the pages are counted separately as B W or Color At the present time this feature is provided for the Fax application only so SP8641 and SP8643 are the same The counts include error pages If a document is sent to more than one destination with a Group transmission the count is done for each destination Polling transmissions...

Страница 386: ...is cancelled before it is stored the pages are not counted If Scan to Email is used to send a 10 page document to 5 addresses the count is 10 the pages are sent to the same SMTP server together If Scan to PC is used to send a 10 page document to 5 folders the count is 50 the document is sent to each destination of the SMB FTP server Due to restrictions on some devices if Scan to Email is used to s...

Страница 387: ...iv PGS Svr CTL 0 to 99999999 0 1 These SPs count by color mode the total number of pages sent to a Scan Router server by the Scan application 001 B W 002 Color The B W and Color counts are done after the document is stored on the HDD of the Scan Router server If the job is canceled before storage on the Scan Router server finishes the count is not done The count is executed even if there is confir...

Страница 388: ...er of pages stored is counted for the application that stored them When several documents are sent by a Fax broadcast the F count is done for the number of pages sent to each destination 8 681 T PCFAX TXPGS CTL These SPs count the number of pages sent by PC Fax These SPs are provided for the Fax application only so the counts for SP8 681 and SP8 683 are the same 0 to 99999999 0 1 8 683 F PCFAX TXP...

Страница 389: ... example if a 3 page original is sent to 4 destinations via ISDN G4 the count for ISDN G3 G4 is 12 001 PSTN 1 002 PSTN 2 003 PSTN 3 004 ISDN G3 G4 005 Network 8 711 T Scan PGS Comp CTL 0 to 99999999 0 1 8 715 S Scan PGS Comp CTL 0 to 99999999 0 1 These SPs count the number of pages sent by each compression mode 001 JPEG JPEG2000 002 TIFF M S Multi Single 003 PDF 004 Other 005 PDF Comp 006 PDF A ...

Страница 390: ... RX PGS Port 0 to 9999999 0 1 These SPs count the number of pages received by the physical port used to receive them 001 PSTN 1 002 PSTN 2 003 PSTN 3 004 ISDN G3 G4 005 Network 8 771 Dev Counter CTL 0 to 99999999 0 1 This SP counts the total number of developed images 001 Total 8 781 Toner Bottle Info BICU 0 to 99999999 0 1 This SP counts the total number of developed images 001 BK ...

Страница 391: ...upply 1 steps is better than other machines on the market that can only measure in increments of 10 10 steps 001 K 8 811 Eco Counter CTL 001 Eco Total 0 to 99999999 0 1 004 Duplex 005 Combine 008 Duplex 009 Combine 010 Paper Cut 101 Eco Total Last 104 Duplex Last 105 Combine Last 108 Duplex Last 109 Combine Last 110 Paper Cut Last 8 851 Cvr Cnt 0 10 BICU 0 to 99999999 0 1 These SPs display the num...

Страница 392: ... 001 Bk 8 871 Cvr Cnt 21 30 BICU 0 to 99999999 0 1 These SPs display the number of scanned sheets on which the coverage of each color is from 21 to 30 001 Bk 8 881 Cvr Cnt 31 BICU 0 to 99999999 0 1 These SPs display the number of scanned sheets on which the coverage of each color is 31 or higher 001 Bk 8 891 Page Toner Bottle BICU 0 to 99999999 0 1 This SP displays the number of sheets output by t...

Страница 393: ...ese SPs display the total coverage percentage of sheets output by the machine 011 Coverage P Bk 0 to 99999999 0 1 These SPs display the total coverage pages output by the machine 8 941 Machine Status CTL 0 to 99999999 0 1 These SPs count the amount of time the machine spends in each operation mode These SPs are useful for customers who need to investigate machine operation for improvement of their...

Страница 394: ...inting Does not include time machine remains powered off with the power switches 006 SC Total down time due to SC errors 007 PrtJam Total down time due to paper jams during printing 008 OrgJam Total down time due to original jams during scanning 009 Supply PM Unit End Total down time due to toner end 8 961 Electricity Status CTL 0 to 99999999 0 1 001 Ctrl Standby Time 002 STR Time 003 Main Power O...

Страница 395: ... 8 999 Admin Counter List CTL 0 to 9999999 0 1 Displays the user setting counter for administrator 001 Total 003 Copy BW 007 Printer BW 010 FaxP BW 013 Duplex 023 Copy BW 027 Printer BW 030 Fax Print BW 101 SedTtl FC 102 SendTtl BW 103 FaxSend 104 FaxSend BW 105 FaxSend BW ...

Страница 396: ...1 Thresh Warming up Low Temperature 0 to 50 16 1 deg step Sets the basic temperature for determination of the condition on machine startup 012 Disable Change Time 0 to 999 5 1 sec step Unused DO NOT change the setting 013 Total Count Clear Time 0 to 999 15 1 sec step When the wait time is over this SP s time the following three items are reset Control cycle on printing Repeat temperature correctio...

Страница 397: ...eg step 007 Added Temp T7 0 to 50 15 1 deg step 008 Added Temp T8 0 to 50 10 1 deg step 009 Added Temp T9 0 to 50 5 1 deg step 010 Added Temp T10 0 to 50 1 1 deg step 011 Added Temp T11 0 to 50 5 1 deg step 012 Added Temp T12 0 to 50 15 1 deg step 013 Added Temp T13 0 to 50 10 1 deg step 014 Added Temp T14 0 to 50 5 1 deg step 015 Added Temp T15 0 to 50 1 1 deg step 016 Added Temp T16 0 to 50 5 1 ...

Страница 398: ...28 0 to 50 22 1 deg step 029 Added Temp T29 0 to 50 5 1 deg step 030 Added Temp T30 0 to 50 1 1 deg step 031 Added Temp T31 0 to 50 40 1 deg step 032 Added Temp T32 0 to 50 20 1 deg step 033 Added Temp T33 0 to 50 17 1 deg step 034 Added Temp T34 0 to 50 5 1 deg step 035 Added Temp T35 0 to 50 1 1 deg step 036 Added Temp T36 0 to 50 35 1 deg step 037 Added Temp T37 0 to 50 20 1 deg step 038 Added ...

Страница 399: ... 999 15 1 sec step 007 Added Time S7 0 to 999 12 1 sec step 008 Added Time S8 0 to 999 10 1 sec step 009 Added Time S9 0 to 999 15 1 sec step 010 Added Time S10 0 to 999 15 1 sec step 011 Added Time S11 0 to 999 10 1 sec step 012 Added Time S12 0 to 999 15 1 sec step 013 Added Time S13 0 to 999 10 1 sec step 014 Added Time S14 0 to 999 10 1 sec step 015 Added Time S15 0 to 999 15 1 sec step 016 Ad...

Страница 400: ...mal 1 Force Time Sets the way of fusing reload 9930 Toner control NV Data 0 to 65535 0 1 sheet step 008 This SP s count is used as the flag of toner bottle replacement notice When the value becomes more than 1000 the notice will occur and the value will be cleared 9946 Fusing Jam Exist 0 to 1 0 1 step 001 0 Not fusing jam existing 1 Fusing jam existing This SP tells whether a fusing jam exists or ...

Страница 401: ...p 001 First duty 0 to 100 15 0 01 step 002 Duty step 0 to 100 5 0 01 step 003 Last duty 0 to 100 50 0 01 step 004 Repeat count 0 to 255 5 1 step 9961 Soft Start Print Soft start parameter on paper pass process 001 First duty 0 to 100 30 0 01 step 002 Duty step 0 to 100 5 0 01 step 003 Last duty 0 to 100 65 0 01 step 004 Repeat count 0 to 255 4 1 step 9962 Soft Stop Print Soft stop parameter on pap...

Страница 402: ...unt 0 to 255 4 1 step 9964 Soft Stop Wait Soft stop parameter on wait time 001 First duty 0 to 100 60 0 01 step 002 Duty step 0 to 100 10 0 01 step 003 Last duty 0 to 100 30 0 01 step 004 Repeat count 0 to 255 2 1 step 9966 Soft Start Print Soft start parameter on paper pass process 001 First duty 0 to 100 30 0 01 step 002 Duty step 0 to 100 5 0 01 step 003 Last duty 0 to 100 65 0 01 step 004 Repe...

Страница 403: ...01 step 004 Repeat count 0 to 255 2 1 step 9968 Soft Start Wait Soft start parameter on wait time 001 First duty 0 to 100 15 0 01 step 002 Duty step 0 to 100 5 0 01 step 003 Last duty 0 to 100 50 0 01 step 004 Repeat count 0 to 255 4 1 step 9969 Soft Stop Wait Soft stop parameter on wait time 001 First duty 0 to 100 60 0 01 step 002 Duty step 0 to 100 10 0 01 step 003 Last duty 0 to 100 30 0 01 st...

Страница 404: ...aper End Sensor Paper detected Not detected 019 Paper Exit Sensor Paper detected Not detected 022 Registration Sensor Paper detected Not detected 023 Interchange Sensor Paper detected Not detected 027 Front Safety SW 24V Closed Open 031 CTL Fan Lock Locked Not locked 033 Fan Lock Locked Not locked 035 Main Motor Lock Normal Abnormal 037 PCU Set Set Not Set 039 Key Card Set Set Not Set 040 Mechanic...

Страница 405: ...tected 093 Bank2 PE Paper detected Not detected 094 Bank1 Cover Open Closed 095 Bank2 Cover Open Closed 200 Scanner HP Sensor In Home Position Out of Home Position 201 Platen Cover Sensor Open Closed The items using more than 2 bits Num Sensor Switch Bit2 Bit1 Bit0 041 Key Counter Set Set Detected 1 Set Detected 2 042 BCU Version Ver 1 Ver 2 Ver 3 ...

Страница 406: ...umber see the table below corresponding to the component 3 Select ON 4 To stop the operation select OFF Output Check Table Num Component 001 Main Motor CW High 003 Main Motor CCW High 020 Toner Bottle Motor 025 Exhaust Fan Motor High 026 Exhaust Fan Motor Low 028 CTL Fan 032 Registration CL 033 1st Paper Feed CL 040 Fusing SOL 041 Dehumidification Heater 042 P P Image Transfer 043 P P Image Transf...

Страница 407: ...9 Bank1 Clutch 170 Bank2 Clutch 202 Scanner Lamp Color 600 203 Scanner Lamp Color 1200 204 Scanner Lamp Bk When checking Fan Motor High 005 or Fan Motor Low 006 note the following These motors may not respond when the fusing temperature is high Selecting ON checks that one of these motors normally operates Selecting OFF turns off the motor that you have started by selecting ON However this does no...

Страница 408: ...imeouts Enabled The MFP I O Timeout setting will have no affect I O Timeouts will never occur bit 4 SD Card Save Mode 0 Disable 1 Enable Enabled Print jobs will be saved to an SD Card in the GW SD slot Card Save Function in the service tables of Field Service Manual bit 5 DFU bit 6 DFU bit 7 RPCS PCL Printable area frame border 0 Disable 1 Enable Enable The machine prints all RPCS and PCL jobs wit...

Страница 409: ... PS PDL Auto Switching 0 Enable 1 Disable Disabled The MFPs ability to change the PDL processor mid job Some host systems submit jobs that contain both PS and PCL5e c If Auto PDL switching is disabled these jobs will not be printed properly bit 4 DFU bit 5 DFU bit 6 DFU bit 7 DFU 1001 Bit Switch 003 Bit Switch 3 0 1 bit 0 DFU bit 1 DFU bit 2 PCL5e c Legacy HP compatibility 0 Disable 1 Enable Enabl...

Страница 410: ... copy is output by default Using this BitSw the device can be configured to print all copies even if a paper mismatch occurs bit 2 DFU bit 3 PS PS Criteria Pattern3 Pattern1 Change the number of PS criterion used by the PS interpreter to determine whether a job is PS data or not Pattern3 includes most PS commands Pattern1 A small number of PS tags and headers bit 4 Increase max number of the store...

Страница 411: ...The old models are below PCL Pre 04A models bit 7 Letterhead mode printing Disable Enable Duplex Routes all pages through the duplex unit If this is disabled simplex pages or the last page of an odd paged duplex job are not routed through the duplex unit This could result in problems with letterhead pre printed pages 1001 Bit Switch 006 Bit Switch 6 DFU 1001 Bit Switch 007 Bit Switch 7 DFU 1001 Bi...

Страница 412: ...ays the version of the controller firmware 1006 1 Sample Locked print 0 Link with Doc srv 1 Enable Enables and disables the document server When you select 0 the document server is enabled or disables in accordance with copy service mode SP5 967 When you select 1 the document server is enabled regardless of service mode SP5 967 1110 2 Media Print Device Setting 0 Disabled 1 Enabled Sets I F USB SD...

Страница 413: ...on Function and Setting 5801 001 Memory All Clear Resets data for process control and all software counters and returns all modes and adjustments to their defaults values Section Memory Clear in this chapter for details 5907 Plug Play Maker Model Name Selects the brand name and the production name for Windows Plug Play This information is stored in NVRAM 7832 Self Diagnose Result Display Displays ...

Страница 414: ...FU Denotes Design or Factory Use Do not change this value SP1 Mode Number Function and Setting 1001 5 Scan NV Version Displays the scanner NV version This shows as following Function name _ Model name _ Version 1005 1 Erase Margin Remote Scan Range from 0 to 5 mm Creates an erase margin for all edges of the scanned image The margin color Black or White depends on color tone and invert settings 0 t...

Страница 415: ... 1 1 0 OFF 1 ON SP Number Name Function and Setting 2021 Compression level grayscale These SP codes set the compression ratio for the grayscale or full color processing mode that can be selected with the notch settings on the operation panel Range 5 lowest ratio 95 highest ratio 1 Comp1 5 95 Middle I Qual 5 to 95 20 1 step 2 Comp2 5 95 High I Qual 5 to 95 40 1 step 3 Comp3 5 95 Low I Qual 5 to 95 ...

Страница 416: ...io Normal 5 to 95 25 1 step 2 Compression Ratio High 5 to 95 20 1 step SP Number Name Function and Setting 2025 Compression ratio of ClearLightPDF JPEG2000 These SP codes set the compression ratio for the clear light PDF processing mode For JPEG 2000 Range 5 lowest ratio 95 highest ratio 1 Compression Ratio Normal JPEG2000 5 to 95 25 1 step 2 Compression Ratio High JPEG2000 5 to 95 20 1 step For t...

Страница 417: ...APPENDIX FAX TROUBLESHOOTING GUIDE REVISION HISTORY Page Date Added Updated New None ...

Страница 418: ......

Страница 419: ...nd on the service report Code Meaning Suggested Cause Action 0 00 DIS NSF not detected within 40 s of Start being pressed Check the line connection The machine at the other end may be incompatible Replace the NCU or FCU Check for DIS NSF with an oscilloscope If the rx signal is weak there may be a bad line 0 01 DCN received unexpectedly The other party is out of paper or has a jammed printer The o...

Страница 420: ...r 01 PSTN Cable equalizer G3 Switch 07 PSTN Dedicated Tx parameters in Service Program Mode 0 05 Modem training fails even G3 shifts down to 2400 bps Check the line connection Try adjusting the tx level and or cable equalizer Replace the FCU Check for line problems Cross reference See error code 0 04 0 06 The other terminal did not reply to DCS Check the line connection Try adjusting the tx level ...

Страница 421: ...too many errors Check the line connection Replace the NCU or FCU The other end may have jammed or run out of paper or memory space Try adjusting the tx level and or cable equalizer settings The other end may have a defective modem NCU FCU try sending to another machine Check for line problems and noise Cross reference Tx level NCU Parameter 01 PSTN Cable equalizer G3 Switch 07 PSTN Dedicated Tx pa...

Страница 422: ...l level is too low there may be a line problem Cross reference See error code 0 08 0 20 Facsimile data not received within 6 s of retraining Check the line connection Replace the NCU or FCU Check for line problems Try calling another fax machine Try adjusting the reconstruction time for the first line and or rx cable equalizer setting Cross reference Reconstruction time G3 Switch 0A bit 6 Rx cable...

Страница 423: ...ther line problems Try asking the other end to adjust their tx level Try adjusting the rx cable equalizer setting and or rx error criteria Cross reference Rx cable equalizer G3 Switch 07 PSTN Rx error criteria Communication Switch 02 bits 0 and 1 0 30 The other terminal did not reply to NSS A in AI short protocol mode Check the line connection Try adjusting the tx level and or cable equalizer sett...

Страница 424: ...e other terminal when polling rx was initiated from the calling terminal 0 74 The calling terminal fell back to T 30 mode because it could not detect ANSam after sending CI The calling terminal could not detect ANSam due to noise etc ANSam was too short to detect Check the line connection and condition Try making a call to another V 8 V 34 fax 0 75 The called terminal fell back to T 30 mode becaus...

Страница 425: ...a call at a later time Try using V 17 or a slower modem using dedicated tx parameters Try increasing the tx level Try adjusting the tx cable equalizer setting If these errors happen at the receiving terminal Try adjusting the rx cable equalizer setting Try increasing the tx level Try using V 17 or a slower modem if the same error is frequent when receiving from multiple senders 0 81 The line was d...

Страница 426: ...disconnected because PPR was transmitted received 9 default times within the same ECM frame Try using a lower data rate at the start Try adjusting the cable equalizer setting 2 11 Only one V 21 connection flag was received Replace the FCU 2 12 Modem clock irregularity Replace the FCU 2 13 Modem initialization error Turn off the machine then turn it back on Update the modem ROM Replace the FCU 2 23...

Страница 427: ... msg in the manual task is an error because the mailbox for the operation task is full The user did the same operation many times and this gave too much load to the machine 4 01 Line current was cut Check the line connector Check for line problems Replace the FCU or the NCU 4 10 Communication failed because of an ID Code mismatch Closed Network or Tel No CSI mismatch Protection against Wrong Conne...

Страница 428: ...6 02 G3 ECM EOR was received 6 04 G3 ECM RTC not detected Check the line connection Check for a bad line or defective remote terminal Replace the FCU 6 05 G3 ECM facsimile data frame not received within 18 s of CFR but there was no line fail Check the line connection Check for a bad line or defective remote terminal Replace the FCU Try adjusting the rx cable equalizer Cross reference Rx cable equa...

Страница 429: ...chine resets the sequence because of an abnormal handshake in the V 34 control channel Check for line noise If the same error occurs frequently replace the FCU Defective remote terminal 6 99 V 21 signal not stopped within 6 s Replace the FCU 13 17 SIP user name registration error Double registration of the SIP user name Capacity for user name registration in the SIP server is not sufficient 13 18 ...

Страница 430: ...direct SMTP sending and check the sending destination 14 03 Access to SMTP Server Denied 450 Failed to access the SMTP server because the access is denied SMTP server operating incorrectly Contact the system administrator to determine if there is a problem with the SMTP server and to check that the SMTP server settings are correct Folder send destination is incorrect Contact the system administrat...

Страница 431: ...TP direct sending Contact the system administrator and check the amount of space remaining on the target HDD 14 06 User Not Found on SMTP Server 551 The designated user does not exist The designated user does not exist on the SMTP server The designated address is not for use with direct SMTP sending 14 07 Data Send to SMTP Server Failed 4XX Failed to access the SMTP server because the transmission...

Страница 432: ...large 14 13 Send Cancelled Processing is interrupted because the user pressed Stop 14 14 Security Locked File Error Update the software because of the defective software 14 15 Mail Data Error The transmitting a mail is interrupted via DCS due to the incorrect data Update the software because of the defective software 14 16 Maximum Division Number Error When a mail is divided for the mail transmiss...

Страница 433: ...nd send was cancelled due to a software error 14 33 No Mail Address For the Machine Neither the mail address of the machine nor the mail address of the network administrator is registered 14 34 Address designated in the domain for SMTP sending does not exist Operational error in normal mail sending or direct SMTP sending Check the address selected in the address book for SMTP sending Check the dom...

Страница 434: ...MAP4 Mail Account Information Not Registered The POP3 IMAP4 mail account has not been registered 15 03 Mail Address Not Registered The mail address has not been registered 15 10 DCS Mail Receive Error Error other than 15 11 to 15 18 15 11 Connection Error The DNS or POP3 IMAP4 server could not be found The IP address for DNS or POP3 IMAP4 server is not stored in the machine The DNS IP address is n...

Страница 435: ... was received 15 31 Final Destination for Transfer Request Reception Format Error The format of the final destination for the transfer request was incorrect 15 39 Send Delivery Destination Error The transmission cannot be delivered to the final destination Destination file format is incorrect Could not create the destination for the file transmission 15 41 SMTP Receive Error Reception rejected bec...

Страница 436: ...IFF header is incorrect The TIFF file attachment is a type not supported The TIFF file attachment is corrupted Software error 15 64 TIFF Decompression Error The file received as an attachment caused the TIFF decompression error The TIFF format of the attachment is corrupted Software error 15 71 Not Binary Image Data The file could not be received because the attachment was not binary image data 15...

Страница 437: ...r to the final destination The format of the final destination or the transfer destination is incorrect Destinations are full so the final and transfer destinations could not be created 15 92 Memory Overflow Transmission could not be received because memory overflowed during the transaction 15 93 Memory Access Error Transaction could not complete due to a malfunction of SAF memory 15 94 Incorrect ...

Страница 438: ...ormally but did not finish normally data may or may not have been received fully Restart the machine 22 04 The machine cannot store received data in the SAF Update the ROM Replace the FCU 22 05 No G3 parameter confirmation answer Defective FCU board or firmware 23 00 Data read timeout during construction Restart the machine Replace the FCU 25 00 The machine software resets itself after a fatal tra...

Страница 439: ... can communicate through the LAN Between IFAX and PC 1 Network settings on the PC Check the network settings on the PC Is the IP address registered in the TCP IP properties in the network setup correct Check the IP address with the administrator of the network 2 Check that PC can connect with the machine Use the ping command on the PC to contact the machine At the MS DOS prompt type ping then the ...

Страница 440: ...etween machine and e mail server 1 E mail account on the server Make sure that the machine can log into the e mail server Check that the account and password stored in the server are the same as in the machine Ask the administrator to check 2 E mail server Make sure that the client devices which have an account in the server can send receive e mail Ask the administrator to check Send a test e mail...

Страница 441: ...as the destination The machine receives the returned e mail if the communication is performed successfully 3 Destination e mail address Make sure that the e mail address is actually used Check that the e mail address contains no incorrect characters such as spaces Between e mail server and internet Router settings Use the ping command to contact the router Check that other devices connected to the...

Страница 442: ... another method Fax Internet Fax 4 Transmission sent manually Manual sending not supported 5 IP address of local machine registered Register the IP address 6 Remote terminal port number setting other than 1720 Send by specifying the port number 7 Specified port number correct Confirm the port number of the remote fax 8 DNS server registered when host name specified Contact the network administrato...

Страница 443: ...ion 1 LAN cable connected Check the LAN cable connection 2 VoIP Gateway T 38 standard Contact the network administrator 3 VoIP Gateway installed correctly Contact the network administrator 4 VoIP Gateway power switched on Contact the network administrator 5 Is the IP address host name of the specified Gateway correct Check the IP address host name 6 Number of the specified fax correct Check the re...

Страница 444: ...W 01 Bit 0 to 3 IP Fax bandwidth is the same as the DCS speed Set IP Fax SW00 Bit 6 to 1 Cannot send by Alias Fax number Check Point Action 1 LAN cable connected Check the LAN cable connection 2 Number of specified Alias fax correct Confirm the Alias of the remote fax Error Code 13 14 3 Firewall NAT installed Cannot breach the firewall Send by using another method Fax Internet Fax 4 Transmission s...

Страница 445: ...ocal fax registered Register the Alias number of the local fax 12 Remote fax registered in Gatekeeper Contact the network administrator 13 Remote fax a T 38 terminal Check whether the remote fax is a T38 terminal 14 Remote fax switched off or busy Contact the network administrator 15 Network bandwidth too narrow Request the system administrator to increase the bandwidth Raise the delay level IPFAX...

Страница 446: ...er fax if required Request the sender to specify the port number 5 Specified port number correct if required Request the sender to check the port number 6 DNS server registered when host name specified on sender side Contact the network administrator The sender machine displays this error code if the sender fax is a Ricoh model 7 Network bandwidth too narrow Request the system administrator to inc...

Страница 447: ... correctly Contact the network administrator 4 VoIP Gateway power switched on Contact the network administrator 5 IP address host name of specified VoIP Gateway correct on sender s side Request the remote fax to check the IP address host name 6 DNS server registered when host name specified on sender side Contact the network administrator 7 Network bandwidth too narrow Request the network administ...

Страница 448: ...ekeeper installed correctly Contact the network administrator The sender machine displays this error code when the sender fax is a Ricoh model 4 Power to Gatekeeper switched on Contact the network administrator The sender machine displays this error code when the sender fax is a Ricoh model 5 IP address host name of Gatekeeper correct on the sender s side Request the sender to check the IP address...

Страница 449: ... Only if the remote sender fax is a Ricoh fax 8 Local fax IP address registered Register the IP address 9 Local fax Alias number registered Register the Alias number 10 Network bandwidth too narrow Request the system administrator to increase the bandwidth Lower the start modem reception baud rate on the receiving side IPFAX SW06 11 Remote fax cancelled transmission Check whether the remote fax ca...

Страница 450: ......

Страница 451: ...APPENDIX FAX SERVICE PROGRAM REVISION HISTORY Page Date Added Updated New None ...

Страница 452: ......

Страница 453: ... 8 Bit Switches 102 Ifax Switch 001 016 00 0F Change the bit switches for internet fax settings for the fax option p 5 8 Bit Switches 103 Printer Switch 001 016 00 0F Change the bit switches for printer settings for the fax option p 5 8 Bit Switches 104 Communication Switch 001 032 00 1F Change the bit switches for communication settings for the fax option p 5 8 Bit Switches 105 G3 1 Switch 001 01...

Страница 454: ...ax parameters p 5 8 Bit Switches 5 1 2 SP2 XXX RAM 2 Mode No Function 101 RAM Read Write 001 Change RAM data for the fax board directly 102 Memory Dump 001 G3 1 Memory Dump Print out RAM data for the fax board 103 G3 1 NCU Parameters 001 023 CC 01 22 NCU parameter settings for the standard G3 board p 5 69 NCU Parameters ...

Страница 455: ... line type setting for the G3 1 line If the machine is installed on a PABX line select PABX PABX GND or PABX FLASH 002 PSTN Access Number Enter the PSTN access number for the G3 1 line 003 Memory Lock Disabled If the customer does not want to receive transmissions using Memory Lock on this line turn this SP on 107 IPFAX Port Settings 001 H323 Port 002 SIP Port 003 RAS Port 004 Gatekeeper port 005 ...

Страница 456: ... parameters user data in the SRAM files in the SAF memory and clock 102 Erase All Files 001 Erases all files stored in the SAF memory 103 Reset Bit SW Except secure 001 Resets the bit switches and user parameters 104 Factory Setting 001 Resets the bit switches and user parameters user data in the SRAM and files in the SAF memory 105 Reset All Bit Switches 001 Initializes all the current bit switch...

Страница 457: ...ll communications for the G3 1 line 003 G3 1 1 Communication Prints the protocol dump list of the last communication for the G3 1 line 105 All Files Print out 001 Prints out all the user files in the SAF memory including confidential messages Do not use this function unless the customer is having trouble printing confidential messages or recovering files stored using the memory lock feature 106 Jo...

Страница 458: ...RAP Stored 004 Decompression 005 Scanner 006 JOB SAF 007 Reconstruction 008 JBIG 009 Fax Driver 010 G3CCU 011 Fax Job 012 CCU 013 Scanner Condition 108 IP Protocol Dump List 001 All Communications Prints the protocol dump list of all communications for the IP fax line 002 1 Communication Prints the protocol dump list of the last communication for the IP fax line ...

Страница 459: ...5 1 7 SP7 XXX TESTS These are the test modes for PTT approval 101 G3 1 Modem Tests 102 G3 1 DTMF Tests 103 Ringer 104 G3 1 V34 Tests S2400baud 105 G3 1 V34 Tests S2800baud 106 G3 1 V34 Tests S3000baud 107 G3 1 V34 Tests S3200baud 108 G3 1 V34 Tests S3429baud 109 Recorded Message Test ...

Страница 460: ...in this manual Refer to the System Parameter List printed by the machine 5 2 1 SYSTEM SWITCHES System Switch 00 SP No 1 101 001 No FUNCTION COMMENTS 0 Dedicated transmission parameter programming 0 Disabled 1 Enabled Set this bit to 1 before changing any dedicated transmission parameters Reset this bit to 0 after programming dedicated transmission parameters 1 Not used Do not change 2 Technical da...

Страница 461: ...he rx level The high byte is given first followed by the low byte Divide the decimal value of N by 16 to get the rx level In the above example the decimal value of N 0100 H is 256 So the actual rx level is 256 16 16 dB 3 Not used Do not change this setting 4 Line error mark print 0 OFF 1 ON print When 1 is selected a line error mark is printed on the printout if a line error occurs during receptio...

Страница 462: ...lding function 0 Following User SW 24 bit 1 1 Permanent hold 5 Not used Do not change these settings 6 7 Memory read write by RDS Bit 7 0 Bit 6 0 Always disabled Bit 7 0 Bit 6 1 User selectable Bit 7 1 Bit 6 0 User selectable Bit 7 1 Bit 6 1 Always enabled 0 0 All RDS systems are always locked out 0 1 1 0 Normally RDS systems are locked out but the user can temporarily switch RDS on to allow RDS o...

Страница 463: ...ed Do not change these settings 3 Printing dedicated tx parameters on Quick Speed Dial Lists 0 Disabled 1 Enabled 1 Each Quick Speed dial number on the list is printed with the dedicated tx parameters 10 bytes each The first 10 bytes of data are the programmed dedicated tx parameters 34 bytes of data are printed the other 24 bytes have no use for service technicians 4 7 Not used Do not change thes...

Страница 464: ... report printout 0 Disabled 1 Enabled 0 Error reports will not be printed 1 Error reports will be printed automatically after failed communications 3 Printing of the error code on the error report 0 No 1 Yes 1 Error codes are printed on the error reports 4 Not used Do not change this setting 5 Power failure report 0 Disabled 1 Enabled 1 A power failure report will be automatically printed after th...

Страница 465: ... settings 4 Dialing on the ten key pad when the external telephone is off hook 0 Disabled 1 Enabled 0 Prevents dialing from the ten key pad while the external telephone is off hook Use this setting when the external telephone is not by the machine or if a wireless telephone is connected as an external telephone 1 The user can dial on the machine s ten key pad when the handset is off hook 5 On hook...

Страница 466: ...witch 0F SP No 1 101 016 No FUNCTION COMMENTS 0 7 Country area code for functional settings Hex This country area code determines the factory settings of bit switches and RAM addresses However it has no effect on the NCU parameter settings and communication parameter RAM addresses Cross reference NCU country code SP No 2 103 001 for G3 1 00 France 11 USA 01 Germany 12 Asia 02 UK 13 Japan 03 Italy ...

Страница 467: ...witch 11 SP No 1 101 018 No FUNCTION COMMENTS 0 TTI printing position 0 Superimposed on the page data 1 Printed before the data leading edge Change this bit to 1 if the TTI overprints information that the customer considers to be important G3 transmissions 1 2 Not used Japan Only 3 TTI used for broadcasting 0 The TTIs selected for each Quick Speed dial are used 1 The same TTI is used for all desti...

Страница 468: ...etting determines the print start position for the TTI from the left edge of the paper If the TTI is moved too far to the right it may overwrite the file number which is on the top right of the page On an A4 page if the TTI is moved over by more than 50 mm it may overwrite the page number System Switch 13 Not used do not change these settings System Switch 14 Not used do not change these settings ...

Страница 469: ...ine from entering Energy Saver mode if there is a pending transmission file Bit 5 0 Bit 4 0 1 min Bit 5 0 Bit 4 1 30 min1 Bit 5 1 Bit 4 0 1 hour Bit 5 1 Bit 4 1 24 hours If there is a file waiting for transmission the machine does not go to Energy Saver mode during the selected period After transmitting the file if there is no file waiting for transmission the machine goes to the Energy Saver mode...

Страница 470: ... a form or letterhead which has a colored or printed background change this bit to 1 Original 1 and Original 2 can be selected in addition to the Text Text Photo and Photo modes System Switch 1A SP No 1 101 027 No FUNCTION COMMENTS 0 7 LS Rx Memory threshold value setting 00 FF HEX 0 1020 k Byte Default 0x80 512k Byte The received document is printed automatically after the memory remaining amount...

Страница 471: ... records before the machine can print them 1 If the buffer memory of the communication records for the Journal is full fax communications are still possible But the machine will overwrite the oldest communication records Note This setting is effective only when Automatic Journal printout is enabled but the machine cannot print the report e g no paper 1 Action when the SAF memory has become full du...

Страница 472: ...this bit at 0 default setting 5 7 Not used Do not change the settings System Switch 1F SP No 1 101 032 No FUNCTION COMMENTS 0 Not used Do not change the settings 1 Report printout after an original jam during SAF storage or if the SAF memory fills up 0 Enabled 1 Disabled 0 When an original jams or the SAF memory overflows during scanning a report will be printed Change this bit to 1 if the custome...

Страница 473: ...e Fax SC codes See Troubleshooting 5 2 2 I FAX SWITCHES I fax Switch 00 SP No 1 102 001 No FUNCTION COMMENTS Original size limitation of TX Attachment File These settings set the size applying to adjusting the transmitted original data so that the destination can receive within its capacity 0 A4 0 Not selected 1 Selected This function can keep a transmitting operation from a destination s incapaci...

Страница 474: ...ersion for mail transmission 0 Off No conversion 1 On Conversion When on set to 1 the machine converts millimeters to inches for sending mail There is no switch for converting inches to millimeters Unlike G3 fax transmissions which can negotiate between sender and receiver to determine the setting mail cannot negotiate between terminals the mm inch selection is determined by the sender fax When th...

Страница 475: ...il with only binary data is received a TIFF F file for example this setting is ignored and no header is printed 1 Output from Attached Document at E mail TX Error This setting determines whether only the first page or all pages of an e mail attachment are printed at the sending station when a transmission error occurs This allows the customer to see which documents have not reached their intended ...

Страница 476: ... received by Microsoft Outlook 2000 may cause an error If any setting other than displayed 01 causes a problem change the setting to 01 to enable normal sending of the Return Receipt 4 Media accept feature This setting adds or does not add the media accept feature to the answer mail to confirm a reception 0 Does not add the media accept feature to the answer mail 1 Adds the media accept feature to...

Страница 477: ... switch is used to transfer and deliver mail to a PC the information in the Subject line that indicates where the transmission originated can be used to determine automatically the destination folder for each e mail 1 Subject corresponding to mail post database 0 Standard subject 1 Mail post database subject The standard subject is replaced by the mail post database subject in the following three ...

Страница 478: ...n an error occurs 2 7 Not used I fax Switch 06 Not used do not change the settings SP No 1 102 007 I fax Switch 07 Not used do not change the settings SP No 1 102 008 I fax Switch 08 SP No 1 102 009 No FUNCTION COMMENTS 0 7 Memory Threshold for POP Mail Reception This setting determines the amount of SAF Store and Forward memory SAF stores fax messages to send later for transmission to more than o...

Страница 479: ...h 0C Not used do not change the settings SP No 1 102 013 I fax Switch 0D SP No 1 102 014 No FUNCTION COMMENTS 0 1 Not used 2 3 Signature on Transmitting for Result Notification Individual Settings Bit SW 3 2 0 0 Not attached 0 1 Setting forbidden 0 1 Individual settings Initial Setting 0 1 Attached at all times Signature settings on result notification mail This function applies to the following n...

Страница 480: ... Files This setting determines whether files received with SMTP protocol are delivered or output immediately 0 Off Files received via SMTP are output immediately without delivery 1 On Files received via SMTP are delivered immediately to their destinations 1 Signature setting for SMTP RX Files This setting determines whether the signature is attached or not on files received with SMTP protocol 0 Of...

Страница 481: ...he size of the paper is smaller than the size of the document received When A5 is used to print an A4 size document for example 1 Repetition of data when the received page is longer than the printer paper 0 Off 1 On 1 Default 10 mm of the trailing edge of the previous page are repeated at the top of the next page 0 The next page continues from where the previous page stopped without any repeated t...

Страница 482: ...ting fax messages and reports Do not disable usage for a paper feed station which has been specified by User Parameter Switch 0F 15 or which is used for the Specified Cassette Selection feature 1 2nd paper feed station usage for fax printing 0 Enabled 1 Disabled 2 3rd paper feed station usage for fax printing 0 Enabled 1 Disabled 3 4th paper feed station usage for fax printing 0 Enabled 1 Disabled...

Страница 483: ...inting Maximum reducible length Printer Switches 04 bits 0 to 4 1 3 Not used Do not change the settings 4 7 Page separation setting when sub scan compression is forbidden 00 0F 0 15 mm Hex Default 6 mm Page separation threshold with reduction disabled with switch 03 0 above For example if this setting is set to 10 and A4 is the selected paper size If the received document is 10 mm or less longer t...

Страница 484: ... bits 0 to 4 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Setting 0 0 0 0 0 0 mm 0 0 0 0 1 5 mm 0 0 1 0 0 20 mm 1 1 1 1 1 155 mm For A5 sideways and B5 sideways paper Maximum reducible length Paper length 0 75 x N x 5mm 5 6 Length of the duplicated image on the next page when page separation has taken place Bit 6 0 Bit 5 0 4 mm Bit 6 1 Bit 5 0 10 mm Bit 6 0 Bit 5 1 15 mm Bit 6 1 Bit 5 1 Not used 7 Not used Do no...

Страница 485: ...8 No FUNCTION COMMENTS 0 3 Not used Do not change the settings 4 List of destinations in the Communication Failure Report for broadcasting 0 All destinations 1 Only destinations where communication failure occurred 1 Only destinations where communication failure occurred are printed on the Communication Failure Report 5 7 Not used Do not change the settings Printer Switch 08 Not used do not change...

Страница 486: ...chine has both A4 and 8 5 x 11 size paper 2 Page separation 0 Enabled 1 Disabled 1 If all paper sizes in the machine require page separation to print a received fax message the machine does not print the message Substitute Reception is used After a larger size of paper is set in a cassette the machine automatically prints the fax message 3 4 Printing the sample image on reports Bit 4 0 Bit 3 0 The...

Страница 487: ...ithout reduction Printer Switch 0F SP No 1 103 016 No FUNCTION COMMENTS 0 1 Smoothing feature Bit 1 0 Bit 0 0 Disabled Bit 1 0 Bit 0 1 Disabled Bit 1 1 Bit 0 0 Enabled Bit 1 1 Bit 0 1 Not used 0 0 0 1 Disable smoothing if the machine receives halftone images from other manufacturers fax machines frequently 2 Duplex Print Setting 0 Disabled 1 Enabled This function is available only when the Duplex ...

Страница 488: ...1 Bit 2 1 MH MR MMR JBIG These bits determine the compression capabilities to be used in the transmission and to be declared in phase B handshaking of the T 30 protocol 4 Not used Do not change the settings 5 JBIG compression method Reception 0 Only basic supported 1 Basic and optional both supported Change the setting when communication problems occur using JBIG compression 6 JBIG compression met...

Страница 489: ...4 5 Not used Do not change the setting 6 7 Maximum printable page length available Bit 7 0 Bit 6 0 No limit Bit 7 0 Bit 6 1 B4 364 mm Bit 7 1 Bit 6 0 A4 297 mm Bit 7 1 Bit 6 1 Not used The setting determined by these bits is informed to the transmitting terminal in the pre message protocol exchange in the DIS NSF frames Communication Switch 02 SP No 1 104 003 No FUNCTION COMMENTS 0 G3 Burst error ...

Страница 490: ...ved 1 The machine will send DCN and hang up if it receives RTN or PIN This bit is ignored for memory transmissions or if ECM is being used 4 7 Not used Do not change the settings Communication Switch 03 SP No 1 104 004 No FUNCTION COMMENTS 0 7 Maximum number of page retransmissions in a G3 memory transmission 00 FF Hex times This setting is not used if ECM is switched on Default setting 03 H Commu...

Страница 491: ...09 0 9 HEX Selects the handset number pushed to switch between TEL FAX 4 7 Not used Do not change the settings Communication Switch 06 Not used do not change the settings Communication Switch 07 Not used do not change the settings Communication Switch 08 Not used do not change the settings Communication Switch 09 SP No 1 104 010 No FUNCTION COMMENTS 0 7 IP Fax dial interval setting Adjusts the int...

Страница 492: ...gins from the first page using normal memory transmission 1 7 Not used Do not change the settings Communication Switch 0B SP No 1 104 012 No FUNCTION COMMENTS 0 3 Not used do not change the settings 4 Received file output ON OFF selection for multiple relayed communications 0 OFF 1 ON Determines whether received file s is printed out or not by the relaying copier on multiple relayed communications...

Страница 493: ... receive any fax messages If this setting is kept at 0 the machine will detect ringing signals and go into receive mode even if there is no memory available This will result in communication failure Communication Switch 0E SP No 1 104 015 No FUNCTION COMMENTS 0 7 Minimum interval between automatic dialing attempts 06 to FF Hex unit 2 s e g 06 H 12 s This value is the minimum time that the machine ...

Страница 494: ...COMMENTS 0 Inch to mm conversion during transmission 0 Disabled 1 Enabled 0 In immediate transmission data scanned in inch format are transmitted without conversion In memory transmission data stored in the SAF memory in mm format are transmitted without conversion Note When storing the scanned data into SAF memory the fax unit always converts the data into mm format 1 The machine converts the sca...

Страница 495: ...tch 17 SP No 1 104 024 No FUNCTION COMMENTS 0 SEP Selective polling reception Enabled Disabled switch 0 Disabled 1 Enabled Enabled means SEP Selective polling is acceptable on reception 1 SUB password locked data reception Enabled Disabled switch 0 Disabled 1 Enabled Enabled means SUB confidential transmission is acceptable on reception 2 PWD password reception Enabled Disabled switch 0 Disabled 1...

Страница 496: ... dial in routine does on IP FAX enable disable Default is 0 Disable 6 7 Not used Do not change the settings Communication Switch 19 Not used do not change the settings Communication Switch 1A Not used do not change the settings Communication Switch 1B SP No 1 104 028 No FUNCTION COMMENTS 0 7 Extension access code 0 to 7 to turn V 8 protocol On Off 0 On 1 Off If the PABX does not support V 8 V 34 p...

Страница 497: ...munication switch 1B Example If 8 is the PSTN access code set bit 0 to 1 When the machine detects 8 as the first dialed number it automatically disables V 8 protocol If 9 is the PSTN access code use bit 1 2 7 Not used Do not change the settings Communication Switch 1D Not used do not change the settings Communication Switch 1E Not used do not change the settings Communication Switch 1F Not used do...

Страница 498: ...ker is on up to phase B in the T 30 protocol 1 0 Used for testing The monitor speaker is on all through the communication Make sure that you reset these bits after testing 2 Monitor speaker during memory transmission 0 Disabled 1 Enabled 1 The monitor speaker is enabled during memory transmission 3 5 Not used Do not change the settings 6 Private G3 FAX line enabled disabled switch 0 Disabled 1 Ena...

Страница 499: ...utput 0 Off 1 On Forbid output Do not change this setting Default 0 Off unless communication problem is caused by a CED or ANSam transmission 7 Not used Do not change the setting G3 Switch 02 SP No 1 105 003 No FUNCTION COMMENTS 0 G3 protocol mode used 0 Standard and non standard 1 Standard only Change this bit to 1 only when the other end can only communicate with machines that send T 30 standard...

Страница 500: ... slow down the data rate to 14 4 kbps or lower 3 ECM frame size 0 256 bytes 1 64 bytes Keep this bit at 0 in most cases 4 CTC transmission conditions 0 After one PPR signal received 1 After four PPR signals received ITU T standard 0 When using ECM in non standard NSF NSS mode the machine sends a CTC to drop back the modem rate after receiving a PPR if the following condition is met in communicatio...

Страница 501: ...ange the settings 7 Select detection of reverse polarity in ringing 0 Off 1 On This switch is used to prevent reverse polarity in ringing on the phone line applied to PSTN G3 ringing Do not change this setting 0 No detection Outside Japan 1 Detection Inside Japan only G3 Switch 04 SP No 1 105 005 No FUNCTION COMMENTS 0 3 Training error detection threshold 0 F Hex 0 15 bits If the number of error b...

Страница 502: ...ference V 8 protocol on off G3 switch 03 bit2 Bit 3 Bit 2 Bit 1 Bit 0 bps 0 0 0 1 2 4k 0 0 1 0 4 8k 0 0 1 1 7 2k 0 1 0 0 9 6k 0 1 0 1 12 0k 0 1 1 0 14 4k 0 1 1 1 16 8k 1 0 0 0 19 2k 1 0 0 1 21 6k 1 0 1 0 24 0k 1 0 1 1 26 4k 1 1 0 0 28 8k 1 1 0 1 31 2k 1 1 1 0 33 6k Other settings Not used 4 5 Initial modem type for 9 6 k or 7 2 kbps Bit 5 0 Bit 4 0 V 29 Bit 5 0 Bit 4 1 V 17 Bit 5 1 Bit 4 0 V 34 Bi...

Страница 503: ... if high speeds pose problems during reception If a modem rate 14 4 kbps or slower is selected V 8 protocol should be disabled manually Cross reference V 8 protocol on off G3 switch 03 bit2 Bit 3 Bit 2 Bit 1 Bit 0 bps 0 0 0 1 2 4k 0 0 1 0 4 8k 0 0 1 1 7 2k 0 1 0 0 9 6k 0 1 0 1 12 0k 0 1 1 0 14 4k 0 1 1 1 16 8k 1 0 0 0 19 2k 1 0 0 1 21 6k 1 0 1 0 24 0k 1 0 1 1 26 4k 1 1 0 0 28 8k 1 1 0 1 31 2k 1 1 ...

Страница 504: ...l of the available modem type for the machine in receive mode If V 34 is not selected V 8 protocol must be disabled manually Cross reference V 8 protocol on off G3 switch 03 bit2 Bit 7 Bit 6 Bit 5 Bit 4 Setting 0 0 0 1 V 27ter 0 0 1 0 V 27ter V 29 0 0 1 1 V 27ter V 29 0 1 0 0 V 27ter V 29 V 17 0 1 0 1 V 27ter V 29 V 17 V 34 Other settings Not used ...

Страница 505: ...lowing symptoms occurs Communication error Modem rate fallback occurs frequently This setting is not effective in V 34 communications 2 3 PSTN cable equalizer rx mode Internal Bit 3 0 Bit 2 0 None Bit 3 0 Bit 2 1 Low Bit 3 1 Bit 2 0 Medium Bit 3 1 Bit 2 1 High Use a higher setting if there is signal loss at higher frequencies because of the length of wire between the modem and the telephone exchan...

Страница 506: ...3 Switch 08 Not used do not change the settings G3 Switch 09 SP No 1 105 008 No FUNCTION COMMENTS 0 1 ISDN cable equalizer tx mode Internal Bit 1 0 Bit 0 0 None Bit 1 0 Bit 0 1 Low Bit 1 1 Bit 0 0 Medium Bit 1 1 Bit 0 1 High Use a higher setting if there is signal loss at higher frequencies because of the length of wire between the modem and the telephone exchange Use the dedicated transmission pa...

Страница 507: ...equently This setting is not effective in V 34 communications 4 ISDN cable equalizer V 8 V 17 rx mode External 0 Disabled 1 Enabled Keep this bit at 1 5 7 Not used Do not change the settings G3 Switch 0A SP No 1 105 011 No FUNCTION COMMENTS 0 1 Maximum allowable carrier drop during image data reception ms Bit 1 0 Bit 0 0 200 Bit 1 0 Bit 0 1 400 Bit 1 1 Bit 0 0 800 Bit 1 1 Bit 0 1 Reserved These bi...

Страница 508: ...hange the settings 6 Reconstruction time for the first line in receive mode 0 6 sec 1 12 sec When the sending terminal is controlled by a computer there may be a delay in receiving page data after the local machine accepts set up data and sends CFR This is outside the T 30 recommendation But if this delay occurs set this bit to 1 to give the sending machine more time to send data Refer to error co...

Страница 509: ...t4 1 Bit5 0 DP 10PPS fixed Bit4 1 Bit5 1 DP 20PPS fixed Sets the signal from the handset as a trigger for remote switching 6 7 Not used Do not change the settings G3 Switch 0D Not used do not change the settings G3 Switch 0E SP No 1 105 015 0 7 Set CNG send time interval Some machines on the receiving side may not be able to automatically switch the 3 second CNG interval High order bit 3000 2250ms...

Страница 510: ...t to 1 1 Alarm when the handset is off hook at the end of communication 0 Disabled 1 Enabled If the customer wants to hear an alarm if the handset is off hook at the end of fax communication change this bit to 1 2 3 Not used Do not change the settings 4 Sidaa manual calibration setting 0 Off 1 On 1 manually calibrates for communication with a line whose current change occurs such as an optical fib...

Страница 511: ...e communication via the gatekeeper for IP Fax 5 IP Fax T30 bit signal reverse 0 LSB first 1 MSB first Reverses the T30 bit signal 6 IP Fax max bit rate setting 0 Not affected 1 Affected When 0 is selected the max bit rate does not affect the value of the DIS DCS When 1 is selected the max bit rate affects the value of the DIS DCS 7 IP Fax received telephone number confirmation 0 No confirmation 1 ...

Страница 512: ... 0 Level 2 0 0 1 1 Level 3 4 7 IP Fax preamble wait time setting Selects the preamble wait time 00 to 0F There are 16 values in this 4 bit binary switch combination Waiting time set value level x 100 ms Max 0F 1500 ms Min 00 No wait time The default is 0000 00H IP Fax Switch 02 SP No 1 111 003 No FUNCTION COMMENTS 0 IP Fax bit signal reverse setting 0 Maker code setting 1 Internal bit switch setti...

Страница 513: ... 4 Message reception selection from non registered SIP server 0 Answer 1 Not answer 0 This answers the INVITE message from the SIP server not registered for the machine 1 This does not receive the INVITE message from the SIP server not registered for the machine and send a refusal message 5 ECM communication setting 0 No limit for image compression 1 Limit for image compression 0 This does not lim...

Страница 514: ...t used Do not change this setting 3 ECM frame size selection at transmitting 0 256byte 1 64byte Selects the ECM frame size for sending 4 DIS detection times for echo prevention 0 1 time 1 2 times Sets the number of times for DIS to detect echoes 5 CTC transmission selection 0 PPRx1 1 PPRx4 When 0 is selected the transmission condition is decided by error frame numbers When 1 is selected the transm...

Страница 515: ...e these settings IP Fax Switch 05 SP No 1 111 006 No FUNCTION COMMENTS 0 3 Modem bit rate setting for transmission Sets the modem bit rate for transmission The default is 0110 14 4K bps Bit 4 Bit 3 Bit 2 Bit 1 0 0 0 1 2400 bps 0 0 1 1 4800 bps 0 0 1 1 7200 bps 0 1 0 0 9600 bps 0 1 0 1 12 0 Kbps 0 1 1 0 14 4 Kbps 0 1 1 1 Not Used 1 0 0 0 Not Used 1 0 0 1 Not Used 1 0 1 0 Not Used 1 0 1 1 Not Used 1...

Страница 516: ...ication 6 7 Not used Do not change these settings IP Fax Switch 06 SP No 1 111 007 No FUNCTION COMMENTS 0 3 Modem bit rate setting for reception Sets the modem bit rate for reception The default is 0110 14 4K bps Bit 3 Bit 2 Bit 1 Bit 0 0 0 0 1 2400 bps 0 0 1 0 4800 bps 0 0 1 1 7200 bps 0 1 0 0 9600 bps 0 1 0 1 12 0 Kbps 0 1 1 0 14 4 Kbps 0 1 1 1 Not Used 1 0 0 0 Not Used 1 0 0 1 Not Used 1 0 1 0 ...

Страница 517: ...tion IP Fax Switch 07 SP No 1 111 008 No FUNCTION COMMENTS 0 TSI information 0 Not added 1 Added Adds or does not add TSI information to NSS S 1 DCN transmission setting at T1 timeout 0 Not transmitted 1 Transmitted Transmits or does not transmit DCN at T1 timeout 2 Not used Do not change this setting 3 Hang up setting at DIS reception disabled 0 No hang up 1 Hang up after transmitting DCN Sets wh...

Страница 518: ...0 1 40 sec Bit 1 1 Bit 0 0 50 sec Bit 1 1 Bit 0 1 60 sec 2 3 T4 timer adjustment Adjust the T4 timer The default is 00 3 seconds Bit 3 0 Bit 2 0 3 sec Bit 3 0 Bit 2 1 3 5 sec Bit 3 1 Bit 2 0 4 sec Bit 3 1 Bit 2 1 5 sec 4 5 T0 timer adjustment Bit 5 0 Bit 4 0 75 sec Bit 5 0 Bit 4 1 120 sec Bit 5 1 Bit 4 0 180 sec Bit 5 1 Bit 4 1 240 sec Adjusts the fail safe timer This timer sets the interval betwe...

Страница 519: ...n is done 0 The same method as the call connection 1 Automatic setting Sets selection way of network I F method Automatic setting 1 means negotiating with call connection before determining IPv4 or IPv6 2 Record route using 1 Enabled 2 Disabled Enabled is for Record route acceptable SIP server 3 4 Delay time between ACK message reception and re INVITE transmitting Set this function more than 1 sec...

Страница 520: ...68 SM Appendix IP Fax Switch 0A Not Used do not change the settings IP Fax Switch 0B Not Used do not change the settings IP Fax Switch 0C Not Used do not change the settings IP Fax Switch 0D Not Used do not change the settings ...

Страница 521: ... will be indicated in the Remarks column The RAM is programmed in hex code unless BCD is included in the Unit column Address Function 680500 Country Area code for NCU parameters Use the Hex value to program the country area code directly into this address or use the decimal value to program it using SP2 103 001 Country Area Decimal Hex Country Area Decimal Hex France 00 00 USA 17 11 Germany 01 01 ...

Страница 522: ...e current drop detect time 680504 PSTN dial tone frequency upper limit high byte Hz BCD If both addresses contain FF H tone detection is disabled 680505 PSTN dial tone frequency upper limit low byte 680506 PSTN dial tone frequency lower limit high byte Hz BCD If both addresses contain FF H tone detection is disabled 680507 PSTN dial tone frequency lower limit low byte 680508 PSTN dial tone detecti...

Страница 523: ...or silent period after ring back tone detected HIGH 20 ms 680513 PSTN busy tone frequency upper limit high byte Hz BCD If both addresses contain FF H tone detection is disabled 680514 PSTN busy tone frequency upper limit low byte 680515 PSTN busy tone frequency lower limit high byte Hz BCD If both addresses contain FF H tone detection is disabled 680516 PSTN busy tone frequency lower limit low byt...

Страница 524: ...k tone detection time 20 ms If both addresses contain FF H tone detection is disabled 680523 PABX ringback tone off detection time 20 ms 680524 PABX detection time for silent period after ringback tone detected LOW 20 ms If both addresses contain FF H tone detection is disabled 680525 PABX detection time for silent period after ringback tone detected HIGH 20 ms 680526 PABX busy tone frequency uppe...

Страница 525: ...s means that ON OFF ON or OFF ON OFF must be detected twice Tolerance Bit 1 0 Bit 0 0 75 Bits 2 and 3 must always be kept at 0 Bit 1 0 Bit 0 0 50 Bits 2 and 3 must always be kept at 0 Bit 1 0 Bit 0 0 25 Bit 1 0 Bit 0 0 12 5 Bits 7 6 5 4 number of cycles required for cadence detection 680534 International dial tone frequency upper limit high byte Hz BCD If both addresses contain FF H tone detection...

Страница 526: ...ntry dial tone upper frequency limit HIGH Hz BCD If both addresses contain FF H tone detection is disabled 680540 Country dial tone upper frequency limit LOW 680541 Country dial tone lower frequency limit HIGH If both addresses contain FF H tone detection is disabled 680542 Country dial tone lower frequency limit LOW 680543 Country dial tone detection time 20 ms If 680543 contains FF the machine p...

Страница 527: ...s See Note 3 SP2 103 014 parameter 13 68054D Time between final OHDI relay closure and DO relay opening or closing 1 ms See Notes 3 6 and 8 SP2 103 015 parameter 14 This parameter is only valid in Europe 68054E Minimum pause between dialed digits pulse dial mode 20 ms See Note 3 and 8 SP2 103 016 parameter 15 68054F Time waited when a pause is entered at the operation panel SP2 103 017 parameter 1...

Страница 528: ...ee Note 5 680555 ISDN DTMF tone attenuation level after dialling dBm x 0 5 See Note 5 680556 Not used Do not change the settings 680557 Time between 68054Dh NCU parameter 14 and 68054Eh NCU parameter 15 1 ms This parameter takes effect when the country code is set to France 680558 Not used Do not change the setting 680559 Grounding time ground start mode 20 ms The Gs relay is closed for this inter...

Страница 529: ...it 5 0 30 0 dBm Bit 7 1 Bit 6 0 Bit 5 0 40 0 dBm Bit 7 1 Bit 6 1 Bit 5 0 49 0 dBm Bits 2 0 See Note 2 68055F To 680564 Not used Do not change the settings 680565 Long distance call prefix HIGH BCD For a code of 0 680565 FF 680566 FF 680566 Long distance call prefix LOW BCD 680567 to 680571 Not used Do not change the settings 680572 Acceptable ringing signal frequency range 1 upper limit 1000 N Hz ...

Страница 530: ...reset time LOW 20 ms SP2 103 010 parameter 09 68057A Ringing signal detection reset time HIGH SP2 103 011 parameter 10 68057B to 680580 Not used Do not change the settings 680581 Interval between dialing the last digit and switching the Oh relay over to the external telephone when dialing from the operation panel in handset mode 20 ms Factory setting 500 ms 680582 Bits 0 and 1 Handset off hook det...

Страница 531: ...requency lower limit low byte 6805A5 CED detection time 20 ms 20 ms Factory setting 200 ms 6805A6 Acceptable CNG detection frequency upper limit high byte BCD Hz If both addresses contain FF H tone detection is disabled 6805A7 Acceptable CNG detection frequency upper limit low byte 6805A8 Acceptable CNG detection frequency lower limit high byte BCD Hz If both addresses contain FF H tone detection ...

Страница 532: ...F H tone detection is disabled 6805B2 Acceptable AI short protocol tone 800Hz detection frequency lower limit low byte 6805B3 Detection time for 800 Hz AI short protocol tone 20 ms Factory setting 360 ms 6805B4 PSTN Tx level from the modem N 3 dBm SP2 103 002 parameter 01 6805B5 PSTN 1100 Hz tone transmission level N 6805B4 0 5N 6805B5 3 5 dB See Note 7 6805B6 PSTN 2100 Hz tone transmission level ...

Страница 533: ...Maximum wait time for post message EOP EOM MPS can be changed to 30 s Change this bit to 1 if communication errors occur frequently during V 17 reception 6805E4 Bit 2 sets the level of the call signal Bit 3 sets the call signal impedance Bit 2 0 RT 0 Low 1 RT 1 High Bit 3 0 RZ 0 High 1 RZ 1 Composite 6805E5 Bit 0 sets the ring detection method Bit 1 sets the ring detection method when fixed Bit 0 ...

Страница 534: ...ly compensates 4 The first ring may not be detected until 1 to 2 5 wavelengths after the time specified by this parameter 5 The calculated level must be between 0 and 10 The attenuation levels calculated from RAM data are High frequency tone 0 5 x N680552 680554 3 5 dBm 0 5 x N680555 dBm Low frequency tone 0 5 x N680552 680554 N680553 3 5 dBm 0 5 x N680555 N680553 dBm N680552 for example means the...

Страница 535: ...will be described 5 4 1 PROGRAMMING PROCEDURE 1 Set the bit 0 of System Bit Switch 00 to 1 01H 2 Enter Address Book Management mode User Tools Address Book Management 3 Select New program To create the new address book or Change To change already created address book 4 Press the Fax Dest or Email and select Fax Dest for the fax parameter or select Email for E mail 5 Press Start key Make sure that ...

Страница 536: ... byte in hex code multiplied by 1 second Range 0 to 120 s 00h to 78h FFh The local NCU parameter factory setting is used Do not program a value between 79h and FEh Switch 01 No FUNCTION COMMENTS 0 4 Tx level If communication with a particular remote terminal often contains errors the signal level may be inappropriate Adjust the Tx level for communications with that terminal until the results are b...

Страница 537: ...gher setting if there is signal loss at higher frequencies because of the length of wire between the modem and the telephone exchange when calling the number stored in this Quick Speed Dial Also try using the cable equalizer if one or more of the following symptoms occurs Communication error with error codes such as 0 20 0 23 etc Modem rate fallback occurs frequently Do not use settings other than...

Страница 538: ...l Tx modem rate using these bits For the settings 14 4 or kbps slower Switch 04 bit 4 must be changed to 0 Do not use settings other than listed on the left If the setting is Disabled the bit switch setting is used Bit3 Bit2 Bit1 Bit0 bps 0 0 0 0 Not used 0 0 0 1 2400 0 0 1 0 4800 0 0 1 1 7200 0 1 0 0 9600 0 1 0 1 12000 0 1 1 0 14400 1 1 0 1 31200 1 1 1 0 33600 1 1 1 1 Disabled Other settings Not ...

Страница 539: ...ll then wait for the second DIS or NSF before sending DCS or NSS If the setting is Disabled the bit switch setting is used 4 V 8 protocol 0 Off 1 Disabled If transmissions to a specific destination always end at a lower modem rate 14 400 bps or lower disable V 8 protocol so as not to use V 34 protocol 0 V 34 communication will not be possible If the setting is Disabled the bit switch setting is us...

Страница 540: ... initial settings of the following e mail parameters are all 0 all parameters disabled Switch 00 No FUNCTION COMMENTS 0 MH Compression mode for e mail attachments 0 Off 1 On Switches MH compression on and off for files attached to e mails for sending 1 MR Compression mode for e mail attachments 0 Off 1 On Switches MR compression on and off for files attached to e mails for sending 2 MMR Compressio...

Страница 541: ...th of e mail attachment A4 0 Off 1 On Sets the original width of the e mail attachment as A4 1 Original width of e mail attachment B4 0 Off 1 On Sets the original width of the e mail attachment as B4 2 Original width of e mail attachment A3 0 Off 1 On Sets the original width of the e mail attachment as A3 3 6 Not used Do not change these settings 7 Designates the bits to reference for original siz...

Страница 542: ... e mail attachment 200 x 400 0 Off 1 On Sets the line resolution of the e mail attachment as 200 x 400 3 Not used Do not change these settings 4 Line resolution of e mail attachment 400 x 400 0 Off 1 On Sets the line resolution of the e mail attachment as 400 x 400 5 6 Not used Do not change these settings 7 Designates the bits to reference for original size of e mail attachments 0 Registered Bit ...

Страница 543: ...This machine attaches the demand of reception confirmation to a message when transmitting This machine updates the reception capability to the address book when receiving 1 7 Not used Do not change these settings Switch 05 No FUNCTION COMMENTS 0 Direct transmission selection to SMTP server 0 ON 1 OFF Allows or does not allow the direct transmission to SMTP server 1 7 Not used Do not change these s...

Страница 544: ...D661 PAPER FEED UNIT PB1040 REVISION HISTORY Page Date Added Updated New None ...

Страница 545: ......

Страница 546: ...ER TRAY UNIT 1 1 1 1 PAPER TRAY UNIT 1 If optional tray heater is not installed 1 If optional tray heater is installed 1 1 1 2 FEED ROLLER AND FRICTION PAD 2 1 2 SENSORS 3 1 3 DRIVE 4 1 3 1 COOLING FAN 4 1 3 2 DRIVE BRACKET AND PAPER FEED CLUTCH 5 1 3 3 PAPER FEED MOTOR 5 1 3 4 TRAY MAIN BOARD 6 ...

Страница 547: ......

Страница 548: ...llation on the Field Service Manual and do following Unscrew the ground line Unclamp the heater harness clamps Disconnect the heater harness clamps Unwrap and remove the core 2 Pull the relay harness down and out through the hole in the PSU bracket and then pull it all the way in through the hole at the rear of the main paper tray unit 3 Lift the copier off the paper tray unit To reinstall refer t...

Страница 549: ...Paper Tray Unit D661 2 SM 1 1 2 FEED ROLLER AND FRICTION PAD 1 Take the tray out of the paper tray unit 2 Clip ring A 3 Shaft assembly B 4 feed roller C x 1 5 Friction pad D ...

Страница 550: ...d Unit PB1040 D661 1 2 SENSORS 1 Remove the paper tray unit from the copier p 1 Paper Tray Unit 2 Open the PTU s right door A 3 PTU s upper cover B x 2 4 Paper end sensor C x 2 x 1 Hook 5 Paper feed sensor D feeler E x 1 x 1 Hook ...

Страница 551: ...Drive D661 4 SM 1 3 DRIVE 1 3 1 COOLING FAN 1 Remove the paper tray unit from the copier p 1 Paper Tray Unit 2 Detach the fan bracket A x 2 x 1 3 Cooling fan B x 2 ...

Страница 552: ... PB1040 D661 1 3 2 DRIVE BRACKET AND PAPER FEED CLUTCH 1 Drive Bracket A x 3 x 2 x 1 2 Paper Feed Clutch B 1 3 3 PAPER FEED MOTOR 1 Drive Bracket and Paper Feed Clutch p 5 Drive Bracket and Paper Feed Clutch 2 Paper Feed Motor A x 2 ...

Страница 553: ...Drive D661 6 SM 1 3 4 TRAY MAIN BOARD 1 Tray main board A x 4 all connectors Be sure not to reinstall the board upside down ...

Отзывы: